6 results

  • Apr 14, 2020The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability.CVE-2020-7802 · Other software · S3india · reported by MITREMedium 5.3

    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorrect Default Permissions (CWE-276) vulnerability. The affected product is vulnerable to insufficient default permissions, which could allow an attacker to view network configurations through SNMP communication. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7801.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 14, 2020The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposure of Sensitive Information to an Unauthorized ActoCVE-2020-7801 · Other software · Mysyngeryss · reported by MITREMedium 5.3

    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposure of Sensitive Information to an Unauthorized Actor (CWE-200) vulnerability. The affected product is vulnerable to information exposure over the SNMP protocol. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7800, and CVE-2020-7802.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 14, 2020The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Improper Check for Unusual or Exceptional Conditions (CWECVE-2020-7800 · Other software · Mysyngeryss · reported by MITREHigh 8.2

    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability. The affected product is vulnerable to specially crafted TCP packets, which can cause the device to shut down or reboot and lose configuration settings. This is a different issue than CVE-2019-16879, CVE-2019-20045, CVE-2019-20046, CVE-2020-7801, and CVE-2020-7802.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 14, 2020The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulCVE-2019-16879 · Other software · Mysyngeryss · reported by MITRECritical 9.8

    The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 14, 2020The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior.CVE-2019-20046 · Other software · S3india · reported by MITRECritical 9.8

    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. The affected product does not require adequate authentication, which may allow an attacker to read sensitive information or execute arbitrary code. This is a different issue than CVE-2019-16879 and CVE-2019-20045.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 14, 2020The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior.CVE-2019-20045 · Other software · S3india · reported by MITREHigh 7.5

    The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5.0 and prior. Specially crafted malicious packets could cause disconnection of active authentic connections or reboot of device. This is a different issue than CVE-2019-16879 and CVE-2019-20046.

    Product
    Husky RTU 6049-e70 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.