Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
331 results · page 6 of 7
Dec 21, 2017A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11.CVE-2017-16727 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.1
A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic.
- Product
- Nport W2150a Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Nov 23, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13701 · Other software · Moxa · reported by MITRECritical 9.8
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The backup file contains sensitive information in a insecure way. There is no salt for password hashing. Indeed passwords are stored without being ciphered with a timestamped ciphering method.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsentryo.net
Nov 23, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13699 · Other software · Moxa · reported by MITREHigh 7.5
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. The password encryption method can be retrieved from the firmware. This encryption method is based on a chall value that is sent in cleartext as a POST parameter. An attacker could reverse the password encryption algorithm to retrieve it.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsentryo.net
Nov 23, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13698 · Other software · Moxa · reported by MITREHigh 7.5
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. An attacker could extract public and private keys from the firmware image available on the MOXA website and could use them against a production switch that has the default keys embedded.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsentryo.netsentryo.net
Nov 17, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13703 · Other software · Moxa · reported by MITREHigh 7.5
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsentryo.netsentryo.net
Nov 17, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13702 · Other software · Moxa · reported by MITREMedium 5.3
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. Cookies can be stolen, manipulated, and reused.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsentryo.netsentryo.net
Nov 17, 2017An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices.CVE-2017-13700 · Other software · Moxa · reported by MITREMedium 4.8
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. There is XSS in the administration interface.
- Product
- Eds-g512e Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsentryo.netsentryo.net
Nov 16, 2017An Injection issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7CVE-2017-16719 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
An Injection issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to inject packets that could potentially disrupt the availability of the device.
- Product
- Nport 5110 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Nov 16, 2017An Information Exposure issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 CVE-2017-16715 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.6
An Information Exposure issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exploit a flaw in the handling of Ethernet frame padding that may allow for information exposure.
- Product
- Nport 5110 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Nov 16, 2017A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 VeCVE-2017-14028 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets.
- Product
- Nport 5110 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 29, 2017A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 BuiCVE-2017-7917 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.8
A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device.
- Product
- Oncell G3110-hspa Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
May 29, 2017An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCVE-2017-7915 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
- Product
- Oncell G3110-hspa Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
May 29, 2017A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.CVE-2017-7913 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
- Product
- Oncell G3110-hspa Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 20, 2017An exploitable OS Command Injection vulnerability exists in the web application 'ping' functionality of Moxa AWK-3131A Wireless Access Points running firmware 1CVE-2016-8721 · Other software · Moxa · reported by talos-cna@cisco.comCritical 9.1
An exploitable OS Command Injection vulnerability exists in the web application 'ping' functionality of Moxa AWK-3131A Wireless Access Points running firmware 1.1. Specially crafted web form input can cause an OS Command Injection resulting in complete compromise of the vulnerable device. An attacker can exploit this vulnerability remotely.
- Product
- Moxa AWK-3131A WAP
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 14, 2017XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure.CVE-2017-7457 · Other software · Moxa · reported by MITREMedium 5
XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure.
- Product
- Mx-aopc Server
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordhyp3rlinx.altervista.orgseclists.org
Apr 14, 2017Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials.CVE-2017-7456 · Other software · Moxa · reported by MITREHigh 7.5
Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials.
- Product
- Mxview
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordhyp3rlinx.altervista.orgseclists.org
Apr 14, 2017Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control.CVE-2017-7455 · Other software · Moxa · reported by MITREHigh 7.5
Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control.
- Product
- Mxview
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordhyp3rlinx.altervista.orgpacketstormsecurity.com
Apr 13, 2017An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point.CVE-2016-8727 · Other software · Moxa · reported by talos-cna@cisco.comHigh 7.5
An exploitable information disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point. Retrieving a series of URLs without authentication can reveal sensitive configuration and system information to an attacker.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename functionality of Moxa AWK-3131A Wireless AcCVE-2016-8726 · Other software · Moxa · reported by talos-cna@cisco.comHigh 7.5
An exploitable null pointer dereference vulnerability exists in the Web Application /forms/web_runScript iw_filename functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. An HTTP POST request with a blank line in the header will cause a segmentation fault in the web server.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable information disclosure vulnerability exists in the Web Application functionality of the Moxa AWK-3131A wireless access point running firmware 1.1CVE-2016-8725 · Other software · Moxa · reported by talos-cna@cisco.comMedium 5.3
An exploitable information disclosure vulnerability exists in the Web Application functionality of the Moxa AWK-3131A wireless access point running firmware 1.1. Retrieving a specific URL without authentication can reveal sensitive information to an attacker.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable information disclosure vulnerability exists in the serviceAgent functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1.CVE-2016-8724 · Other software · Moxa · reported by talos-cna@cisco.comMedium 5.3
An exploitable information disclosure vulnerability exists in the serviceAgent functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted TCP query will allow an attacker to retrieve potentially sensitive information.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable null pointer dereference exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1.CVE-2016-8723 · Other software · Moxa · reported by talos-cna@cisco.comHigh 7.5
An exploitable null pointer dereference exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Any HTTP GET request not preceded by an '/' will cause a segmentation fault in the web server. An attacker can send any of a multitude of potentially unexpected HTTP get requests to trigger this vulnerability.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable Information Disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless CVE-2016-8722 · Other software · Moxa · reported by talos-cna@cisco.comMedium 5.3
An exploitable Information Disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client. Retrieving a specific URL without authentication can reveal sensitive information to an attacker.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1.CVE-2016-8720 · Other software · Moxa · reported by talos-cna@cisco.comMedium 4.3
An exploitable HTTP Header Injection vulnerability exists in the Web Application functionality of the Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted HTTP request can inject a payload in the bkpath parameter which will be copied in to Location header of the HTTP response.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 13, 2017An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1.CVE-2016-8712 · Other software · Moxa · reported by talos-cna@cisco.comHigh 8.1
An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 12, 2017An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmwareCVE-2016-8719 · Other software · Moxa · reported by talos-cna@cisco.comMedium 6.1
An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 12, 2017An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1CVE-2016-8718 · Other software · Moxa · reported by talos-cna@cisco.comHigh 8.8
An exploitable Cross-Site Request Forgery vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted form can trick a client into making an unintentional request to the web server which will be treated as an authentic request.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Apr 12, 2017An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmCVE-2016-8716 · Other software · Moxa · reported by talos-cna@cisco.comHigh 7.5
An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials.
- Product
- AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtalosintelligence.comtalosintelligence.com
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9371 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 6.1
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. User-controlled input is not neutralized before being output to web page (CROSS-SITE SCRIPTING).
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9369 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Firmware can be updated over the network without authentication, which may allow remote code execution.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9367 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. The amount of resources requested by a malicious actor is not restricted, leading to a denial-of-service caused by resource exhaustion.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9366 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. An attacker can freely use brute force to determine parameters needed to bypass authentication.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9365 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.8
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Requests are not verified to be intentionally submitted by the proper user (CROSS-SITE REQUEST FORGERY).
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9363 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.3
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Buffer overflow vulnerability may allow an unauthenticated attacker to remotely execute arbitrary code.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9361 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Administration passwords can be retried without authenticating.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa DACenter Versions 1.4 and older.CVE-2016-9356 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.8
An issue was discovered in Moxa DACenter Versions 1.4 and older. The application may suffer from an unquoted search path issue.
- Product
- Dacenter
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa DACenter Versions 1.4 and older.CVE-2016-9354 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 5.5
An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption.
- Product
- Dacenter
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5CVE-2016-9348 · Other software · Moxa · reported by ics-cert@hq.dhs.govLow 3.3
An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext.
- Product
- Nport 5100 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1.CVE-2016-9346 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 5.3
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted.
- Product
- Miineport E1 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1.CVE-2016-9344 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files.
- Product
- Miineport E1 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa SoftCMS versions prior to Version 1.6.CVE-2016-9333 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION).
- Product
- Softcms
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa SoftCMS versions prior to Version 1.6.CVE-2016-9332 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.
- Product
- Softcms
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version CVE-2016-8379 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.1
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords.
- Product
- Iologik E1200 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version CVE-2016-8372 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.1
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.
- Product
- Iologik E1200 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 CVE-2016-8363 · Other software · Moxa · reported by ics-cert@hq.dhs.govCritical 10
An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. User is able to execute arbitrary OS commands on the server.
- Product
- Oncellg3470a-lte Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 CVE-2016-8362 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 6.5
An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. Any user is able to download log files by accessing a specific URL.
- Product
- Oncellg3470a-lte Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa SoftCMS versions prior to Version 1.6.CVE-2016-8360 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 8.1
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code.
- Product
- Softcms
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version CVE-2016-8359 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 6.1
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application fails to sanitize user input, which may allow an attacker to inject script or execute arbitrary code (CROSS-SITE SCRIPTING).
- Product
- Iologik E1200 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version CVE-2016-8350 · Other software · Moxa · reported by ics-cert@hq.dhs.govMedium 6.3
An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY).
- Product
- Iologik E1200 Series Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Moxa EDR-810 Industrial Secure Router.CVE-2016-8346 · Other software · Moxa · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Moxa EDR-810 Industrial Secure Router. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access configuration and log files (PRIVILEGE ESCALATION).
- Product
- Edr-810 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.