Jan 9, 2025There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargeCVE-2024-43663 · Other software · Iocharger · reported by csirt@divd.nlMedium 5.3
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require auth
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interCVE-2024-43662 · Other software · Iocharger · reported by csirt@divd.nlMedium 5.3
The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it. Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificates.CVE-2024-43661 · Other software · Iocharger · reported by csirt@divd.nlHigh 7.1
The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificates. This buffer overflow can be triggered by providing a long file path to the <redacted> action of the <redacted>.exe CGI binary or to the <redacted>.sh CGI script. This binary or script will write this file path to <redacted>, which is then read by <redacted>.so This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will have to find this exploit by either obtaining the binaries involved in this vulnerability, or by trial and error. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe CGI binary or <redacted>.sh script to trigger the vulnerability, or convince a user with such access send an HTTP request that triggers it. Impact: High – The <redacted> process, which we assume is responsible for OCPP communication, will keep crashing after performing the exploit. This happens because the buffer overflow causes the process to segfault before <redacted> is removed. This means that, even though <redacted> is automatically restarted, it wi
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025The CGI script <redacted>.sh can be used to download any file on the filesystem.CVE-2024-43660 · Other software · Iocharger · reported by csirt@divd.nlHigh 7.1
The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automate
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all IochCVE-2024-43659 · Other software · Iocharger · reported by csirt@divd.nlHigh 8.3
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any net
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmwareCVE-2024-43658 · Other software · Iocharger · reported by csirt@divd.nlHigh 7.2
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects IocharCVE-2024-43657 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects IocharCVE-2024-43656 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should pote
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects IocharCVE-2024-43655 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety imp
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command InjectiCVE-2024-43654 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromis
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects IocharCVE-2024-43653 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects IochargCVE-2024-43651 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to poten
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command InjectioCVE-2024-43650 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pi
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.CVE-2024-43649 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Jan 9, 2025Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.CVE-2024-43648 · Other software · Iocharger · reported by csirt@divd.nlCritical 9.3
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full sys
- Product
- Iocharger firmware for AC models
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcsirt.divd.nlcsirt.divd.nl
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.