Feb 15, 2018A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12726 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govHigh 7.3
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12725 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govMedium 5.6
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12724 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govHigh 8.1
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12723 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govLow 3.7
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12722 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govMedium 5.3
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecurityfocus.com
Feb 15, 2018An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12721 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govMedium 5.9
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12720 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govHigh 8.1
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 15, 2018A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.CVE-2017-12718 · Other software · Smiths-medical · reported by ics-cert@hq.dhs.govHigh 8.1
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
- Product
- Medfusion 4000 Wireless Syringe Infusion Pump
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecurityfocus.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.