Feb 9, 2022In Preloader XFLASH, there is a possible escalation of privilege due to an improper certificate validation.CVE-2022-20034 · Computers, phones & browsers · MediaTek, Inc. · reported by security@mediatek.comMedium 6.8
In Preloader XFLASH, there is a possible escalation of privilege due to an improper certificate validation. This could lead to local escalation of privilege for an attacker who has physical access to the device with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06160806; Issue ID: ALPS06160806.
- Product
- MT6580, MT6735, MT6739, MT6761, MT6763, MT6765, MT6768, MT6769, MT6771, MT6779, MT6781, MT6785, MT6799, MT6833, MT6853, MT6873, MT6875, MT6877, MT6885, MT6891,
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcorp.mediatek.comcorp.mediatek.com
Nov 24, 2021The vSphere Web Client (FLEX/Flash) contains an SSRF (Server Side Request Forgery) vulnerability in the vSAN Web Client (vSAN UI) plug-in.CVE-2021-22049 · Other software · VMware · reported by security@vmware.comCritical 9.8
The vSphere Web Client (FLEX/Flash) contains an SSRF (Server Side Request Forgery) vulnerability in the vSAN Web Client (vSAN UI) plug-in. A malicious actor with network access to port 443 on vCenter Server may exploit this issue by accessing a URL request outside of vCenter Server or accessing an internal service.
- Product
- Vcenter Server
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 24, 2021The vSphere Web Client (FLEX/Flash) contains an unauthorized arbitrary file read vulnerability.CVE-2021-21980 · Other software · VMware · reported by security@vmware.comHigh 7.5
The vSphere Web Client (FLEX/Flash) contains an unauthorized arbitrary file read vulnerability. A malicious actor with network access to port 443 on vCenter Server may exploit this issue to gain access to sensitive information.
- Product
- Cloud Foundation
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 12, 2021A potential vulnerability in the SMI callback function used to access flash device in some ThinkPad models may allow an attacker with local access and elevated CVE-2021-3599 · Other software · Lenovo · reported by psirt@lenovo.comMedium 6.7
A potential vulnerability in the SMI callback function used to access flash device in some ThinkPad models may allow an attacker with local access and elevated privileges to execute arbitrary code.
- Product
- ThinkPad BIOS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.lenovo.comsupport.lenovo.com
Nov 8, 2021Qwizcards – online quizzes and flashcards: Does not properly sanitize and escape some of its settingsCVE-2021-24706 · WordPress plugins & themes · reported by WPScanMedium 4.8
The Qwizcards – online quizzes and flashcards WordPress plugin before 3.62 does not properly sanitize and escape some of its settings, allowing high privilege users to perform Cross-Site Scripting attacks even when the unfiltered_html capability is disallowed.
- Product
- Qwizcards – online quizzes and flashcards
- Fixed in
- 3.62
- What to do
- Update Qwizcards – online quizzes and flashcards to 3.62 or newer.
Oct 22, 2021FlashGet v1.9.6 was discovered to contain a buffer overflow in the 'current path directory' function.CVE-2020-28967 · Other software · Flashget · reported by MITREHigh 8.8
FlashGet v1.9.6 was discovered to contain a buffer overflow in the 'current path directory' function. This vulnerability allows attackers to elevate local process privileges via overwriting the registers.
- Product
- Flashget
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordvulnerability-lab.comvulnerability-lab.com
Oct 21, 2021IBM Flash System 900 could allow an authenticated attacker to obtain sensitive information and cause a denial of service due to a restricted shell escape vulnerCVE-2021-29873 · Other software · IBM · reported by psirt@us.ibm.comHigh 8.1
IBM Flash System 900 could allow an authenticated attacker to obtain sensitive information and cause a denial of service due to a restricted shell escape vulnerability. IBM X-Force ID: 206229.
- Product
- FlashSystem 900
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordexchange.xforce.ibmcloud.comibm.com
Oct 4, 2021The programmer installation utility does not perform a cryptographic authenticity or integrity checks of the software on the flash drive.CVE-2021-38396 · Other software · Boston Scientific · reported by ics-cert@hq.dhs.govMedium 6.5
The programmer installation utility does not perform a cryptographic authenticity or integrity checks of the software on the flash drive. An attacker could leverage this weakness to install unauthorized software using a specially crafted USB.
- Product
- ZOOM LATITUDE
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.cisa.govus-cert.cisa.gov
Sep 30, 2021ECOA BAS controller stores sensitive data (backup exports) in clear-text, thus the unauthenticated attacker can remotely query user password and obtain user’s pCVE-2021-41302 · Other software · ECOA · reported by twcert@cert.org.twHigh 7.3
ECOA BAS controller stores sensitive data (backup exports) in clear-text, thus the unauthenticated attacker can remotely query user password and obtain user’s privilege.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller is vulnerable to configuration disclosure when direct object reference is made to the specific files using an HTTP GET request.CVE-2021-41301 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller is vulnerable to configuration disclosure when direct object reference is made to the specific files using an HTTP GET request. This will enable the unauthenticated attacker to remotely disclose sensitive information and help her in authentication bypass, privilege escalation and full system access.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller’s special page displays user account and passwords in plain text, thus unauthenticated attackers can access the page and obtain privilege wiCVE-2021-41300 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller’s special page displays user account and passwords in plain text, thus unauthenticated attackers can access the page and obtain privilege with full functionality.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege withCVE-2021-41299 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege without logging in.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller is vulnerable to insecure direct object references that occur when the application provides direct access to objects based on user-supplied CVE-2021-41298 · Other software · ECOA · reported by twcert@cert.org.twHigh 8.8
ECOA BAS controller is vulnerable to insecure direct object references that occur when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability, attackers with general user's privilege can remotely bypass authorization and access the hidden resources in the system and execute privileged functionalities.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller is vulnerable to weak access control mechanism allowing authenticated user to remotely escalate privileges by disclosing credentials of admiCVE-2021-41297 · Other software · ECOA · reported by twcert@cert.org.twHigh 8.8
ECOA BAS controller is vulnerable to weak access control mechanism allowing authenticated user to remotely escalate privileges by disclosing credentials of administrative accounts in plain-text.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller uses weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the systeCVE-2021-41296 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller uses weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller has a Cross-Site Request Forgery vulnerability, thus authenticated attacker can remotely place a forged request at a malicious web page and CVE-2021-41295 · Other software · ECOA · reported by twcert@cert.org.twHigh 8.8
ECOA BAS controller has a Cross-Site Request Forgery vulnerability, thus authenticated attacker can remotely place a forged request at a malicious web page and execute CRUD commands (GET, POST, PUT, DELETE) to perform arbitrary operations in the system.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller suffers from a path traversal vulnerability, causing arbitrary files deletion.CVE-2021-41294 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.1
ECOA BAS controller suffers from a path traversal vulnerability, causing arbitrary files deletion. Using the specific GET parameter, unauthenticated attackers can remotely delete arbitrary files on the affected device and cause denial of service scenario.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller suffers from a path traversal vulnerability, causing arbitrary files disclosure.CVE-2021-41293 · Other software · ECOA · reported by twcert@cert.org.twHigh 7.5
ECOA BAS controller suffers from a path traversal vulnerability, causing arbitrary files disclosure. Using the specific POST parameter, unauthenticated attackers can remotely disclose arbitrary files on the affected device and disclose sensitive and system information.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller suffers from an authentication bypass vulnerability.CVE-2021-41292 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller suffers from an authentication bypass vulnerability. An unauthenticated attacker through cookie poisoning can remotely bypass authentication and disclose sensitive information and circumvent physical access controls in smart homes and buildings and manipulate HVAC.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller suffers from a path traversal content disclosure vulnerability.CVE-2021-41291 · Other software · ECOA · reported by twcert@cert.org.twHigh 7.5
ECOA BAS controller suffers from a path traversal content disclosure vulnerability. Using the GET parameter in File Manager, unauthenticated attackers can remotely disclose directory content on the affected device.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 30, 2021ECOA BAS controller suffers from an arbitrary file write and path traversal vulnerability.CVE-2021-41290 · Other software · ECOA · reported by twcert@cert.org.twCritical 9.8
ECOA BAS controller suffers from an arbitrary file write and path traversal vulnerability. Using the POST parameters, unauthenticated attackers can remotely set arbitrary values for location and content type and gain the possibility to execute arbitrary code on the affected device.
- Product
- ECS Router Controller ECS (FLASH)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtwcert.org.twtwcert.org.tw
Sep 8, 2021Buffer over read could occur due to incorrect check of buffer size while flashing emmc devices in Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon ICVE-2021-1928 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comMedium 4.6
Buffer over read could occur due to incorrect check of buffer size while flashing emmc devices in Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables, Snapdragon Wired Infrastructure and Networking
- Product
- Snapdragon Connectivity, Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables, Snapdragon Wired
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordqualcomm.comqualcomm.com
Jul 13, 2021Possible buffer over-read due to lack of length check while flashing meta images in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, SnapdCVE-2021-1901 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comMedium 4.6
Possible buffer over-read due to lack of length check while flashing meta images in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables
- Product
- Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Voice & Music, Snapdragon Wearables
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordqualcomm.comqualcomm.com
Jul 13, 2021Possible buffer over read due to lack of length check while flashing meta images in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, SnapdCVE-2021-1899 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comMedium 4.6
Possible buffer over read due to lack of length check while flashing meta images in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Wearables
- Product
- Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Mobile, Snapdragon Wearables
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordqualcomm.comqualcomm.com
May 21, 2021The flash read-out protection (RDP) level is not enforced during the device initialization phase of the SoloKeys Solo 4.0.0 & Somu and the Nitrokey FIDO2 token.CVE-2020-27208 · Other software · Solokeys · reported by MITREMedium 6.8
The flash read-out protection (RDP) level is not enforced during the device initialization phase of the SoloKeys Solo 4.0.0 & Somu and the Nitrokey FIDO2 token. This allows an adversary to downgrade the RDP level and access secrets such as private ECC keys from SRAM via the debug interface.
- Product
- Solo Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordeprint.iacr.orggithub.com
May 7, 2021Possible integer overflow due to improper length check while flashing an image in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Voice & MusicCVE-2021-1895 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comMedium 6.8
Possible integer overflow due to improper length check while flashing an image in Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Voice & Music
- Product
- Snapdragon Consumer IOT, Snapdragon Industrial IOT, Snapdragon Voice & Music
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordqualcomm.comqualcomm.com
May 4, 2021The IBM FlashSystem 900 user management GUI is vulnerable to stored cross-site scripting in code versions 1.5.2.8 and prior and 1.6.1.2 and prior.CVE-2020-4987 · Other software · IBM · reported by psirt@us.ibm.comMedium 5.4
The IBM FlashSystem 900 user management GUI is vulnerable to stored cross-site scripting in code versions 1.5.2.8 and prior and 1.6.1.2 and prior. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
- Product
- FlashSystem 900
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordexchange.xforce.ibmcloud.comibm.com
Mar 15, 2021When booting a Zync-7000 SOC device from nand flash memory, the nand driver in the ROM does not validate the inputs when reading in any parameters in the nand’sCVE-2021-27208 · Other software · Xilinx · reported by MITREMedium 6.8
When booting a Zync-7000 SOC device from nand flash memory, the nand driver in the ROM does not validate the inputs when reading in any parameters in the nand’s parameter page. IF a field read in from the parameter page is too large, this causes a buffer overflow that could lead to arbitrary code execution. Physical access and modification of the board assembly on which the Zynq-7000 SoC device mounted is needed to replace the original NAND flash memory with a NAND flash emulation device for this attack to be successful.
- Product
- Zynq-7000s Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Feb 8, 2021The Baseboard Management Controller (BMC) firmware in HPE Apollo 70 System prior to version 3.0.14.0 has a local buffer overflow in libifc.so webstartflash funcCVE-2021-25142 · Other software · HPE · reported by security-alert@hpe.comHigh 7.8
The Baseboard Management Controller (BMC) firmware in HPE Apollo 70 System prior to version 3.0.14.0 has a local buffer overflow in libifc.so webstartflash function.
- Product
- Baseboard Management Controller
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.hpe.comsupport.hpe.com
Nov 12, 2020A potential vulnerability in a dynamically loaded AMD driver in AMD VBIOS Flash Tool SDK may allow any authenticated user to escalate privileges to NT authorityCVE-2020-12927 · Other software · AMD · reported by psirt@amd.comHigh 7.8
A potential vulnerability in a dynamically loaded AMD driver in AMD VBIOS Flash Tool SDK may allow any authenticated user to escalate privileges to NT authority system.
- Product
- Vbios Flash Tool Software Development KIT
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 19, 2020A faultflasheventselectfact expression language injectionremote code execution vulnerability was discovered in HPE Intelligent Management Center (iMC) version(sCVE-2020-7189 · Other software · HP · reported by security-alert@hpe.comHigh 8.8
A faultflasheventselectfact expression language injectionremote code execution vulnerability was discovered in HPE Intelligent Management Center (iMC) version(s): Prior to iMC PLAT 7.3 (E0705P07).
- Product
- Intelligent Management Center
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.hpe.comsupport.hpe.com
Oct 14, 2020Adobe Flash Player version 32.0.0.433 (and earlier) are affected by an exploitable NULL pointer dereference vulnerability that could result in a crash and arbitCVE-2020-9746 · Other software · Adobe · reported by AdobeHigh 7
Adobe Flash Player version 32.0.0.433 (and earlier) are affected by an exploitable NULL pointer dereference vulnerability that could result in a crash and arbitrary code execution. Exploitation of this issue requires an attacker to insert malicious strings in an HTTP response that is by default delivered over TLS/SSL.
- Product
- Flash Player
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordhelpx.adobe.comhelpx.adobe.com
Sep 24, 2020A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: fCVE-2020-3477 · Network & remote access · Cisco · reported by psirt@cisco.comMedium 5.5
A vulnerability in the CLI parser of Cisco IOS Software and Cisco IOS XE Software could allow an authenticated, local attacker to access files from the flash: filesystem. The vulnerability is due to insufficient application of restrictions during the execution of a specific command. An attacker could exploit this vulnerability by using a specific command at the command line. A successful exploit could allow the attacker to obtain read-only access to files that are located on the flash: filesystem that otherwise might not have been accessible.
- Product
- Cisco IOS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtools.cisco.comtools.cisco.com
Sep 1, 2020In Lenovo systems, SMM BIOS Write Protection is used to prevent writes to SPI Flash.CVE-2020-8341 · Other software · Lenovo · reported by psirt@lenovo.comLow 2.4
In Lenovo systems, SMM BIOS Write Protection is used to prevent writes to SPI Flash. While this provides sufficient protection, an additional layer of protection is provided by SPI Protected Range Registers (PRx). After resuming from S3 sleep mode in various versions of BIOS for some Lenovo ThinkPad systems, the PRx is not set. This does not impact the SMM BIOS Write Protection, which keeps systems protected.
- Product
- ThinkPad
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.lenovo.comsupport.lenovo.com
Aug 31, 2020The flash memory readout protection in Gigadevice GD32F103 devices allows physical attackers to extract firmware via the debug interface by utilizing the DMA moCVE-2020-13472 · Other software · Gigadevice · reported by MITREMedium 4.6
The flash memory readout protection in Gigadevice GD32F103 devices allows physical attackers to extract firmware via the debug interface by utilizing the DMA module.
- Product
- Gd32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020Apex Microelectronics APM32F103 devices allow physical attackers to execute arbitrary code via a power glitch and a specific flash patch/breakpoint unit configuCVE-2020-13471 · Other software · Apexmic · reported by MITREMedium 6.8
Apex Microelectronics APM32F103 devices allow physical attackers to execute arbitrary code via a power glitch and a specific flash patch/breakpoint unit configuration.
- Product
- Apm32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020The flash memory readout protection in Gigadevice GD32VF103 devices allows physical attackers to extract firmware via the debug interface by utilizing the CPU.CVE-2020-13469 · Other software · Gigadevice · reported by MITREMedium 4.6
The flash memory readout protection in Gigadevice GD32VF103 devices allows physical attackers to extract firmware via the debug interface by utilizing the CPU.
- Product
- Gd32vf103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020The flash memory readout protection in China Key Systems & Integrated Circuit CKS32F103 devices allows physical attackers to extract firmware via the debug inteCVE-2020-13467 · Other software · Cksic · reported by MITREMedium 4.6
The flash memory readout protection in China Key Systems & Integrated Circuit CKS32F103 devices allows physical attackers to extract firmware via the debug interface and exception handling.
- Product
- Cks32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020STMicroelectronics STM32F103 devices through 2020-05-20 allow physical attackers to execute arbitrary code via a power glitch and a specific flash patch/breakpoCVE-2020-13466 · Other software · ST · reported by MITREMedium 6.8
STMicroelectronics STM32F103 devices through 2020-05-20 allow physical attackers to execute arbitrary code via a power glitch and a specific flash patch/breakpoint unit configuration.
- Product
- Stm32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020The flash memory readout protection in China Key Systems & Integrated Circuit CKS32F103 devices allows physical attackers to extract firmware via the debug inteCVE-2020-13464 · Other software · Cksic · reported by MITREMedium 4.2
The flash memory readout protection in China Key Systems & Integrated Circuit CKS32F103 devices allows physical attackers to extract firmware via the debug interface by utilizing the CPU or DMA module.
- Product
- Cks32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2020The flash memory readout protection in Apex Microelectronics APM32F103 devices allows physical attackers to extract firmware via the debug interface and exceptiCVE-2020-13463 · Other software · Apexmic · reported by MITREMedium 4.6
The flash memory readout protection in Apex Microelectronics APM32F103 devices allows physical attackers to extract firmware via the debug interface and exception handling.
- Product
- Apm32f103 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 22, 2020Incorrect access control in the firmware of Synaptics VFS75xx family fingerprint sensors that include external flash (all versions prior to 2019-11-15) allows aCVE-2019-18618 · Other software · Synaptics · reported by MITREMedium 6
Incorrect access control in the firmware of Synaptics VFS75xx family fingerprint sensors that include external flash (all versions prior to 2019-11-15) allows a local administrator or physical attacker to compromise the confidentiality of sensor data via injection of an unverified partition table.
- Product
- Vfs75xx Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.hp.comsupport.lenovo.com
Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12005 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
- Product
- Factorytalk Linx
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.govus-cert.gov
Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12003 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
- Product
- Factorytalk Linx
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.govus-cert.gov
Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12001 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govCritical 9.8
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.
- Product
- Factorytalk Linx
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.govzerodayinitiative.com
Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-11999 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.1
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.
- Product
- Factorytalk Linx
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.govus-cert.gov
Jun 12, 2020Adobe Flash Player Desktop Runtime 32.0.0.371 and earlier, Adobe Flash Player for Google Chrome 32.0.0.371 and earlier, and Adobe Flash Player for Microsoft EdgCVE-2020-9633 · Other software · Adobe · reported by AdobeCritical 9.8
Adobe Flash Player Desktop Runtime 32.0.0.371 and earlier, Adobe Flash Player for Google Chrome 32.0.0.371 and earlier, and Adobe Flash Player for Microsoft Edge and Internet Explorer 32.0.0.330 and earlier have an use after free vulnerability. Successful exploitation could lead to arbitrary code execution.
- Product
- Adobe Flash Player
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordhelpx.adobe.comsecurity.gentoo.org
Jun 9, 2020Lenovo implemented Intel CSME Anti-rollback ARB protections on some ThinkPad models to prevent roll back of CSME Firmware in flash.CVE-2020-8336 · Other software · Lenovo · reported by psirt@lenovo.comMedium 6.4
Lenovo implemented Intel CSME Anti-rollback ARB protections on some ThinkPad models to prevent roll back of CSME Firmware in flash.
- Product
- BIOS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.lenovo.comsupport.lenovo.com
Jun 2, 2020In Joomla! before 3.9.19, lack of input validation in the heading tag option of the "Articles - Newsflash" and "Articles - Categories" modules allows XSS.CVE-2020-13761 · Websites & servers · Joomla · reported by MITREMedium 6.1
In Joomla! before 3.9.19, lack of input validation in the heading tag option of the "Articles - Newsflash" and "Articles - Categories" modules allows XSS.
- Product
- Joomla!
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddeveloper.joomla.orgdeveloper.joomla.org
May 19, 2020Whale Browser Installer before 1.2.0.5 versions don't support signature verification for Flash installer.CVE-2020-9753 · Other software · NAVER Corporation · reported by cve@navercorp.comCritical 9.1
Whale Browser Installer before 1.2.0.5 versions don't support signature verification for Flash installer.
- Product
- Whale Browser Installer
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcve.naver.comcve.naver.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.