Sep 29, 2026An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot thrCVE-2026-8067 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.5
An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot through the reset endpoint. Successful exploitation could cause temporary device unavailability and disruption of its intended operation.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Sep 29, 2026A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write oCVE-2026-8066 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comCritical 9.1
A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Sep 29, 2026An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to uploaCVE-2026-8065 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comCritical 9.1
An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to upload arbitrary firmware through a crafted POST request. Successful exploitation could allow the attacker to modify device functionality or compromise the integrity or availability of the device.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Sep 3, 2026RTU500 has a vulnerability, where high-load scenarios, such as sending GI requests at short intervals, may cause a NULL pointer dereference in the last entry ofCVE-2026-17539 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9
RTU500 has a vulnerability, where high-load scenarios, such as sending GI requests at short intervals, may cause a NULL pointer dereference in the last entry of the enhanced message queue. This can cause a BCI_IEC104 fatal write error, resulting in connection interruption and restart, and ultimately a denial of service for bidirectional IEC 60870-5-104 communication.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
May 26, 2026IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable for a NULL pointer dereferencing, if a specially crafted sequence of messages is sent for a cCVE-2026-8479 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.9
IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable for a NULL pointer dereferencing, if a specially crafted sequence of messages is sent for a certain time, causing Denial of Service impact. Product is only affected if IEC 60870-5-104 functionality in bidirectional mode (BCI) is configured.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Feb 24, 2026IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame.CVE-2026-1773 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.7
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Feb 24, 2026RTU500 web interface: An unprivileged user can read user management information.CVE-2026-1772 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.3
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Mar 25, 2025A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection tCVE-2025-1445 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.7
A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are configured using TLS on RTU500 device. It affects the CMU the IEC61850 stack is configured on.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Mar 25, 2025A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attCVE-2024-12169 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.7
A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Mar 25, 2025A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restartCVE-2024-11499 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.9
A vulnerability exists in RTU500 IEC 60870-4-104 controlled station functionality, that allows an authenticated and authorized attacker to perform a CMU restart. The vulnerability can be triggered if certificates are updated while in use on active connections. The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Mar 25, 2025A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequenCVE-2024-10037 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9
A vulnerability exists in the RTU500 web server component that can cause a denial of service to the RTU500 CMU application if a specially crafted message sequence is executed on a WebSocket connection. An attacker must be properly authenticated and the test mode function of RTU500 must be enabled to exploit this vulnerability. The affected CMU will automatically recover itself if an attacker successfully exploits this vulnerability.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.com
Apr 30, 2024A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update, if secure update feature was not enabled on aCVE-2024-2617 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.2
A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update, if secure update feature was not enabled on all CMUs of a RTU500. If a malicious actor successfully exploits this vulnerability, they could use it to update the RTU500 with unsigned firmware.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Mar 26, 2024A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below.CVE-2024-1532 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.8
A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could enforce diagnostic texts being displayed as empty strings, if an authorized user uploads a specially crafted stb-language file.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Mar 26, 2024A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below.CVE-2024-1531 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.2
A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could print random memory content in the RTU500 system log, if an authorized user uploads a specially crafted stb-language file.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Jan 4, 2024A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above.CVE-2022-2081 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.
- Product
- RTU500 series CMU firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Dec 19, 2023Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.CVE-2023-6711 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9
Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU500 CMU.
- Product
- RTU500 series CMU Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Dec 19, 2023A vulnerability exists in the component RTU500 Scripting interface.CVE-2023-1514 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.4
A vulnerability exists in the component RTU500 Scripting interface. When a client connects to a server using TLS, the server presents a certificate. This certificate links a public key to the identity of the service and is signed by a Certification Authority (CA), allowing the client to validate that the remote service can be trusted and is not malicious. If the client does not validate the parameters of the certificate, then attackers could be able to spoof the identity of the service. An attacker could exploit the vulnerability by using faking the identity of a RTU500 device and intercepting the messages initiated via the RTU500 Scripting interface.
- Product
- RTU500 Scripting Interface
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Dec 14, 2023 A vulnerability exists in the webserver that affects the RTU500 series product versions listed below.CVE-2023-5769 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.4
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Dec 4, 2023A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.CVE-2023-5768 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
- Product
- RTU500 series
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Dec 4, 2023 A vulnerability exists in the webserver that affects the RTU500 series product versions listed below.CVE-2023-5767 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized.
- Product
- RTU500
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.compublisher.hitachienergy.com
Jul 26, 2023A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product.CVE-2022-4608 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-3. After session resumption interval is expired an RTU500 initiated update of session parameters causes an unexpected restart due to a stack overflow.
- Product
- RTU500 series
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.comsearch.abb.com
Jul 26, 2023A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product.CVE-2022-2502 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5
A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.
- Product
- RTU500 series
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.comsearch.abb.com
May 2, 2022A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above.CVE-2022-28613 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.
- Product
- RTU500 series CMU Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpublisher.hitachienergy.comsearch.abb.com
Nov 26, 2021Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 CVE-2021-35533 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).
- Product
- RTU500 series
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsearch.abb.comsearch.abb.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.