Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 8 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
457new WordPress flaws this week
390,525entries in the database

503 results · page 8 of 11

  • Aug 2, 2021A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software CVE-2021-37164 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. In the tcpTxThread function, the received data is copied to a stack buffer. An off-by-3 condition can occur, resulting in a stack-based buffer overflow.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2021An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software CVE-2021-37163 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    An insecure permissions issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus operated by released versions of software before Nexus Software 7.2.5.7. The device has two user accounts with passwords that are hardcoded.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2021A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software CVE-2021-37162 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2021A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of softwareCVE-2021-37161 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    A buffer overflow issue was discovered in the HMI3 Control Panel contained within the Swisslog Healthcare Nexus Panel, operated by released versions of software before Nexus Software 7.2.5.7. A buffer overflow allows an attacker to overwrite an internal queue data structure and can lead to remote code execution.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2021A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus SoftwCVE-2021-37160 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    A firmware validation issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. There is no firmware validation (e.g., cryptographic signature validation) during a File Upload for a firmware update.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2021A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software CVE-2021-37165 · Other software · Swisslog-healthcare · reported by MITRECritical 9.8

    A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. When a message is sent to the HMI TCP socket, it is forwarded to the hmiProcessMsg function through the pendingQ, and may lead to remote code execution.

    Product
    Hmi-3 Control Panel Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021Improper check vulnerability in Samsung Health prior to version 6.17 allows attacker to read internal cache data via exported component.CVE-2021-25425 · Computers, phones & browsers · Samsung Mobile · reported by mobile.security@samsung.comMedium 5.3

    Improper check vulnerability in Samsung Health prior to version 6.17 allows attacker to read internal cache data via exported component.

    Product
    Samsung Health
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021Intent redirection vulnerability in Samsung Health prior to version 6.16 allows attacker to execute privileged action.CVE-2021-25401 · Computers, phones & browsers · Samsung Mobile · reported by mobile.security@samsung.comHigh 7.8

    Intent redirection vulnerability in Samsung Health prior to version 6.16 allows attacker to execute privileged action.

    Product
    Samsung Health
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021The vSphere Client (HTML5) contains a vulnerability in a vSphere authentication mechanism for the Virtual SAN Health Check, Site Recovery, vSphere Lifecycle ManCVE-2021-21986 · Other software · VMware · reported by security@vmware.comCritical 9.8

    The vSphere Client (HTML5) contains a vulnerability in a vSphere authentication mechanism for the Virtual SAN Health Check, Site Recovery, vSphere Lifecycle Manager, and VMware Cloud Director Availability plug-ins. A malicious actor with network access to port 443 on vCenter Server may perform actions allowed by the impacted plug-ins without authentication.

    Product
    Vcenter Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 22, 2021Vulnerability in the PeopleSoft Enterprise PT PeopleTools product of Oracle PeopleSoft (component: Health Center).CVE-2021-2218 · Other software · Oracle Corporation · reported by secalert_us@oracle.comHigh 8.3

    Vulnerability in the PeopleSoft Enterprise PT PeopleTools product of Oracle PeopleSoft (component: Health Center). Supported versions that are affected are 8.56 and 8.57. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise PeopleSoft Enterprise PT PeopleTools. While the vulnerability is in PeopleSoft Enterprise PT PeopleTools, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of PeopleSoft Enterprise PT PeopleTools accessible data as well as unauthorized read access to a subset of PeopleSoft Enterprise PT PeopleTools accessible data and unauthorized ability to cause a partial denial of service (partial DOS) of PeopleSoft Enterprise PT PeopleTools. CVSS 3.1 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L).

    Product
    PeopleSoft Enterprise PT PeopleTools
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2021CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a setuid (and/or setgid) file.CVE-2021-28250 · Other software · CA · reported by MITREHigh 7.8

    CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a setuid (and/or setgid) file. When a component is run as an argument of the runpicEhealth executable, the script code will be executed as the ehealth user. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

    Product
    Ehealth Performance Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2021CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a Dynamically Linked Shared Object Library.CVE-2021-28249 · Other software · CA · reported by MITREHigh 8.8

    CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a Dynamically Linked Shared Object Library. To exploit the vulnerability, the ehealth user must create a malicious library in the writable RPATH, to be dynamically linked when the FtpCollector executable is run. The code in the library will be executed as the root user. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

    Product
    Ehealth Performance Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2021CA eHealth Performance Manager through 6.3.2.12 is affected by Improper Restriction of Excessive Authentication Attempts.CVE-2021-28248 · Other software · broadcom · reported by MITREHigh 7.5

    CA eHealth Performance Manager through 6.3.2.12 is affected by Improper Restriction of Excessive Authentication Attempts. An attacker is able to perform an arbitrary number of /web/frames/ authentication attempts using different passwords, and eventually gain access to a targeted account, NOTE: This vulnerability only affects products that are no longer supported by the maintainer

    Product
    ehealth
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2021CA eHealth Performance Manager through 6.3.2.12 is affected by Cross Site Scripting (XSS).CVE-2021-28247 · Other software · CA · reported by MITREMedium 5.4

    CA eHealth Performance Manager through 6.3.2.12 is affected by Cross Site Scripting (XSS). The impact is: An authenticated remote user is able to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and perform a Reflected Cross-Site Scripting attack against the platform users. The affected endpoints are: cgi/nhWeb with the parameter report, aviewbin/filtermibobjects.pl with the parameter namefilter, and aviewbin/query.pl with the parameters System, SystemText, Group, and GroupText. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

    Product
    Ehealth Performance Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2021CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a Dynamically Linked Shared Object Library.CVE-2021-28246 · Other software · broadcom · reported by MITREHigh 7.8

    CA eHealth Performance Manager through 6.3.2.12 is affected by Privilege Escalation via a Dynamically Linked Shared Object Library. A regular user must create a malicious library in the writable RPATH, to be dynamically linked when the emtgtctl2 executable is run. The code in the library will be executed as the ehealth user. NOTE: This vulnerability only affects products that are no longer supported by the maintainer

    Product
    ca_ehealth_performance_manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 20, 2021Vulnerability in the Oracle Argus Safety product of Oracle Health Sciences Applications (component: Letters).CVE-2021-2110 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 5

    Vulnerability in the Oracle Argus Safety product of Oracle Health Sciences Applications (component: Letters). The supported version that is affected is 8.2.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. While the vulnerability is in Oracle Argus Safety, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Oracle Argus Safety accessible data. CVSS 3.1 Base Score 5.0 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N).

    Product
    Argus Safety
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 20, 2021Vulnerability in the Oracle Argus Safety product of Oracle Health Sciences Applications (component: Case Form, Local Affiliate Form).CVE-2021-2040 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 6.1

    Vulnerability in the Oracle Argus Safety product of Oracle Health Sciences Applications (component: Case Form, Local Affiliate Form). The supported version that is affected is 8.2.2. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Oracle Argus Safety, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle Argus Safety accessible data as well as unauthorized read access to a subset of Oracle Argus Safety accessible data. CVSS 3.1 Base Score 6.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).

    Product
    Argus Safety
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 14, 2020GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.CVE-2020-25179 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 9.8

    GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.

    Product
    3.0t Signa Hdxt Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 14, 2020GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.CVE-2020-25175 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 9.8

    GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.

    Product
    3.0t Signa Hdxt Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 4, 2020A missing permission check in Jenkins Active Directory Plugin 2.19 and earlier allows attackers with Overall/Read permission to access the domain health check dCVE-2020-2302 · Websites & servers · Jenkins project · reported by jenkinsci-cert@googlegroups.comMedium 4.3

    A missing permission check in Jenkins Active Directory Plugin 2.19 and earlier allows attackers with Overall/Read permission to access the domain health check diagnostic page.

    Product
    Jenkins Active Directory Plugin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 16, 2020Jenkins Health Advisor by CloudBees Plugin 3.2.0 and earlier does not correctly perform a permission check in an HTTP endpoint, allowing attackers with Overall/CVE-2020-2258 · Websites & servers · Jenkins project · reported by jenkinsci-cert@googlegroups.comMedium 4.3

    Jenkins Health Advisor by CloudBees Plugin 3.2.0 and earlier does not correctly perform a permission check in an HTTP endpoint, allowing attackers with Overall/Read permission to view that HTTP endpoint.

    Product
    Jenkins Health Advisor by CloudBees Plugin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 9, 2020In the COVIDSafe application through 1.0.21 for Android, unsafe use of the Bluetooth transport option in the GATT connection allows attackers to trick the appliCVE-2020-14292 · Other software · Health · reported by MITREMedium 5.7

    In the COVIDSafe application through 1.0.21 for Android, unsafe use of the Bluetooth transport option in the GATT connection allows attackers to trick the application into establishing a connection over Bluetooth BR/EDR transport, which reveals the public Bluetooth address of the victim's phone without authorisation, bypassing the Bluetooth address randomisation protection in the user's phone.

    Product
    Covidsafe
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 1, 2020interface/new/new_comprehensive_save.php in LibreHealth EHR 2.0.0 suffers from an authenticated file upload vulnerability, allowing remote attackers to achieve CVE-2020-23829 · Other software · Librehealth · reported by MITREHigh 8.8

    interface/new/new_comprehensive_save.php in LibreHealth EHR 2.0.0 suffers from an authenticated file upload vulnerability, allowing remote attackers to achieve remote code execution (RCE) on the hosting webserver by uploading a maliciously crafted image.

    Product
    Librehealth EHR
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2020LibreHealth EMR v2.0.0 is affected by a Local File Inclusion issue allowing arbitrary PHP to be included and executed within the EMR application.CVE-2020-11439 · Other software · Librehealth · reported by MITREHigh 8.8

    LibreHealth EMR v2.0.0 is affected by a Local File Inclusion issue allowing arbitrary PHP to be included and executed within the EMR application.

    Product
    Librehealth EHR
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2020LibreHealth EMR v2.0.0 is affected by systemic CSRF.CVE-2020-11438 · Other software · Librehealth · reported by MITREHigh 8.8

    LibreHealth EMR v2.0.0 is affected by systemic CSRF.

    Product
    Librehealth EHR
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2020LibreHealth EMR v2.0.0 is affected by SQL injection allowing low-privilege authenticated users to enumerate the database.CVE-2020-11437 · Other software · Librehealth · reported by MITREMedium 4.3

    LibreHealth EMR v2.0.0 is affected by SQL injection allowing low-privilege authenticated users to enumerate the database.

    Product
    Librehealth EHR
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2020LibreHealth EMR v2.0.0 is vulnerable to XSS that results in the ability to force arbitrary actions on behalf of other users including administrators.CVE-2020-11436 · Other software · Librehealth · reported by MITRECritical 9

    LibreHealth EMR v2.0.0 is vulnerable to XSS that results in the ability to force arbitrary actions on behalf of other users including administrators.

    Product
    Librehealth EHR
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 9, 2020An elevation of privilege (user to user) vulnerability exists in Windows Security Health Service when handling certain objects in memory.To exploit the vulnerabCVE-2020-1324 · Computers, phones & browsers · Microsoft · reported by secure@microsoft.comHigh 7.8

    An elevation of privilege (user to user) vulnerability exists in Windows Security Health Service when handling certain objects in memory.To exploit the vulnerability, an attacker would first have to log on to the system, aka 'Windows Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2020-1162.

    Product
    Windows 10 Version 2004 for 32-bit Systems
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 9, 2020An elevation of privilege (user to user) vulnerability exists in Windows Security Health Service when handling certain objects in memory.To exploit the vulnerabCVE-2020-1162 · Computers, phones & browsers · Microsoft · reported by secure@microsoft.comHigh 7.8

    An elevation of privilege (user to user) vulnerability exists in Windows Security Health Service when handling certain objects in memory.To exploit the vulnerability, an attacker would first have to log on to the system, aka 'Windows Elevation of Privilege Vulnerability'. This CVE ID is unique from CVE-2020-1324.

    Product
    Windows
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 21, 2020Element OS prior to version 12.0 and Element HealthTools prior to version 2020.04.01.04 are susceptible to a vulnerability which when successfully exploited couCVE-2020-8572 · Other software · Netapp · reported by security-alert@netapp.comHigh 7.5

    Element OS prior to version 12.0 and Element HealthTools prior to version 2020.04.01.04 are susceptible to a vulnerability which when successfully exploited could lead to disclosure of sensitive information.

    Product
    Element Healthtools
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2020COVIDSafe through v1.0.17 allows a remote attacker to access phone name and model information because a BLE device can have four roles and COVIDSafe uses all ofCVE-2020-12860 · Other software · Health · reported by MITREMedium 5.3

    COVIDSafe through v1.0.17 allows a remote attacker to access phone name and model information because a BLE device can have four roles and COVIDSafe uses all of them. This allows for re-identification of a device, and potentially identification of the owner's name.

    Product
    Covidsafe
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2020Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext paCVE-2020-12859 · Other software · Health · reported by MITREMedium 5.3

    Unnecessary fields in the OpenTrace/BlueTrace protocol in COVIDSafe through v1.0.17 allow a remote attacker to identify a device model by observing cleartext payload data. This allows re-identification of devices, especially less common phone models or those in low-density situations.

    Product
    Covidsafe
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2020Non-reinitialisation of random data in the advertising payload in COVIDSafe v1.0.15 and v1.0.16 allows a remote attacker to re-identify Android devices running CVE-2020-12858 · Other software · Health · reported by MITREHigh 7.5

    Non-reinitialisation of random data in the advertising payload in COVIDSafe v1.0.15 and v1.0.16 allows a remote attacker to re-identify Android devices running COVIDSafe by scanning for their advertising beacons.

    Product
    Covidsafe
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2020Caching of GATT characteristic values (TempID) in COVIDSafe v1.0.15 and v1.0.16 allows a remote attacker to long-term re-identify an Android device running COVICVE-2020-12857 · Other software · Health · reported by MITREHigh 7.5

    Caching of GATT characteristic values (TempID) in COVIDSafe v1.0.15 and v1.0.16 allows a remote attacker to long-term re-identify an Android device running COVIDSafe.

    Product
    Covidsafe
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCVE-2020-6966 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 10

    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCVE-2020-6965 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 9.9

    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCVE-2020-6964 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govHigh 8.6

    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCVE-2020-6963 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 10

    In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CVE-2020-6962 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 10

    In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2020In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CVE-2020-6961 · Other software · Gehealthcare · reported by ics-cert@hq.dhs.govCritical 10

    In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.

    Product
    Apexpro Telemetry Server Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 15, 2020A missing permission check in Jenkins Health Advisor by CloudBees Plugin 3.0 and earlier allows attackers with Overall/Read permission to send a fixed email to CVE-2020-2094 · Websites & servers · Jenkins project · reported by jenkinsci-cert@googlegroups.comMedium 4.3

    A missing permission check in Jenkins Health Advisor by CloudBees Plugin 3.0 and earlier allows attackers with Overall/Read permission to send a fixed email to an attacker-specific recipient.

    Product
    Jenkins Health Advisor by CloudBees Plugin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 15, 2020A cross-site request forgery vulnerability in Jenkins Health Advisor by CloudBees Plugin 3.0 and earlier allows attackers to send an email with fixed content toCVE-2020-2093 · Websites & servers · Jenkins project · reported by jenkinsci-cert@googlegroups.comHigh 8.8

    A cross-site request forgery vulnerability in Jenkins Health Advisor by CloudBees Plugin 3.0 and earlier allows attackers to send an email with fixed content to an attacker-specified recipient.

    Product
    Jenkins Health Advisor by CloudBees Plugin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 18, 2019A memory leak in the mlx5_fw_fatal_reporter_dump() function in drivers/net/ethernet/mellanox/mlx5/core/health.c in the Linux kernel before 5.3.11 allows attackeCVE-2019-19047 · Computers, phones & browsers · Linux · reported by MITREMedium 5.5

    A memory leak in the mlx5_fw_fatal_reporter_dump() function in drivers/net/ethernet/mellanox/mlx5/core/health.c in the Linux kernel before 5.3.11 allows attackers to cause a denial of service (memory consumption) by triggering mlx5_crdump_collect() failures, aka CID-c7ed6d0183d5.

    Product
    Linux Kernel
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 28, 2019After installing the IBM Maximo Health- Safety and Environment Manager 7.6.1, a user is granted additional privileges that they are not normally allowed to acceCVE-2019-4546 · Other software · IBM · reported by psirt@us.ibm.comHigh 8.8

    After installing the IBM Maximo Health- Safety and Environment Manager 7.6.1, a user is granted additional privileges that they are not normally allowed to access. IBM X-Force ID: 165948.

    Product
    Maximo Health- Safety and Environment Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 28, 2019The debugging endpoint /debug/pprof is exposed over the unauthenticated Kubelet healthz port.CVE-2019-11248 · Other software · Kubernetes · reported by jordan@liggitt.netHigh 8.2

    The debugging endpoint /debug/pprof is exposed over the unauthenticated Kubelet healthz port. The go pprof endpoint is exposed over the Kubelet's healthz port. This debugging endpoint can potentially leak sensitive information such as internal Kubelet memory addresses and configuration, or for limited denial of service. Versions prior to 1.15.0, 1.14.4, 1.13.8, and 1.12.10 are affected. The issue is of medium severity, but not exposed by the default configuration.

    Product
    Kubernetes
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2019Observational Health Data Sciences and Informatics (OHDSI) WebAPI before 2.7.2 allows SQL injection in FeatureExtractionService.java.CVE-2019-15563 · Other software · Ohdsi · reported by MITRECritical 9.8

    Observational Health Data Sciences and Informatics (OHDSI) WebAPI before 2.7.2 allows SQL injection in FeatureExtractionService.java.

    Product
    Webapi
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 19, 2019SQL Injection exists in HealthNode Hospital Management System 1.0 via the id parameter to dashboard/Patient/info.php or dashboard/Patient/patientdetails.php.CVE-2018-17393 · Other software · Healthnode Hospital Management System Project · reported by MITRECritical 9.8

    SQL Injection exists in HealthNode Hospital Management System 1.0 via the id parameter to dashboard/Patient/info.php or dashboard/Patient/patientdetails.php.

    Product
    Healthnode Hospital Management System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 23, 2019Vulnerability in the Oracle Health Sciences Data Management Workbench component of Oracle Health Sciences Applications (subcomponent: User Interface).CVE-2019-2629 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 5.4

    Vulnerability in the Oracle Health Sciences Data Management Workbench component of Oracle Health Sciences Applications (subcomponent: User Interface). The supported version that is affected is 2.4.8. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Health Sciences Data Management Workbench. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle Health Sciences Data Management Workbench accessible data as well as unauthorized read access to a subset of Oracle Health Sciences Data Management Workbench accessible data. CVSS 3.0 Base Score 5.4 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N).

    Product
    Health Sciences Data Management Workbench
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2019The Pronestor PNHM (aka Health Monitoring or HealthMonitor) add-in before 8.1.13.0 for Outlook has "BUILTIN\Users:(I)(F)" permissions for the "%PROGRAMFILES(X86CVE-2018-19113 · Other software · Pronestor · reported by MITREHigh 7.3

    The Pronestor PNHM (aka Health Monitoring or HealthMonitor) add-in before 8.1.13.0 for Outlook has "BUILTIN\Users:(I)(F)" permissions for the "%PROGRAMFILES(X86)%\proNestor\Outlook add-in for Pronestor\PronestorHealthMonitor.exe" file, which allows local users to gain privileges via a Trojan horse PronestorHealthMonitor.exe file.

    Product
    Pronestor Health Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 16, 2019Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Login).CVE-2019-2432 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 4.9

    Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Login). Supported versions that are affected are 8.1 and 8.2. Difficult to exploit vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Argus Safety. While the vulnerability is in Oracle Argus Safety, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle Argus Safety accessible data as well as unauthorized read access to a subset of Oracle Argus Safety accessible data. CVSS 3.0 Base Score 4.9 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N).

    Product
    Argus Safety
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.