Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 6 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
479new WordPress flaws this week
390,525entries in the database

2,861 results · page 7 of 58

  • May 23, 2025A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18).CVE-2022-31812 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the integrity of incoming packets. This could allow an unauthenticated remote attacker to create a denial of service condition.

    Product
    SiPass integrated
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 23, 2025A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions).CVE-2022-31807 · Other software · Siemens · reported by productcert@siemens.comMedium 5.9

    A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

    Product
    Building X - Security Manager Edge Controller (ACC-AP)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution for some Intel(R) Processors may allow an authenticated useCVE-2024-28956 · Other software · Siemens · reported by secure@intel.comMedium 5.7

    Exposure of Sensitive Information in Shared Microarchitectural Structures during Transient Execution for some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.

    Product
    SIMATIC S7-1500 CPU 1518-4 PN/DP MFP
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed).CVE-2025-40583 · Other software · Siemens · reported by productcert@siemens.comMedium 6.7

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices do transmit sensitive information in cleartext. This could allow a privileged local attacker to retrieve this sensitive information.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed).CVE-2025-40582 · Other software · Siemens · reported by productcert@siemens.comHigh 8.5

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed).CVE-2025-40581 · Other software · Siemens · reported by productcert@siemens.comHigh 8.4

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V2.1 HF0 with SINEMA Remote Connect Edge Client installed). Affected devices are vulnerable to an authentication bypass. This could allow a non-privileged local attacker to bypass the authentication of the SINEMA Remote Connect Edge Client, and to read and modify the configuration parameters.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40580 · Other software · Siemens · reported by productcert@siemens.comMedium 5.4

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40579 · Other software · Siemens · reported by productcert@siemens.comMedium 5.4

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions).CVE-2025-40578 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions). Affected devices do not properly handle multiple incoming Profinet packets received in rapid succession. An unauthenticated remote attacker can exploit this flaw by sending multiple packets in a very short time frame, which leads to a crash of the dcpd process.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40577 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40576 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40575 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40574 · Other software · Siemens · reported by productcert@siemens.comHigh 8.5

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to interact with the backupmanager service.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40573 · Other software · Siemens · reported by productcert@siemens.comMedium 6.7

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to path traversal attacks. This could allow a privileged local attacker to restore backups that are outside the backup folder.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0).CVE-2025-40572 · Other software · Siemens · reported by productcert@siemens.comMedium 6.8

    A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to access sensitive information stored on the device.

    Product
    SCALANCE LPE9403
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Mendix OIDC SSO (Mendix 10.12 compatible) (All versions < V4.0.1), Mendix OIDC SSO (Mendix 9 compatible) (All versions < CVE-2025-40571 · Other software · Siemens · reported by productcert@siemens.comLow 2.1

    A vulnerability has been identified in Mendix OIDC SSO (Mendix 10.12 compatible) (All versions < V4.0.1), Mendix OIDC SSO (Mendix 9 compatible) (All versions < V3.3.1), Mendix OIDC SSO V4.2 (Mendix 10 compatible) (All versions < V4.2.1), Mendix OIDC SSO V4.3 (Mendix 10 compatible) (All versions). The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development.

    Product
    Mendix OIDC SSO (Mendix 10.12 compatible)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1).CVE-2025-40566 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.

    Product
    SIMATIC PCS neo V4.1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 5CVE-2025-40556 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation.

    Product
    BACnet ATEC 550-440
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions).CVE-2025-40555 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3

    A vulnerability has been identified in APOGEE PXC+TALON TC Series (BACnet) (All versions). Affected devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the targeted device, and potentially reduce the availability of BACnet network. A power cycle is required to restore the device's normal operation.

    Product
    APOGEE PXC+TALON TC Series (BACnet)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (AllCVE-2025-33025 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4

    A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

    Product
    RUGGEDCOM ROX MX5000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (AllCVE-2025-33024 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4

    A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

    Product
    RUGGEDCOM ROX MX5000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (AllCVE-2025-32469 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4

    A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.

    Product
    RUGGEDCOM ROX MX5000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), TCVE-2025-32454 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3

    A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.14), Teamcenter Visualization V2312 (All versions < V2312.0010), Teamcenter Visualization V2406 (All versions < V2406.0008), Teamcenter Visualization V2412 (All versions < V2412.0004), Tecnomatix Plant Simulation V2404 (All versions < V2404.0013). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.

    Product
    Teamcenter Visualization V14.3
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2ENCVE-2025-31930 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2

    Product
    IEC 1Ph 7.4kW Child socket
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) CVE-2025-31929 · Other software · Siemens · reported by productcert@siemens.comMedium 4.1

    A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter

    Product
    IEC 1Ph 7.4kW Child socket
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote CVE-2025-30176 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

    Product
    SIMATIC PCS neo V4.1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote CVE-2025-30175 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

    Product
    SIMATIC PCS neo V4.1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote CVE-2025-30174 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

    Product
    SIMATIC PCS neo V4.1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0).CVE-2025-26390 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3

    A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user.

    Product
    OZW672
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0).CVE-2025-26389 · Other software · Siemens · reported by productcert@siemens.comCritical 10

    A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.

    Product
    OZW672
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in MS/TP Point Pickup Module (All versions).CVE-2025-24510 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation.

    Product
    MS/TP Point Pickup Module
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions).CVE-2025-24009 · Other software · Siemens · reported by productcert@siemens.comHigh 8.2

    A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authentication to access critical resources. An attacker with network access could retrieve sensitive information from certain data records, including obfuscated safety passwords.

    Product
    SIRIUS 3RK3 Modular Safety System (MSS)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions).CVE-2025-24008 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.

    Product
    SIRIUS 3RK3 Modular Safety System (MSS)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions).CVE-2025-24007 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). Affected devices only provide weak password obfuscation. An attacker with network access could retrieve and de-obfuscate the safety password used for protection against inadvertent operating errors.

    Product
    SIRIUS 3RK3 Modular Safety System (MSS)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.2).CVE-2024-51447 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9

    A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.2). The login implementation of the affected application contains an observable response discrepancy vulnerability when validating usernames. This could allow an unauthenticated remote attacker to distinguish between valid and invalid usernames.

    Product
    Polarion V2310
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4).CVE-2024-51446 · Other software · Siemens · reported by productcert@siemens.comMedium 5.1

    A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The file upload feature of the affected application improperly sanitizes xml files. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by uploading specially crafted xml files that are later downloaded and viewed by other users of the application.

    Product
    Polarion V2310
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4).CVE-2024-51445 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The affected application contains a XML External Entity Injection (XXE) vulnerability in the docx import feature. This could allow an authenticated remote attacker to read arbitrary data from the application server.

    Product
    Polarion V2310
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4).CVE-2024-51444 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The application insufficiently validates user input for database read queries. This could allow an authenticated remote attacker to conduct an SQL injection attack that bypasses authorization controls and allows to download any data from the application's database.

    Product
    Polarion V2310
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 13, 2025A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highlyCVE-2024-23815 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)

    Product
    Desigo CC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 17, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-29931 · Other software · Siemens · reported by productcert@siemens.comMedium 6.3

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected product does not properly validate a length field in a serialized message which it uses to determine the amount of memory to be allocated for deserialization. This could allow an unauthenticated remote attacker to cause the application to allocate exhaustive amounts of memory and subsequently create a partial denial of service condition. Successful exploitation is only possible in redundant Telecontrol Server Basic setups and only if the connection between the redundant servers has been disrupted.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32872 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32871 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32870 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32869 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32868 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32867 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32866 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32865 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32864 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-32863 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

    Product
    TeleControl Server Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.