Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
656 results · page 9 of 14
Jun 3, 2019The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows an authenticated, remote attacker with least privileges ('User Console Only' role) to potentiaCVE-2018-5404 · Other software · Quest Kace · reported by cret@cert.orgMedium 6.5
The Quest Kace K1000 Appliance, versions prior to 9.0.270, allows an authenticated, remote attacker with least privileges ('User Console Only' role) to potentially exploit multiple Blind SQL Injection vulnerabilities to retrieve sensitive information from the database or copy the entire database. An authenticated remote attacker could leverage Blind SQL injections to obtain sensitive data.
- Product
- K1000 Appliance
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.quest.comkb.cert.org
Apr 30, 2019The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmwareCVE-2019-3930 · Other software · Crestron · reported by vulnreport@tenable.comCritical 9.8
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
- Product
- Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteSh
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtenable.comtenable.com
Apr 9, 2019Advantech WebAccess 8.3.4 allows unauthenticated, remote attackers to delete arbitrary files via IOCTL 10005 RPC.CVE-2019-3941 · Other software · Advantech · reported by vulnreport@tenable.comHigh 7.5
Advantech WebAccess 8.3.4 allows unauthenticated, remote attackers to delete arbitrary files via IOCTL 10005 RPC.
- Product
- WebAccess
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comtenable.com
Apr 2, 2019An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.1316CVE-2019-6531 · Other software · Kunbus · reported by ics-cert@hq.dhs.govHigh 8.1
An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) if the attacker is in an MITM position.
- Product
- PR100088 Modbus gateway
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 2, 2019VMware Workstation (14.x before 14.1.6) and Fusion (10.x before 10.1.6) contain an out-of-bounds write vulnerability in the e1000 virtual network adapter.CVE-2019-5524 · Other software · VMware · reported by security@vmware.comHigh 8.8
VMware Workstation (14.x before 14.1.6) and Fusion (10.x before 10.1.6) contain an out-of-bounds write vulnerability in the e1000 virtual network adapter. This issue may allow a guest to execute code on the host.
- Product
- VMware Workstation, VMware Fusion
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comsecurityfocus.com
Mar 7, 2019A vulnerability in the network stack of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on theCVE-2019-1599 · Network & remote access · Cisco · reported by psirt@cisco.comHigh 8.6
A vulnerability in the network stack of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. The vulnerability is due to an issue with allocating and freeing memory buffers in the network stack. An attacker could exploit this vulnerability by sending crafted TCP streams to an affected device in a sustained way. A successful exploit could cause the network stack of an affected device to run out of available buffers, impairing operations of control plane and management plane protocols, resulting in a DoS condition. Note: This vulnerability can be triggered only by traffic that is destined to an affected device and cannot be exploited using traffic that transits an affected device. Nexus 1000V Switch for Microsoft Hyper-V is affected in versions prior to 5.2(1)SM3(2.1). Nexus 1000V Switch for VMware vSphere is affected in versions prior to 5.2(1)SV3(4.1a). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(6) and 9.2(2). Nexus 3500 Platform Switches are affected in versions prior to 6.0(2)A8(11), 7.0(3)I7(6), and 9.2(2). Nexus 3600 Platform Switches are affected in versions prior to
- Product
- Nexus 1000V Switch for Microsoft Hyper-V
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comtools.cisco.com
Mar 6, 2019A vulnerability in the 802.1X implementation for Cisco NX-OS Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condiCVE-2019-1594 · Network & remote access · Cisco · reported by psirt@cisco.comHigh 7.4
A vulnerability in the 802.1X implementation for Cisco NX-OS Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to incomplete input validation of Extensible Authentication Protocol over LAN (EAPOL) frames. An attacker could exploit this vulnerability by sending a crafted EAPOL frame to an interface on the targeted device. A successful exploit could allow the attacker to cause the Layer 2 (L2) forwarding process to restart multiple times, leading to a system-level restart of the device and a DoS condition. Note: This vulnerability affects only NX-OS devices configured with 802.1X functionality. Cisco Nexus 1000V Switch for VMware vSphere devices are affected in versions prior to 5.2(1)SV3(1.4b). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I7(4). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(4). Nexus 2000, 5500, 5600, and 6000 Series Switches are affected in versions prior to 7.3(5)N1(1) and 7.1(5)N1(1b). Nexus 7000 and 7700 Series Switches are affected in versions prior to 8.2(3). Nexus 9000 Series Fabric Switches in ACI Mode are affe
- Product
- Nexus 1000V Switch for VMware vSphere
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comtools.cisco.com
Feb 21, 2019A vulnerability in the TFTP service of Cisco Network Convergence System 1000 Series software could allow an unauthenticated, remote attacker to retrieve arbitraCVE-2019-1681 · Network & remote access · Cisco · reported by psirt@cisco.comHigh 7.5
A vulnerability in the TFTP service of Cisco Network Convergence System 1000 Series software could allow an unauthenticated, remote attacker to retrieve arbitrary files from the targeted device, possibly resulting in information disclosure. The vulnerability is due to improper validation of user-supplied input within TFTP requests processed by the affected software. An attacker could exploit this vulnerability by using directory traversal techniques in malicious requests sent to the TFTP service on a targeted device. An exploit could allow the attacker to retrieve arbitrary files from the targeted device, resulting in the disclosure of sensitive information. This vulnerability affects Cisco IOS XR Software releases prior to Release 6.5.2 for Cisco Network Convergence System 1000 Series devices when the TFTP service is enabled.
- Product
- Cisco Network Convergence System 1000 Series
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comtools.cisco.com
Feb 16, 2019An Insecure Direct Object Reference (IDOR) vulnerability exists in Zoho ManageEngine ServiceDesk Plus (SDP) before 10.0 build 10007 via an attachment to a requeCVE-2019-8395 · Email & office · Zohocorp · reported by MITRECritical 9.8
An Insecure Direct Object Reference (IDOR) vulnerability exists in Zoho ManageEngine ServiceDesk Plus (SDP) before 10.0 build 10007 via an attachment to a request.
- Product
- Manageengine Servicedesk Plus
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordmanageengine.commanageengine.com
Feb 12, 2019An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) CVE-2019-6549 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 7.2
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
- Product
- PR100088 Modbus gateway
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Feb 12, 2019Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to RelCVE-2019-6533 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govCritical 9.1
Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166).
- Product
- PR100088 Modbus gateway
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Feb 12, 2019PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user CVE-2019-6527 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govCritical 9.8
PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted.
- Product
- PR100088 Modbus gateway
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Jan 7, 2019Dokan, versions between 1.0.0.5000 and 1.2.0.1000, are vulnerable to a stack-based buffer overflow in the dokan1.sys driver.CVE-2018-5410 · Other software · Dokan · reported by cret@cert.orgHigh 7.8
Dokan, versions between 1.0.0.5000 and 1.2.0.1000, are vulnerable to a stack-based buffer overflow in the dokan1.sys driver. An attacker can create a device handle to the system driver and send arbitrary input that will trigger the vulnerability. This vulnerability was introduced in the 1.0.0.5000 version update.
- Product
- Open Source File System
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcwe.mitre.org
Dec 26, 2018An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000.CVE-2018-19616 · Other software · Rockwellautomation · reported by MITREHigh 8.1
An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element.
- Product
- Powermonitor 1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comsecurityfocus.com
Dec 26, 2018Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions.CVE-2018-19615 · Other software · Rockwellautomation · reported by MITREMedium 6.1
Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted userâs web browser to gain access to the affected device.
- Product
- Powermonitor 1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comsecurityfocus.com
Dec 6, 2018Persistent Cross-Site Scripting (XSS) in the advancedsetup_websiteblocking.html Website Blocking page of the Actiontec C1000A router with firmware through CAC00CVE-2018-19922 · Other software · Actiontec · reported by MITREMedium 6.1
Persistent Cross-Site Scripting (XSS) in the advancedsetup_websiteblocking.html Website Blocking page of the Actiontec C1000A router with firmware through CAC004-31.30L.95 allows a remote attacker to inject arbitrary HTML into the Website Blocking page by inserting arbitrary HTML into the 'TodUrlAdd' URL parameter in a /urlfilter.cmd POST request.
- Product
- C1000a Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Dec 3, 2018HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 'Filename'.CVE-2018-7116 · Other software · Hewlett Packard Enterprise · reported by security-alert@hpe.comHigh 7.5
HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 'Filename'. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions.
- Product
- HPE Intelligent Management Center (IMC)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecuritytracker.com
Dec 3, 2018HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote buffer overflow in dbman.exe opcode 10001 on Windows.CVE-2018-7115 · Other software · Hewlett Packard Enterprise · reported by security-alert@hpe.comMedium 5.3
HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote buffer overflow in dbman.exe opcode 10001 on Windows. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions.
- Product
- HPE Intelligent Management Center (IMC)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecuritytracker.com
Nov 15, 2018Untrusted search path vulnerability in Baidu Browser Version 43.23.1000.500 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspeCVE-2018-0692 · Other software · Baidu, Inc. · reported by vultures@jpcert.or.jpHigh 7.8
Untrusted search path vulnerability in Baidu Browser Version 43.23.1000.500 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory.
- Product
- Baidu Browser
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 29, 2018An XSS issue was discovered in index.php/admin/area/editarea/id/110000 in YUNUCMS 1.1.5.CVE-2018-18723 · Other software · Yunucms · reported by MITREMedium 4.8
An XSS issue was discovered in index.php/admin/area/editarea/id/110000 in YUNUCMS 1.1.5.
- Product
- Yunucms
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Sep 6, 2018thumbnail processing that can result in remote code execution due to an incomplete fix for CVE-2017-1000600: WordPress version 4.9.8 and earlier contains a CWE-20 Input ValidationCVE-2018-1000773 · WordPress plugins & themes · reported by MITREHigh 8.8
WordPress version 4.9.8 and earlier contains a CWE-20 Input Validation vulnerability in thumbnail processing that can result in remote code execution due to an incomplete fix for CVE-2017-1000600. This attack appears to be exploitable via thumbnail upload by an authenticated user and may require additional plugins in order to be exploited however this has not been confirmed at this time.
- Product
- thumbnail processing that can result in remote code execution due to an incomplete fix for CVE-2017-1000600
- Affected
- up to 4.9.8
- What to do
- Affects up to 4.9.8. Update thumbnail processing that can result in remote code execution due to an incomplete fix for CVE-2017-1000600 to the newest version and check its changelog mentions this fix; if there isn’t one yet, deactivate it until there is.
Full record and what to do →NVD recordsecurityfocus.comtheregister.co.uk
Aug 15, 2018VMware Workstation (14.x before 14.1.3) and Fusion (10.x before 10.1.3) contain an out-of-bounds write vulnerability in the e1000 device.CVE-2018-6973 · Other software · VMware · reported by security@vmware.comHigh 8.8
VMware Workstation (14.x before 14.1.3) and Fusion (10.x before 10.1.3) contain an out-of-bounds write vulnerability in the e1000 device. This issue may allow a guest to execute code on the host.
- Product
- Workstation
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecuritytracker.com
Jul 11, 2018QFX5200 and QFX10002 devices that have been shipped with Junos OS 15.1X53-D21, 15.1X53-D30, 15.1X53-D31, 15.1X53-D32, 15.1X53-D33 and 15.1X53-D60 or have been uCVE-2018-0035 · Network & remote access · Juniper Networks · reported by sirt@juniper.netMedium 4.4
QFX5200 and QFX10002 devices that have been shipped with Junos OS 15.1X53-D21, 15.1X53-D30, 15.1X53-D31, 15.1X53-D32, 15.1X53-D33 and 15.1X53-D60 or have been upgraded to these releases using the .bin or .iso images may contain an unintended additional Open Network Install Environment (ONIE) partition. This additional partition allows the superuser to reboot to the ONIE partition which will wipe out the content of the Junos partition and its configuration. Once rebooted, the ONIE partition will not have root password configured, thus any user can access the console or SSH, using an IP address acquired from DHCP, as root without password. Once the device has been shipped or upgraded with the ONIE partition installed, the issue will persist. Simply upgrading to higher release via the CLI will not resolve the issue. No other Juniper Networks products or platforms are affected by this issue.
- Product
- Junos OS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecuritytracker.comkb.juniper.net
Jul 9, 2018A Local File Inclusion (LFI) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the downloading of arbitrary files via an unCVE-2018-11543 · Other software · Ribboncommunications · reported by MITREHigh 7.5
A Local File Inclusion (LFI) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the downloading of arbitrary files via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140.
- Product
- Sonus SBC 1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordgist.github.comsupport.sonus.net
Jul 9, 2018A Remote Command Execution (RCE) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the execution of arbitrary commands via CVE-2018-11542 · Other software · Ribboncommunications · reported by MITRECritical 9.8
A Remote Command Execution (RCE) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the execution of arbitrary commands via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140.
- Product
- Sonus SBC 1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordgist.github.comsupport.sonus.net
Jul 9, 2018A root privilege escalation vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows unauthorised access to privileged content via an CVE-2018-11541 · Other software · Ribboncommunications · reported by MITRECritical 9.8
A root privilege escalation vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows unauthorised access to privileged content via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140.
- Product
- Sonus SBC 1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordgist.github.comsupport.sonus.net
Jun 17, 2018The _addguess function of a simplelottery smart contract implementation for 1000 Guess, an Ethereum gambling game, generates a random value with publicly readabCVE-2018-12454 · Other software · 1000guess · reported by MITREHigh 7.5
The _addguess function of a simplelottery smart contract implementation for 1000 Guess, an Ethereum gambling game, generates a random value with publicly readable variables such as the current block information and a private variable (which can be read with a getStorageAt call). Therefore, it allows attackers to always win and get rewards.
- Product
- 1000 Guess
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 24, 2018SimpliSafe Original has Unencrypted Keypad Transmissions, which allows physically proximate attackers to discover the PIN.CVE-2018-11402 · Other software · Simplisafe · reported by MITREMedium 6.6
SimpliSafe Original has Unencrypted Keypad Transmissions, which allows physically proximate attackers to discover the PIN.
- Product
- U9k-kp1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsimplisafe.comsimpleorsecure.net
May 24, 2018In SimpliSafe Original, RF Interference (e.g., an extremely strong 433.92 MHz signal) by a physically proximate attacker does not cause a notification.CVE-2018-11401 · Other software · Simplisafe · reported by MITREMedium 4.6
In SimpliSafe Original, RF Interference (e.g., an extremely strong 433.92 MHz signal) by a physically proximate attacker does not cause a notification.
- Product
- U9k-bs1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsimplisafe.comsimpleorsecure.net
May 24, 2018In SimpliSafe Original, the Base Station fails to detect tamper attempts: it does not send a notification if a physically proximate attacker removes the batteryCVE-2018-11400 · Other software · Simplisafe · reported by MITREMedium 4.6
In SimpliSafe Original, the Base Station fails to detect tamper attempts: it does not send a notification if a physically proximate attacker removes the battery and external power.
- Product
- U9k-bs1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsimplisafe.comsimpleorsecure.net
May 24, 2018SimpliSafe Original has Unencrypted Sensor Transmissions, which allows physically proximate attackers to obtain potentially sensitive information about the specCVE-2018-11399 · Other software · Simplisafe · reported by MITREMedium 4.3
SimpliSafe Original has Unencrypted Sensor Transmissions, which allows physically proximate attackers to obtain potentially sensitive information about the specific times when alarm-system events occur.
- Product
- U9k-es1000 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsimplisafe.comsimpleorsecure.net
Apr 17, 2018A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CVE-2018-8838 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govMedium 6.5
A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H).
- Product
- Yokogawa CENTUM and Exaopc
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 4, 2018Main_Analysis_Content.asp in /apply.cgi on ASUS RT-AC66U, RT-AC68U, RT-AC86U, RT-AC88U, RT-AC1900, RT-AC2900, and RT-AC3100 devices before 3.0.0.4.384_10007; RTCVE-2018-9285 · Network & remote access · Asus · reported by MITRECritical 9.8
Main_Analysis_Content.asp in /apply.cgi on ASUS RT-AC66U, RT-AC68U, RT-AC86U, RT-AC88U, RT-AC1900, RT-AC2900, and RT-AC3100 devices before 3.0.0.4.384_10007; RT-N18U devices before 3.0.0.4.382.39935; RT-AC87U and RT-AC3200 devices before 3.0.0.4.382.50010; and RT-AC5300 devices before 3.0.0.4.384.20287 allows OS command injection via the pingCNT and destIP fields of the SystemCmd variable.
- Product
- Rt-ac66u Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comfortiguard.com
Mar 20, 2018GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials.CVE-2017-14008 · Other software · GE Healthcare · reported by ics-cert@hq.dhs.govCritical 9.8
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
- Product
- GE Centricity PACS RA1000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 15, 2018Zoho ManageEngine EventLog Analyzer version 11.0 build 11000 has Stored XSS related to the index2.do?url=editAlertForm&tab=alert&alert=profile URI and the Edit CVE-2018-8721 · Email & office · Zohocorp · reported by MITREMedium 6.1
Zoho ManageEngine EventLog Analyzer version 11.0 build 11000 has Stored XSS related to the index2.do?url=editAlertForm&tab=alert&alert=profile URI and the Edit Alert Profile screen
- Product
- Manageengine Eventlog Analyzer
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.compitstop.manageengine.com
Mar 7, 2018GPAC through 0.7.1 has a Buffer Overflow in the gf_media_avc_read_sps function in media_tools/av_parsers.c, a different vulnerability than CVE-2018-1000100.CVE-2018-7752 · Other software · Gpac · reported by MITREHigh 7.8
GPAC through 0.7.1 has a Buffer Overflow in the gf_media_avc_read_sps function in media_tools/av_parsers.c, a different vulnerability than CVE-2018-1000100.
- Product
- Gpac
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Mar 6, 2018A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic PCVE-2018-5471 · Other software · Belden · reported by ics-cert@hq.dhs.govMedium 5.9
A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
- Product
- Hirschmann Rs20-0900mmm2tdau
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 6, 2018An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUCVE-2018-5469 · Other software · Belden · reported by ics-cert@hq.dhs.govCritical 9.8
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication.
- Product
- Hirschmann Rs20-0900mmm2tdau
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 6, 2018An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUCVE-2018-5467 · Other software · Belden · reported by ics-cert@hq.dhs.govMedium 6.5
An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An information exposure through query strings vulnerability in the web interface has been identified, which may allow an attacker to impersonate a legitimate user.
- Product
- Hirschmann Rs20-0900mmm2tdau
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 6, 2018A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches.CVE-2018-5465 · Other software · Belden · reported by ics-cert@hq.dhs.govHigh 8.8
A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.
- Product
- Hirschmann Rs20-0900mmm2tdau
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 6, 2018An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform SwitchesCVE-2018-5461 · Other software · Belden · reported by ics-cert@hq.dhs.govMedium 6.5
An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
- Product
- Hirschmann Rs20-0900mmm2tdau
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6633 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x80000038.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6632 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x80000110.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110009.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6631 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110009.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x80000170.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6630 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x8000014c.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6629 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x80000118.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6628 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x8000010c.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 5, 2018In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have CVE-2018-6626 · Other software · Micropoint · reported by MITREHigh 7.8
In Micropoint proactive defense software 2.0.20266.0146, the driver file (mp110005.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x80000035.
- Product
- Proactive Defense
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jan 25, 2018Biscom Secure File Transfer (SFT) 5.0.1000 through 5.0.1048 does not validate the dataFieldId value, and uses sequential numbers, which allows remote authenticaCVE-2016-10710 · Other software · Biscom · reported by MITREHigh 8.1
Biscom Secure File Transfer (SFT) 5.0.1000 through 5.0.1048 does not validate the dataFieldId value, and uses sequential numbers, which allows remote authenticated users to overwrite or read files via crafted requests. Version 5.0.1050 contains the fix.
- Product
- Secure File Transfer
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordthreat.tevora.comthreat.tevora.com
Jan 22, 2018An issue was discovered in AsusWRT before 3.0.0.4.384_10007.CVE-2018-6000 · Network & remote access · Asus · reported by MITRECritical 9.8
An issue was discovered in AsusWRT before 3.0.0.4.384_10007. The do_vpnupload_post function in router/httpd/web.c in vpnupload.cgi provides functionality for setting NVRAM configuration values, which allows attackers to set the admin password and launch an SSH daemon (or enable infosvr command mode), and consequently obtain remote administrative access, via a crafted request. This is available to unauthenticated attackers in conjunction with CVE-2018-5999.
- Product
- Asuswrt
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordblogs.securiteam.comgithub.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.