Dec 7, 2021An uncontrolled resource consumption vulnerability exists in Citrix ADC <13.0-83.27, <12.1-63.22 and 11.1-65.23 that could allow an attacker with access to NSIPCVE-2021-22956 · Network & remote access · Citrix · reported by support@hackerone.comHigh 7.5
An uncontrolled resource consumption vulnerability exists in Citrix ADC <13.0-83.27, <12.1-63.22 and 11.1-65.23 that could allow an attacker with access to NSIP or SNIP with management interface access to cause a temporary disruption of the Management GUI, Nitro API, and RPC communication.
- Product
- Application Delivery Controller Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.citrix.comsupport.citrix.com
Nov 12, 2021Belledonne Belle-sip before 5.0.20 can crash applications such as Linphone via " \ " in the display name of a From header.CVE-2021-43611 · Other software · Linphone · reported by MITREHigh 7.5
Belledonne Belle-sip before 5.0.20 can crash applications such as Linphone via " \ " in the display name of a From header.
- Product
- Belle-sip
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 12, 2021Belledonne Belle-sip before 5.0.20 can crash applications such as Linphone via an invalid From header (request URI without a parameter) in an unauthenticated SICVE-2021-43610 · Other software · Linphone · reported by MITREHigh 7.5
Belledonne Belle-sip before 5.0.20 can crash applications such as Linphone via an invalid From header (request URI without a parameter) in an unauthenticated SIP message, a different issue than CVE-2021-33056.
- Product
- Belle-sip
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 18, 2021An issue was discovered in function sofia_handle_sip_i_notify in sofia.c in SignalWire freeswitch before 1.10.6, may allow attackers to view sensitive informatiCVE-2021-36513 · Other software · Signalwire · reported by MITREHigh 7.5
An issue was discovered in function sofia_handle_sip_i_notify in sofia.c in SignalWire freeswitch before 1.10.6, may allow attackers to view sensitive information due to an uninitialized value.
- Product
- Freeswitch
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Sep 14, 2021A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versionsCVE-2021-37206 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Received webpackets are not properly processed. An unauthenticated remote attacker with access to any of the Ethernet interfaces could send specially crafted packets to force a restart of the target device.
- Product
- SIPROTEC 5 relays with CPU variants CP050
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Sep 14, 2021A vulnerability has been identified in SIMATIC CP 343-1 (incl.CVE-2021-33737 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3). Sending a specially crafted packet to port 102/tcp of an affected device could cause a denial of service condition. A restart is needed to restore normal operations.
- Product
- SIMATIC CP 343-1 (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Sep 14, 2021A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versionsCVE-2021-33720 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition.
- Product
- SIPROTEC 5 relays with CPU variants CP050
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Sep 14, 2021A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versionsCVE-2021-33719 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.
- Product
- SIPROTEC 5 relays with CPU variants CP050
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Sep 14, 2021A vulnerability has been identified in SIMATIC CP 1543-1 (incl.CVE-2021-33716 · Other software · Siemens · reported by productcert@siemens.comMedium 6.5
A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions < V3.0), SIMATIC CP 1545-1 (All versions < V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext.
- Product
- SIMATIC CP 1543-1 (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Aug 12, 2021Belledonne Belle-sip before 4.5.20, as used in Linphone and other products, can crash via an invalid From header in a SIP message.CVE-2021-33056 · Other software · Linphone · reported by MITREHigh 7.5
Belledonne Belle-sip before 4.5.20, as used in Linphone and other products, can crash via an invalid From header in a SIP message.
- Product
- Belle-sip
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 10, 2021A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl.CVE-2021-37172 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
- Product
- SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Jul 30, 2021An issue was discovered in PJSIP in Asterisk before 16.19.1 and before 18.5.1.CVE-2021-31878 · Other software · Digium · reported by MITREMedium 6.5
An issue was discovered in PJSIP in Asterisk before 16.19.1 and before 18.5.1. To exploit, a re-INVITE without SDP must be received after Asterisk has sent a BYE request.
- Product
- Asterisk
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownloads.asterisk.orgpacketstormsecurity.com
Jul 25, 2021Cross Site Scripting (XSS) exists in NCH Axon PBX v2.22 and earlier via the SipRule field (stored).CVE-2021-37457 · Other software · Nchsoftware · reported by MITREMedium 5.4
Cross Site Scripting (XSS) exists in NCH Axon PBX v2.22 and earlier via the SipRule field (stored).
- Product
- Axon PBX
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 23, 2021PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, CVE-2021-32686 · Other software · pjsip · reported by GitHubMedium 5.9
PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, and ICE. In PJSIP before version 2.11.1, there are a couple of issues found in the SSL socket. First, a race condition between callback and destroy, due to the accepted socket having no group lock. Second, the SSL socket parent/listener may get destroyed during handshake. Both issues were reported to happen intermittently in heavy load TLS connections. They cause a crash, resulting in a denial of service. These are fixed in version 2.11.1.
- Product
- pjproject
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 14, 2021In notifyProfileAdded and notifyProfileRemoved of SipService.java, there is a possible way to retrieve SIP account names due to a missing permission check.CVE-2021-0597 · Computers, phones & browsers · Google · reported by security@android.comMedium 5.5
In notifyProfileAdded and notifyProfileRemoved of SipService.java, there is a possible way to retrieve SIP account names due to a missing permission check. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-8.1 Android-9 Android-10 Android-11Android ID: A-176496502
- Product
- Android
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsource.android.comsource.android.com
Jun 21, 2021Cross Site Scripting (XSS) vulnerability in HisiPHP 2.0.8 via the group name in addgroup.html.CVE-2020-21130 · Other software · Hisiphp · reported by MITREMedium 6.1
Cross Site Scripting (XSS) vulnerability in HisiPHP 2.0.8 via the group name in addgroup.html.
- Product
- Hisiphp
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 12, 2021A NULL pointer dereference vulnerability exists in eXcall_api.c in Antisip eXosip2 through 5.2.0 when handling certain 3xx redirect responses.CVE-2021-32611 · Other software · Antisip · reported by MITREHigh 7.5
A NULL pointer dereference vulnerability exists in eXcall_api.c in Antisip eXosip2 through 5.2.0 when handling certain 3xx redirect responses.
- Product
- Exosip2
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordgit.savannah.nongnu.orggit.savannah.nongnu.org
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-27386 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could resul
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-27385 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which c
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-27384 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-27383 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-25662 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comus-cert.cisa.gov
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-25661 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comus-cert.cisa.gov
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl.CVE-2021-25660 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.
- Product
- SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced (incl.CVE-2020-25242 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions). Specially crafted packets sent to TCP port 102 could cause a Denial-of-Service condition on the affected devices. A cold restart might be necessary in order to recover.
- Product
- SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
May 12, 2021A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl.CVE-2019-19276 · Other software · Siemens · reported by productcert@siemens.comMedium 5.3
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
- Product
- SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Apr 29, 2021A vulnerability in the SIP inspection engine of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow aCVE-2021-1501 · Network & remote access · Cisco · reported by psirt@cisco.comHigh 8.6
A vulnerability in the SIP inspection engine of Cisco Adaptive Security Appliance (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a crash and reload of an affected device, resulting in a denial of service (DoS) condition.The vulnerability is due to a crash that occurs during a hash lookup for a SIP pinhole connection. An attacker could exploit this vulnerability by sending crafted SIP traffic through an affected device. A successful exploit could allow the attacker to cause a crash and reload of the affected device.
- Product
- Cisco Adaptive Security Appliance (ASA) Software
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtools.cisco.comtools.cisco.com
Apr 23, 2021Sipwise C5 NGCP www_csc version 3.6.4 up to and including platform NGCP CE mr3.8.13 allows call/click2dial CSRF attacks for actions with administrative privilegCVE-2021-31584 · Other software · Sipwise · reported by MITREHigh 8.8
Sipwise C5 NGCP www_csc version 3.6.4 up to and including platform NGCP CE mr3.8.13 allows call/click2dial CSRF attacks for actions with administrative privileges.
- Product
- Next Generation Communication Platform
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordlists.sipwise.compacketstormsecurity.com
Apr 23, 2021Sipwise C5 NGCP WWW Admin version 3.6.7 up to and including platform version NGCP CE 3.0 has multiple authenticated stored and reflected XSS vulnerabilities wheCVE-2021-31583 · Other software · Sipwise · reported by MITREMedium 5.4
Sipwise C5 NGCP WWW Admin version 3.6.7 up to and including platform version NGCP CE 3.0 has multiple authenticated stored and reflected XSS vulnerabilities when input passed via several parameters to several scripts is not properly sanitized before being returned to the user: Stored XSS in callforward/time/set/save (POST tsetname); Reflected XSS in addressbook (GET filter); Stored XSS in addressbook/save (POST firstname, lastname, company); and Reflected XSS in statistics/versions (GET lang).
- Product
- Next Generation Communication Platform
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordlists.sipwise.compacketstormsecurity.com
Mar 10, 2021PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, CVE-2021-21375 · Other software · pjsip · reported by GitHubMedium 6.5
PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, and ICE. In PJSIP version 2.10 and earlier, after an initial INVITE has been sent, when two 183 responses are received, with the first one causing negotiation failure, a crash will occur. This results in a denial of service.
- Product
- pjproject
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Mar 10, 2021PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, CVE-2020-15260 · Other software · pjsip · reported by GitHubMedium 6.8
PJSIP is a free and open source multimedia communication library written in C language implementing standard based protocols such as SIP, SDP, RTP, STUN, TURN, and ICE. In version 2.10 and earlier, PJSIP transport can be reused if they have the same IP address + port + protocol. However, this is insufficient for secure transport since it lacks remote hostname authentication. Suppose we have created a TLS connection to `sip.foo.com`, which has an IP address `100.1.1.1`. If we want to create a TLS connection to another hostname, say `sip.bar.com`, which has the same IP address, then it will reuse that existing connection, even though `100.1.1.1` does not have certificate to authenticate as `sip.bar.com`. The vulnerability allows for an insecure interaction without user awareness. It affects users who need access to connections to different destinations that translate to the same address, and allows man-in-the-middle attack if attacker can route a connection to another destination such as in the case of DNS spoofing.
- Product
- pjproject
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 18, 2021An issue was discovered in res_pjsip_session.c in Digium Asterisk through 13.38.1; 14.x, 15.x, and 16.x through 16.16.0; 17.x through 17.9.1; and 18.x through 1CVE-2021-26906 · Other software · Digium · reported by MITREMedium 5.9
An issue was discovered in res_pjsip_session.c in Digium Asterisk through 13.38.1; 14.x, 15.x, and 16.x through 16.16.0; 17.x through 17.9.1; and 18.x through 18.2.0, and Certified Asterisk through 16.8-cert5. An SDP negotiation vulnerability in PJSIP allows a remote server to potentially crash Asterisk by sending specific SIP responses that cause an SDP negotiation failure.
- Product
- Asterisk
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comseclists.org
Feb 18, 2021A buffer overflow in res_pjsip_diversion.c in Sangoma Asterisk versions 13.38.1, 16.15.1, 17.9.1, and 18.1.1 allows remote attacker to crash Asterisk by deliberCVE-2020-35776 · Other software · Digium · reported by MITREMedium 6.5
A buffer overflow in res_pjsip_diversion.c in Sangoma Asterisk versions 13.38.1, 16.15.1, 17.9.1, and 18.1.1 allows remote attacker to crash Asterisk by deliberately misusing SIP 181 responses.
- Product
- Asterisk
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comseclists.org
Feb 9, 2021A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl.CVE-2020-15798 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
- Product
- SIMATIC HMI Comfort Panels (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Jan 29, 2021An issue was discovered in res_pjsip_diversion.c in Sangoma Asterisk before 13.38.0, 14.x through 16.x before 16.15.0, 17.x before 17.9.0, and 18.x before 18.1.CVE-2020-35652 · Other software · Digium · reported by MITREMedium 6.5
An issue was discovered in res_pjsip_diversion.c in Sangoma Asterisk before 13.38.0, 14.x through 16.x before 16.15.0, 17.x before 17.9.0, and 18.x before 18.1.0. A crash can occur when a SIP message is received with a History-Info header that contains a tel-uri, or when a SIP 181 response is received that contains a tel-uri in the Diversion header.
- Product
- Asterisk
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownloads.asterisk.orgdownloads.asterisk.org
Jan 12, 2021A vulnerability has been identified in SCALANCE X-200 switch family (incl.CVE-2020-28391 · Other software · Siemens · reported by productcert@siemens.comMedium 5.9
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
- Product
- SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comus-cert.cisa.gov
Jan 12, 2021A vulnerability has been identified in SCALANCE X-200 switch family (incl.CVE-2020-25226 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
- Product
- SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Jan 12, 2021A vulnerability has been identified in SCALANCE X-200 switch family (incl.CVE-2020-15800 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
- Product
- SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Jan 12, 2021A vulnerability has been identified in SCALANCE X-200 switch family (incl.CVE-2020-15799 · Other software · Siemens · reported by productcert@siemens.comMedium 6.5
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
- Product
- SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 18, 2020The Bluetooth handset of Mitel MiVoice 6873i, 6930, and 6940 SIP phones with firmware before 5.1.0.SP6 could allow an unauthenticated attacker within Bluetooth CVE-2020-27639 · Email & office · Mitel · reported by MITREHigh 8.1
The Bluetooth handset of Mitel MiVoice 6873i, 6930, and 6940 SIP phones with firmware before 5.1.0.SP6 could allow an unauthenticated attacker within Bluetooth range to pair a rogue Bluetooth device when a phone handset loses connection, due to an improper pairing mechanism. A successful exploit could allow an attacker to eavesdrop on conversations.
- Product
- 6873i SIP Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25235 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The password used for authentication for the LOGO! Website and the LOGO! Access Tool is sent in a recoverable format. An attacker with access to the network traffic could derive valid logins.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25234 · Other software · Siemens · reported by productcert@siemens.comHigh 7.7
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions (UDF) in a password protected way. This protection is implemented in the software that displays the information. An attacker could reverse engineer the UDFs directly from stored program files.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25233 · Other software · Siemens · reported by productcert@siemens.comMedium 5.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25232 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25231 · Other software · Siemens · reported by productcert@siemens.comMedium 5.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25230 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Due to the usage of an outdated cipher mode on port 10005/tcp, an attacker could extract the encryption key from a captured communication with the device.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25229 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any affected device if using prepared messages that were generated for another device.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in LOGO! 8 BM (incl.CVE-2020-25228 · Other software · Siemens · reported by productcert@siemens.comCritical 9.8
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port.
- Product
- LOGO! 8 BM (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Dec 14, 2020A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl.CVE-2020-15796 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request.
- Product
- SIMATIC ET 200SP Open Controller (incl. SIPLUS variants)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Nov 18, 2020Kamailio before 5.4.0, as used in Sip Express Router (SER) in Sippy Softswitch 4.5 through 5.2 and other products, allows a bypass of a header-removal protectioCVE-2020-28361 · Other software · Kamailio · reported by MITREMedium 5.4
Kamailio before 5.4.0, as used in Sip Express Router (SER) in Sippy Softswitch 4.5 through 5.2 and other products, allows a bypass of a header-removal protection mechanism via whitespace characters. This occurs in the remove_hf function in the Kamailio textops module. Particular use of remove_hf in Sippy Softswitch may allow skilled attacker having a valid credential in the system to disrupt internal call start/duration accounting mechanisms leading potentially to a loss of revenue.
- Product
- Kamailio
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comsupport.sippysoft.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.