Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 8 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
477new WordPress flaws this week
390,525entries in the database

13 results

  • Jan 31, 2023 A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the CVE-2023-22610 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.

    Product
    EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 29, 2022Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization.CVE-2021-43938 · Other software · Elcomplus · reported by ics-cert@hq.dhs.govHigh 8.1

    Elcomplus SmartPTT SCADA Server is vulnerable to an unauthenticated user can request various files from the server without any authentication or authorization.

    Product
    SmartPTT SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 29, 2022Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provCVE-2021-43937 · Other software · Elcomplus · reported by ics-cert@hq.dhs.govHigh 7.6

    Elcomplus SmartPTT SCADA Server web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.

    Product
    SmartPTT SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to eCVE-2022-21155 · Other software · Fernhill · reported by ics-cert@hq.dhs.govHigh 7.5

    A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit.

    Product
    SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 9, 2022A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receivCVE-2022-24321 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

    Product
    Clearscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2020A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versCVE-2020-6970 · Other software · Emerson · reported by ics-cert@hq.dhs.govCritical 9.8

    A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.

    Product
    OpenEnterprise SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2015Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default instCVE-2015-0990 · Other software · Ecava · reported by ics-cert@hq.dhs.govMedium 4.4

    Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory.

    Product
    Integraxor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 15, 2014Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to discover full pathnames via an application taCVE-2014-2377 · Other software · Ecava · reported by ics-cert@hq.dhs.govMedium 5

    Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to discover full pathnames via an application tag.

    Product
    IntegraXor SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 15, 2014SQL injection vulnerability in Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to execute arbitrCVE-2014-2376 · Other software · Ecava · reported by ics-cert@hq.dhs.govHigh 7.5

    SQL injection vulnerability in Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

    Product
    IntegraXor SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 15, 2014Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrary files, and obtain CVE-2014-2375 · Other software · Ecava · reported by ics-cert@hq.dhs.govHigh 8.3

    Ecava IntegraXor SCADA Server Stable 4.1.4360 and earlier and Beta 4.1.4392 and earlier allows remote attackers to read or write to arbitrary files, and obtain sensitive information or cause a denial of service (disk consumption), via the CSV export feature.

    Product
    IntegraXor SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 20, 2014Stack-based buffer overflow in the SCADA server in Ecava IntegraXor before 4.1.4390 allows remote attackers to cause a denial of service (system crash) by triggCVE-2014-0753 · Other software · Ecava · reported by ics-cert@hq.dhs.govHigh 7.8

    Stack-based buffer overflow in the SCADA server in Ecava IntegraXor before 4.1.4390 allows remote attackers to cause a denial of service (system crash) by triggering access to DLL code located in the IntegraXor directory.

    Product
    IntegraXor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 9, 2014The SCADA server in Ecava IntegraXor before 4.1.4369 allows remote attackers to read arbitrary project backup files via a crafted URL.CVE-2014-0752 · Other software · Ecava · reported by ics-cert@hq.dhs.govHigh 7.5

    The SCADA server in Ecava IntegraXor before 4.1.4369 allows remote attackers to read arbitrary project backup files via a crafted URL.

    Product
    IntegraXor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 8, 2013Multiple buffer overflows in an ActiveX control in PE3DO32A.ocx in IntegraXor SCADA Server 4.00 build 4250.0 and earlier allow remote attackers to execute arbitCVE-2012-4700 · Other software · Ecava · reported by ics-cert@hq.dhs.govHigh 9.3

    Multiple buffer overflows in an ActiveX control in PE3DO32A.ocx in IntegraXor SCADA Server 4.00 build 4250.0 and earlier allow remote attackers to execute arbitrary code via a crafted HTML document.

    Product
    Integraxor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.