Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 8 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
456new WordPress flaws this week
390,714entries in the database

37 results

  • Feb 10, 2025Certain models of routers from Billion Electric has hard-coded embedded linux credentials, allowing attackers to log in through the SSH service using these credCVE-2025-1143 · Other software · Billion Electric · reported by twcert@cert.org.twHigh 8.4

    Certain models of routers from Billion Electric has hard-coded embedded linux credentials, allowing attackers to log in through the SSH service using these credentials and obtain root privilege of the system.

    Product
    M100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 29, 2024Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbCVE-2024-11983 · Other software · Billion Electric · reported by twcert@cert.org.twHigh 7.2

    Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific SSH function and execute them on the device.

    Product
    M100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 29, 2024Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability.CVE-2024-11982 · Other software · Billion Electric · reported by twcert@cert.org.twHigh 7.2

    Certain models of routers from Billion Electric has a Plaintext Storage of a Password vulnerability. Remote attackers with administrator privileges can access the user settings page to retrieve plaintext passwords.

    Product
    M100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 29, 2024Certain models of routers from Billion Electric has an Authentication Bypass vulnerability, allowing unautheticated attackers to retrive contents of arbitrary wCVE-2024-11981 · Other software · Billion Electric · reported by twcert@cert.org.twHigh 7.5

    Certain models of routers from Billion Electric has an Authentication Bypass vulnerability, allowing unautheticated attackers to retrive contents of arbitrary web pages.

    Product
    M100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 29, 2024Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the speCVE-2024-11980 · Other software · Billion Electric · reported by twcert@cert.org.twHigh 8.6

    Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device.

    Product
    M100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 28, 2023 Saho’s attendance devices ADM100 and ADM-100FP have a vulnerability of missing authentication for critical functions.CVE-2023-38030 · Other software · Saho · reported by twcert@cert.org.twHigh 7.5

    Saho’s attendance devices ADM100 and ADM-100FP have a vulnerability of missing authentication for critical functions. An unauthenticated remote attacker can execute system commands in partial website URLs to read sensitive device information without permissions.

    Product
    ADM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 28, 2023 Saho’s attendance devices ADM100 and ADM-100FP has insufficient filtering for special characters and file type within their file uploading function.CVE-2023-38029 · Other software · Saho · reported by twcert@cert.org.twCritical 9.8

    Saho’s attendance devices ADM100 and ADM-100FP has insufficient filtering for special characters and file type within their file uploading function. A unauthenticate remote attacker authenticated can upload and execute arbitrary files to perform arbitrary system commands or disrupt service.

    Product
    ADM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 28, 2023 Saho’s attendance devices ADM100 and ADM-100FP have insufficient authentication.CVE-2023-38028 · Other software · Saho · reported by twcert@cert.org.twCritical 9.1

    Saho’s attendance devices ADM100 and ADM-100FP have insufficient authentication. An unauthenticated remote attacker can exploit this vulnerability to bypass authentication to read system information and operate user's data, but can’t control system or disrupt service.

    Product
    ADM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the CVE-2023-25912 · Other software · Danfoss · reported by csirt@divd.nlMedium 5.3

    The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the internal IP address, usernames and internal device values.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.CVE-2023-25911 · Other software · Danfoss · reported by csirt@divd.nlCritical 9.9

    The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter.CVE-2023-22586 · Other software · Danfoss · reported by csirt@divd.nlHigh 7.7

    The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter.CVE-2023-22585 · Other software · Danfoss · reported by csirt@divd.nlCritical 9

    The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 stores login credentials in cleartext.CVE-2023-22584 · Other software · Danfoss · reported by csirt@divd.nlHigh 7.5

    The Danfoss AK-EM100 stores login credentials in cleartext.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.CVE-2023-22583 · Other software · Danfoss · reported by csirt@divd.nlCritical 10

    The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2023The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting.CVE-2023-22582 · Other software · Danfoss · reported by csirt@divd.nlCritical 9

    The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting.

    Product
    AK-EM100
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 1, 2022Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the useCVE-2022-27586 · Other software · Sick · reported by psirt@sick.deCritical 9.8

    Password recovery vulnerability in SICK SIM1004 Partnumber 1098148 with firmware version <2.0.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.0.0 as soon as possible (available in SICK Support Portal).

    Product
    Sim1004-0p0g311 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 1, 2022Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain acCVE-2022-27585 · Other software · Sick · reported by psirt@sick.deCritical 9.8

    Password recovery vulnerability in SICK SIM1000 FX Partnumber 1097816 and 1097817 with firmware version <1.6.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.6.0 as soon as possible (available in SICK Support Portal).

    Product
    Sim1000 FX Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 28, 2022Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host ECVE-2022-3228 · Other software · Host Engineering · reported by ics-cert@hq.dhs.govMedium 6.5

    Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive.

    Product
    H0-ECOM100 Communications Module
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 17, 2021A privilege escalation vulnerability was reported in the MM1000 device configuration web server, which could allow privileged shell access and/or arbitrary privCVE-2021-3459 · Other software · Motorola · reported by psirt@lenovo.comMedium 6.8

    A privilege escalation vulnerability was reported in the MM1000 device configuration web server, which could allow privileged shell access and/or arbitrary privileged commands to be executed on the adapter.

    Product
    MM1000 MoCA Adapter
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 17, 2021The Motorola MM1000 device configuration portal can be accessed without authentication, which could allow adapter settings to be modified.CVE-2021-3458 · Other software · Motorola · reported by psirt@lenovo.comMedium 6.1

    The Motorola MM1000 device configuration portal can be accessed without authentication, which could allow adapter settings to be modified.

    Product
    MM1000 MoCA Adapter
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 15, 2020The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input fromCVE-2020-25195 · Other software · Hosteng · reported by ics-cert@hq.dhs.govHigh 7.5

    The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device.

    Product
    H0-ecom100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2020An issue was discovered on Nescomed Multipara Monitor M1000 devices.CVE-2020-15485 · Other software · Niscomed · reported by MITREMedium 5.5

    An issue was discovered on Nescomed Multipara Monitor M1000 devices. The onboard Flash memory stores data in cleartext, without integrity protection against tampering.

    Product
    M1000 Multipara Patient Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2020An issue was discovered on Nescomed Multipara Monitor M1000 devices.CVE-2020-15483 · Other software · Niscomed · reported by MITREMedium 6.8

    An issue was discovered on Nescomed Multipara Monitor M1000 devices. The physical UART debug port provides a shell, without requiring a password, with complete access.

    Product
    M1000 Multipara Patient Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2020An issue was discovered on Nescomed Multipara Monitor M1000 devices.CVE-2020-15482 · Other software · Niscomed · reported by MITREHigh 7.8

    An issue was discovered on Nescomed Multipara Monitor M1000 devices. The device enables an unencrypted TELNET service by default, with a blank password for the admin account. This allows an attacker to gain root access to the device over the local network.

    Product
    M1000 Multipara Patient Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2020An issue was discovered on Nescomed Multipara Monitor M1000 devices.CVE-2020-15484 · Other software · Niscomed · reported by MITREHigh 7.5

    An issue was discovered on Nescomed Multipara Monitor M1000 devices. The internal storage of the underlying Linux system stores data in cleartext, without integrity protection against tampering.

    Product
    M1000 Multipara Patient Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 20, 2020Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.CVE-2020-7240 · Other software · meinberg · reported by MITREHigh 8.8

    Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using 'Special Elements.

    Product
    ims-lantime_m1000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 22, 2019A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network maCVE-2019-6820 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.2

    A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2

    Product
    Modicon M100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2016The NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIME M600, LANTIME M400, LANTIME M300, LANTIMCVE-2016-3989 · Other software · Meinberg · reported by MITREHigh 8.1

    The NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIME M600, LANTIME M400, LANTIME M300, LANTIME M200, LANTIME M100, SyncFire 1100, and LCES devices with firmware before 6.20.004 allows remote authenticated users to obtain root privileges for writing to unspecified scripts, and consequently obtain sensitive information or modify data, by leveraging access to the nobody account.

    Product
    NTP Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2016Multiple stack-based buffer overflows in the NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIMECVE-2016-3988 · Other software · Meinberg · reported by MITREHigh 7.3

    Multiple stack-based buffer overflows in the NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIME M600, LANTIME M400, LANTIME M300, LANTIME M200, LANTIME M100, SyncFire 1100, and LCES devices with firmware before 6.20.004 allow remote attackers to obtain sensitive information, modify data, or cause a denial of service via a crafted parameter in a POST request.

    Product
    NTP Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2016Stack-based buffer overflow in the NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIME M600, LANCVE-2016-3962 · Other software · Meinberg · reported by MITREHigh 7.3

    Stack-based buffer overflow in the NTP time-server interface on Meinberg IMS-LANTIME M3000, IMS-LANTIME M1000, IMS-LANTIME M500, LANTIME M900, LANTIME M600, LANTIME M400, LANTIME M300, LANTIME M200, LANTIME M100, SyncFire 1100, and LCES devices with firmware before 6.20.004 allows remote attackers to obtain sensitive information, modify data, or cause a denial of service via a crafted parameter in a POST request.

    Product
    NTP Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 4, 2013The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenCVE-2013-0664 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 8.5

    The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.

    Product
    Modicon Quantum PLC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 4, 2013Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BCVE-2013-0663 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.8

    Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.

    Product
    Modicon Quantum PLC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2012The web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 allows remote attackeCVE-2012-1809 · Other software · Koyo · reported by cret@cert.orgMedium 5

    The web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 allows remote attackers to cause a denial of service (resource consumption) via unspecified vectors.

    Product
    H0-ecom
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2012The web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 does not require authCVE-2012-1808 · Other software · Koyo · reported by cret@cert.orgHigh 10

    The web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 does not require authentication, which allows remote attackers to perform unspecified functions via unknown vectors.

    Product
    H0-ecom
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2012Cross-site scripting (XSS) vulnerability in the web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-CVE-2012-1807 · Other software · Koyo · reported by cret@cert.orgMedium 4.3

    Cross-site scripting (XSS) vulnerability in the web server in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

    Product
    H0-ecom
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2012The ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 supports a maximum password length of 8CVE-2012-1806 · Other software · Koyo · reported by cret@cert.orgHigh 7.5

    The ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 supports a maximum password length of 8 bytes, which makes it easier for remote attackers to obtain access via a brute-force attack.

    Product
    H0-ecom
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2012Buffer overflow in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 allows remote attackCVE-2012-1805 · Other software · Koyo · reported by cret@cert.orgHigh 10

    Buffer overflow in the ECOM Ethernet module in Koyo H0-ECOM, H0-ECOM100, H2-ECOM, H2-ECOM-F, H2-ECOM100, H4-ECOM, H4-ECOM-F, and H4-ECOM100 allows remote attackers to execute arbitrary code via long strings in unspecified parameters.

    Product
    H0-ecom
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.