Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 56 min ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
36added in the last 30 days
585new WordPress flaws this week
391,310entries in the database

1,743 results · page 30 of 35

  • Sep 7, 2017A vulnerability in the ROM Monitor (ROMMON) code of Cisco IR800 Integrated Services Router Software could allow an unauthenticated, local attacker to boot an unCVE-2017-12223 · Network & remote access · Cisco · reported by psirt@cisco.comMedium 6.4

    A vulnerability in the ROM Monitor (ROMMON) code of Cisco IR800 Integrated Services Router Software could allow an unauthenticated, local attacker to boot an unsigned Hypervisor on an affected device and compromise the integrity of the system. The vulnerability is due to insufficient sanitization of user input. An attacker who can access an affected router via the console could exploit this vulnerability by entering ROMMON mode and modifying ROMMON variables. A successful exploit could allow the attacker to execute arbitrary code and install a malicious version of Hypervisor firmware on an affected device. Cisco Bug IDs: CSCvb44027.

    Product
    Ir800 Integrated Services Router Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 29, 2017Buffer overflow in the Group messages monitor (Falcon) in KNX ETS 4.1.5 (Build 3246) allows remote attackers to execute arbitrary code via a crafted KNXnet/IP UCVE-2015-8299 · Other software · KNX · reported by MITRECritical 9.8

    Buffer overflow in the Group messages monitor (Falcon) in KNX ETS 4.1.5 (Build 3246) allows remote attackers to execute arbitrary code via a crafted KNXnet/IP UDP packet.

    Product
    ETS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 24, 2017Cross-site scripting (XSS-STORED) vulnerability in the DEVICES OR SENSORS functionality in Paessler PRTG Network Monitor before 17.3.33.2654 allows authenticateCVE-2017-12879 · Other software · Paessler · reported by MITREMedium 5.4

    Cross-site scripting (XSS-STORED) vulnerability in the DEVICES OR SENSORS functionality in Paessler PRTG Network Monitor before 17.3.33.2654 allows authenticated remote attackers to inject arbitrary web script or HTML.

    Product
    Prtg Network Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 21, 2017An Authentication Bypass (CWE-287) vulnerability in ESMAC (aka Enterprise Server Monitor and Control) in Micro Focus Enterprise Developer and Enterprise Server CVE-2017-7420 · Other software · Micro Focus · reported by security@opentext.comCritical 9.8

    An Authentication Bypass (CWE-287) vulnerability in ESMAC (aka Enterprise Server Monitor and Control) in Micro Focus Enterprise Developer and Enterprise Server 2.3 and earlier, 2.3 Update 1 before Hotfix 8, and 2.3 Update 2 before Hotfix 9 allows remote unauthenticated attackers to view and alter configuration information and alter the state of the running product (CWE-275).

    Product
    Micro Focus Enterprise Developer, Micro Focus Enterprise Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 18, 2017Cross-site scripting (XSS) vulnerability in Paessler PRTG Network Monitor before 17.2.32.2279 allows remote attackers to inject arbitrary web script or HTML viaCVE-2017-9816 · Other software · Paessler · reported by MITREMedium 6.1

    Cross-site scripting (XSS) vulnerability in Paessler PRTG Network Monitor before 17.2.32.2279 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

    Product
    Prtg Network Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 14, 2017An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0.CVE-2017-9662 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govMedium 5.3

    An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges.

    Product
    Monitouch V-sft
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 14, 2017A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0.CVE-2017-9660 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 8.8

    A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. A heap-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.

    Product
    Monitouch V-sft
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 14, 2017A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0.CVE-2017-9659 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 8.8

    A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.

    Product
    Monitouch V-sft
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 8, 2017Vulnerability in the Application Management Pack for Oracle E-Business Suite component of Oracle E-Business Suite (subcomponent: User Monitoring).CVE-2017-10179 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 6.5

    Vulnerability in the Application Management Pack for Oracle E-Business Suite component of Oracle E-Business Suite (subcomponent: User Monitoring). Supported versions that are affected are AMP 12.1.0.4.0 and AMP 13.1.1.1.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Application Management Pack for Oracle E-Business Suite. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Application Management Pack for Oracle E-Business Suite accessible data as well as unauthorized read access to a subset of Application Management Pack for Oracle E-Business Suite accessible data. CVSS 3.0 Base Score 6.5 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).

    Product
    Application Management Pack for Oracle E-Business Suite
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 3, 2017Zoho ManageEngine OpManager 11 through 12.2 uses a custom encryption algorithm to protect the credential used to access the monitored devices.CVE-2015-9107 · Email & office · Zohocorp · reported by MITRECritical 9.8

    Zoho ManageEngine OpManager 11 through 12.2 uses a custom encryption algorithm to protect the credential used to access the monitored devices. The implemented algorithm doesn't use a per-system key or even a salt; therefore, it's possible to create a universal decryptor.

    Product
    Manageengine Opmanager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 20, 2017IDERA Uptime Monitor 7.8 has SQL injection in /gadgets/definitions/uptime.CapacityWhatIfGadget/getmetrics.php via the element parameter.CVE-2017-11471 · Other software · Idera · reported by MITRECritical 9.8

    IDERA Uptime Monitor 7.8 has SQL injection in /gadgets/definitions/uptime.CapacityWhatIfGadget/getmetrics.php via the element parameter.

    Product
    Uptime Infrastructure Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 20, 2017IDERA Uptime Monitor 7.8 has SQL injection in /gadgets/definitions/uptime.CapacityWhatifGadget/getxenmetrics.php via the element parameter.CVE-2017-11470 · Other software · Idera · reported by MITRECritical 9.8

    IDERA Uptime Monitor 7.8 has SQL injection in /gadgets/definitions/uptime.CapacityWhatifGadget/getxenmetrics.php via the element parameter.

    Product
    Uptime Infrastructure Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 20, 2017get2post.php in IDERA Uptime Monitor 7.8 has directory traversal in the file_name parameter.CVE-2017-11469 · Other software · Idera · reported by MITREHigh 7.5

    get2post.php in IDERA Uptime Monitor 7.8 has directory traversal in the file_name parameter.

    Product
    Uptime Infrastructure Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2017IBM Tivoli Monitoring Portal v6 could allow a local (network adjacent) attacker to modify SQL commands to the Portal Server, when default client-server communicCVE-2017-1183 · Other software · IBM · reported by psirt@us.ibm.comHigh 7.5

    IBM Tivoli Monitoring Portal v6 could allow a local (network adjacent) attacker to modify SQL commands to the Portal Server, when default client-server communications, HTTP, are being used. IBM X-Force ID: 123494.

    Product
    Tivoli Monitoring V6
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2017IBM Tivoli Monitoring Portal v6 could allow a local (network adjacent) attacker to execute arbitrary commands on the system, when default client-server default CVE-2017-1182 · Other software · IBM · reported by psirt@us.ibm.comHigh 7.5

    IBM Tivoli Monitoring Portal v6 could allow a local (network adjacent) attacker to execute arbitrary commands on the system, when default client-server default communications, HTTP, are being used. IBM X-Force ID: 123493.

    Product
    Tivoli Monitoring V6
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2017IBM Tivoli Monitoring Portal V6 client could allow a local attacker to gain elevated privileges for IBM Tivoli Monitoring, caused by the default console connectCVE-2017-1181 · Other software · IBM · reported by psirt@us.ibm.comHigh 7

    IBM Tivoli Monitoring Portal V6 client could allow a local attacker to gain elevated privileges for IBM Tivoli Monitoring, caused by the default console connection not being encrypted. IBM X-Force ID: 123487.

    Product
    Tivoli Monitoring V6
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2017The re-key admin monitor was introduced in Jenkins 1.498 and re-encrypted all secrets in JENKINS_HOME with a new key.CVE-2017-1000362 · Websites & servers · Jenkins · reported by MITRECritical 9.8

    The re-key admin monitor was introduced in Jenkins 1.498 and re-encrypted all secrets in JENKINS_HOME with a new key. It also created a backup directory with all old secrets, and the key used to encrypt them. These backups were world-readable and not removed afterwards. Jenkins now deletes the backup directory, if present. Upgrading from before 1.498 will no longer create a backup directory. Administrators relying on file access permissions in their manually created backups are advised to check them for the directory $JENKINS_HOME/jenkins.security.RekeySecretAdminMonitor/backups, and delete it if present.

    Product
    Jenkins
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 11, 2017Windows Performance Monitor in Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold,CVE-2017-0170 · Computers, phones & browsers · Microsoft Corporation · reported by secure@microsoft.comMedium 6.5

    Windows Performance Monitor in Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows Server 2016 allows an information disclosure vulnerability due to the way it parses XML input, aka "Windows Performance Monitor Information Disclosure Vulnerability".

    Product
    Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8.1, Windows Server 2012 Gold and R2, Windows RT 8.1, Windows 10 Gold, 1511, 1607, 1703, and Windows
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 27, 2017IBM Tivoli Monitoring V6 could allow an unauthenticated user to access SOAP queries that could contain sensitive information.CVE-2016-6083 · Other software · IBM · reported by psirt@us.ibm.comMedium 5.3

    IBM Tivoli Monitoring V6 could allow an unauthenticated user to access SOAP queries that could contain sensitive information. IBM X-Force ID: 117696.

    Product
    Tivoli Monitoring V6
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 22, 2017In Redgate SQL Monitor before 3.10 and 4.x before 4.2, a remote attacker can gain unauthenticated access to the Base Monitor, resulting in the ability to executCVE-2015-9098 · Other software · Red-gate · reported by MITRECritical 9.8

    In Redgate SQL Monitor before 3.10 and 4.x before 4.2, a remote attacker can gain unauthenticated access to the Base Monitor, resulting in the ability to execute arbitrary SQL commands on any monitored Microsoft SQL Server machines. If the Base Monitor is connecting to these machines using an account with SQL admin privileges, then code execution on the operating system can result in full system compromise (if Microsoft SQL Server is running with local administrator privileges).

    Product
    SQL Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 8, 2017Net Monitor for Employees Pro through 5.3.4 has an unquoted service path, which allows a Security Feature Bypass of its documented "Block applications" design gCVE-2017-7180 · Other software · Eduiq · reported by MITREHigh 7.3

    Net Monitor for Employees Pro through 5.3.4 has an unquoted service path, which allows a Security Feature Bypass of its documented "Block applications" design goal. The local attacker must have privileges to write to program.exe in a protected directory, such as the %SYSTEMDRIVE% directory, and thus the issue is not interpreted as a direct privilege escalation. However, the local attacker might have the goal of executing program.exe even though program.exe is a blocked application.

    Product
    NET Monitor For Employees
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 22, 2017Untrusted search path vulnerability in Empirical Project Monitor - eXtended all versions allows remote attackers to gain privileges via a Trojan horse DLL in anCVE-2017-2175 · Other software · INFORMATION-TECHNOLOGY PROMOTION AGENCY, JAPAN (IPA) · reported by vultures@jpcert.or.jpHigh 7.8

    Untrusted search path vulnerability in Empirical Project Monitor - eXtended all versions allows remote attackers to gain privileges via a Trojan horse DLL in an unspecified directory.

    Product
    Empirical Project Monitor - eXtended
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 22, 2017Cross-site scripting vulnerability in Empirical Project Monitor - eXtended all versions allows remote attackers to inject arbitrary web script or HTML via unspeCVE-2017-2174 · Other software · INFORMATION-TECHNOLOGY PROMOTION AGENCY, JAPAN (IPA) · reported by vultures@jpcert.or.jpMedium 6.1

    Cross-site scripting vulnerability in Empirical Project Monitor - eXtended all versions allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

    Product
    Empirical Project Monitor - eXtended
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 22, 2017Cross-site scripting vulnerability in Empirical Project Monitor - eXtended all versions allows remote authenticated attackers to inject arbitrary web script or CVE-2017-2173 · Other software · INFORMATION-TECHNOLOGY PROMOTION AGENCY, JAPAN (IPA) · reported by vultures@jpcert.or.jpMedium 5.4

    Cross-site scripting vulnerability in Empirical Project Monitor - eXtended all versions allows remote authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.

    Product
    Empirical Project Monitor - eXtended
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 17, 2017Cross-site scripting (XSS) vulnerability in phpwhois 4.2.5, as used in the adsense-click-fraud-monitoring plugin 1.7.5 for WordPress, allows remote attackers toCVE-2015-3998 · WordPress plugins & themes · reported by MITREMedium 6.1

    Cross-site scripting (XSS) vulnerability in phpwhois 4.2.5, as used in the adsense-click-fraud-monitoring plugin 1.7.5 for WordPress, allows remote attackers to inject arbitrary web script or HTML via the query parameter to whois.php.

    Product
    adsense-click-fraud-monitoring
    Affected
    1.7.5 to 1.7.5
    What to do
    Affects 1.7.5 to 1.7.5. Update adsense-click-fraud-monitoring to the newest version and check its changelog mentions this fix; if there isn’t one yet, deactivate it until there is.
  • May 3, 2017Open redirect vulnerability in Opsview Monitor Pro (Prior to 5.1.0.162300841, prior to 5.0.2.27475, prior to 4.6.4.162391051, and 4.5.x without a certain 2016 sCVE-2016-10368 · Other software · Opsview · reported by MITREMedium 6.1

    Open redirect vulnerability in Opsview Monitor Pro (Prior to 5.1.0.162300841, prior to 5.0.2.27475, prior to 4.6.4.162391051, and 4.5.x without a certain 2016 security patch) allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via the back parameter to the /login URI.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 3, 2017In Opsview Monitor Pro (Prior to 5.1.0.162300841, prior to 5.0.2.27475, prior to 4.6.4.162391051, and 4.5.x without a certain 2016 security patch), an unauthentCVE-2016-10367 · Other software · Opsview · reported by MITREHigh 7.5

    In Opsview Monitor Pro (Prior to 5.1.0.162300841, prior to 5.0.2.27475, prior to 4.6.4.162391051, and 4.5.x without a certain 2016 security patch), an unauthenticated Directory Traversal vulnerability can be exploited by issuing a specially crafted HTTP GET request utilizing a simple URL encoding bypass, %252f instead of /.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 24, 2017Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Server).CVE-2017-3307 · Other software · Oracle Corporation · reported by secalert_us@oracle.comLow 3.1

    Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Server). Supported versions that are affected are 3.1.6.8003 and earlier, 3.2.1182 and earlier and 3.3.2.1162 and earlier. Difficult to exploit vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Enterprise Monitor. Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of MySQL Enterprise Monitor accessible data and unauthorized ability to cause a partial denial of service (partial DOS) of MySQL Enterprise Monitor. CVSS 3.0 Base Score 3.1 (Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:H/UI:R/S:U/C:N/I:L/A:L).

    Product
    MySQL Enterprise Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 24, 2017Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Server).CVE-2017-3306 · Other software · Oracle Corporation · reported by secalert_us@oracle.comHigh 8.3

    Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Server). Supported versions that are affected are 3.1.6.8003 and earlier, 3.2.1182 and earlier and 3.3.2.1162 and earlier. Easily "exploitable" vulnerability allows high privileged attacker with network access via multiple protocols to compromise MySQL Enterprise Monitor. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in MySQL Enterprise Monitor, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all MySQL Enterprise Monitor accessible data as well as unauthorized access to critical data or complete access to all MySQL Enterprise Monitor accessible data and unauthorized ability to cause a partial denial of service (partial DOS) of MySQL Enterprise Monitor. CVSS 3.0 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:L).

    Product
    MySQL Enterprise Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2017The Human Monitor Interface support in QEMU allows remote attackers to cause a denial of service (out-of-bounds write and application crash).CVE-2015-8619 · Other software · Qemu · reported by Red HatHigh 7.5

    The Human Monitor Interface support in QEMU allows remote attackers to cause a denial of service (out-of-bounds write and application crash).

    Product
    Qemu
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 9, 2017Paessler PRTG before 16.2.24.4045 has XSS via SNMP.CVE-2016-5078 · Other software · Paessler · reported by cret@cert.orgMedium 6.1

    Paessler PRTG before 16.2.24.4045 has XSS via SNMP.

    Product
    Prtg Network Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 9, 2017Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to gain privileges via manual entry of a Settings URL.CVE-2015-2889 · Other software · Summerinfant · reported by cret@cert.orgHigh 8.8

    Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to gain privileges via manual entry of a Settings URL.

    Product
    Baby Zoom Wifi Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 9, 2017Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.CVE-2015-2888 · Other software · Summerinfant · reported by cret@cert.orgCritical 9.8

    Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service.

    Product
    Baby Zoom Wifi Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 9, 2017iBaby M3S has a password of admin for the backdoor admin account.CVE-2015-2887 · Other software · Ibaby · reported by cret@cert.orgCritical 9.8

    iBaby M3S has a password of admin for the backdoor admin account.

    Product
    M3s Baby Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 9, 2017iBaby M6 allows remote attackers to obtain sensitive information, related to the ibabycloud.com service.CVE-2015-2886 · Other software · Ibaby · reported by cret@cert.orgHigh 7.5

    iBaby M6 allows remote attackers to obtain sensitive information, related to the ibabycloud.com service.

    Product
    M6 Baby Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2017Due to a lack of standard encryption when transmitting sensitive information over the internet to a centralized monitoring service, the Eview EV-07S GPS TrackerCVE-2017-5239 · Other software · Eview · reported by cve@rapid7.comHigh 7.5

    Due to a lack of standard encryption when transmitting sensitive information over the internet to a centralized monitoring service, the Eview EV-07S GPS Tracker discloses personally identifying information, such as GPS data and IMEI numbers, to any man-in-the-middle (MitM) listener.

    Product
    EV-07S GPS Tracker
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 23, 2017A missing X-Frame-Options header in the NDS Utility Monitor in NDSD in Novell eDirectory before 9.0.2 could be used by remote attackers for clickjacking.CVE-2016-9168 · Other software · Novell · reported by security@opentext.comMedium 6.5

    A missing X-Frame-Options header in the NDS Utility Monitor in NDSD in Novell eDirectory before 9.0.2 could be used by remote attackers for clickjacking.

    Product
    Edirectory
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 20, 2017The get_sessions servlet in CA Unified Infrastructure Management (formerly CA Nimsoft Monitor) before 8.5 and CA Unified Infrastructure Management Snap (formerlCVE-2016-9165 · Other software · CA · reported by MITREHigh 7.5

    The get_sessions servlet in CA Unified Infrastructure Management (formerly CA Nimsoft Monitor) before 8.5 and CA Unified Infrastructure Management Snap (formerly CA Nimsoft Monitor Snap) allows remote attackers to obtain active session ids and consequently bypass authentication or gain privileges via unspecified vectors.

    Product
    Unified Infrastructure Management
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 8, 2017IBM Tivoli Monitoring 6.2 and 6.3 is vulnerable to possible host header injection attack that could lead to HTTP cache poisoning or firewall bypass.CVE-2016-5933 · Other software · IBM Corporation · reported by psirt@us.ibm.comMedium 4.6

    IBM Tivoli Monitoring 6.2 and 6.3 is vulnerable to possible host header injection attack that could lead to HTTP cache poisoning or firewall bypass. IBM Reference #: 1997223.

    Product
    Tivoli Monitoring V6
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 7, 2017Directory traversal vulnerability in diag.jsp file in CA Unified Infrastructure Management (formerly CA Nimsoft Monitor) 8.4 SP1 and earlier and CA Unified InfrCVE-2016-9164 · Other software · CA · reported by MITREHigh 7.5

    Directory traversal vulnerability in diag.jsp file in CA Unified Infrastructure Management (formerly CA Nimsoft Monitor) 8.4 SP1 and earlier and CA Unified Infrastructure Management Snap (formerly CA Nimsoft Monitor Snap) allows remote attackers to read arbitrary files via unspecified vectors.

    Product
    Unified Infrastructure Management
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 22, 2017Munin before 2.999.6 has a local file write vulnerability when CGI graphs are enabled.CVE-2017-6188 · Other software · Munin-monitoring · reported by MITREMedium 5.5

    Munin before 2.999.6 has a local file write vulnerability when CGI graphs are enabled. Setting multiple upper_limit GET parameters allows overwriting any file accessible to the www-data user.

    Product
    Munin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2017An issue was discovered in Emoncms through 9.8.0.CVE-2017-5964 · Other software · Openenergymonitor · reported by MITREMedium 6.1

    An issue was discovered in Emoncms through 9.8.0. The vulnerability exists due to insufficient filtration of user-supplied data in multiple HTTP GET parameters passed to the "emoncms-master/Modules/vis/visualisations/compare.php" URL. An attacker could execute arbitrary HTML and script code in a browser in the context of the vulnerable website.

    Product
    Emoncms
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 1, 2017IBM Security Guardium Database Activity Monitor appliance could allow a local user to inject commands that would be executed as root.CVE-2016-6065 · Other software · IBM Corporation · reported by psirt@us.ibm.comHigh 7.8

    IBM Security Guardium Database Activity Monitor appliance could allow a local user to inject commands that would be executed as root.

    Product
    Guardium
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2017Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Agent).CVE-2016-5590 · Other software · Oracle · reported by secalert_us@oracle.comHigh 7.2

    Vulnerability in the MySQL Enterprise Monitor component of Oracle MySQL (subcomponent: Monitoring: Agent). Supported versions that are affected are 3.1.3.7856 and earlier. Easily exploitable vulnerability allows high privileged attacker with network access via TLS to compromise MySQL Enterprise Monitor. Successful attacks of this vulnerability can result in takeover of MySQL Enterprise Monitor. CVSS v3.0 Base Score 7.2 (Confidentiality, Integrity and Availability impacts).

    Product
    MySQL Enterprise Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 23, 2017XML external entity vulnerability in PRTG Network Monitor before 16.2.23.3077/3078 allows remote authenticated users to read arbitrary files by creating a new HCVE-2015-7743 · Other software · Paessler · reported by MITREMedium 6.5

    XML external entity vulnerability in PRTG Network Monitor before 16.2.23.3077/3078 allows remote authenticated users to read arbitrary files by creating a new HTTP XML/REST Value sensor that accesses a crafted XML file.

    Product
    Prtg Network Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 20, 2017In Moodle 2.x and 3.x, an unenrolled user still receives event monitor notifications even though they can no longer access the course.CVE-2016-5014 · Other software · Moodle · reported by MITREMedium 5.4

    In Moodle 2.x and 3.x, an unenrolled user still receives event monitor notifications even though they can no longer access the course.

    Product
    Moodle
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 14, 2017A Directory Traversal vulnerability in CliMonitorReportServlet in the Brocade Network Advisor versions released prior to and including 14.0.2 could allow remoteCVE-2016-8207 · Other software · Brocade · reported by sirt@brocade.comHigh 7.5

    A Directory Traversal vulnerability in CliMonitorReportServlet in the Brocade Network Advisor versions released prior to and including 14.0.2 could allow remote attackers to read arbitrary files including files with sensitive user information.

    Product
    Network Advisor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 8, 2016In BlueZ 5.42, an out-of-bounds read was identified in "packet_hexdump" function in "monitor/packet.c" source file.CVE-2016-9918 · Other software · Bluez Project · reported by MITREHigh 7.5

    In BlueZ 5.42, an out-of-bounds read was identified in "packet_hexdump" function in "monitor/packet.c" source file. This issue can be triggered by processing a corrupted dump file and will result in btmon crash.

    Product
    Bluez
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 3, 2016In BlueZ 5.42, a buffer over-read was identified in "l2cap_packet" function in "monitor/packet.c" source file.CVE-2016-9802 · Other software · Bluez · reported by MITREMedium 5.3

    In BlueZ 5.42, a buffer over-read was identified in "l2cap_packet" function in "monitor/packet.c" source file. This issue can be triggered by processing a corrupted dump file and will result in btmon crash.

    Product
    Bluez
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 1, 2016Stack-based buffer overflow in the ax Shared Libraries in the Agent in IBM Tivoli Monitoring (ITM) 6.2.2 before FP9, 6.2.3 before FP5, and 6.3.0 before FP2 on LCVE-2016-2946 · Other software · IBM · reported by psirt@us.ibm.comHigh 7.8

    Stack-based buffer overflow in the ax Shared Libraries in the Agent in IBM Tivoli Monitoring (ITM) 6.2.2 before FP9, 6.2.3 before FP5, and 6.3.0 before FP2 on Linux and UNIX allows local users to gain privileges via unspecified vectors.

    Product
    Tivoli Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.