Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 7 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,762exploited flaws on CISA’s list
34added in the last 30 days
344new WordPress flaws this week
390,080entries in the database

415 results · page 3 of 9

  • Mar 7, 2025An issue was discovered in the Masquerade module before 1.x-1.0.1 for Backdrop CMS.CVE-2025-27822 · Other software · backdropcms · reported by MITREHigh 7.5

    An issue was discovered in the Masquerade module before 1.x-1.0.1 for Backdrop CMS. It allows people to temporarily switch to another user account. The module provides a "Masquerade as admin" permission to restrict people (who can masquerade) from switching to an account with administrative privileges. This permission is not always honored and may allow non-administrative users to masquerade as an administrator. This vulnerability is mitigated by the fact that an attacker must have a role with the "Masquerade as user" permission.

    Product
    Masquerade
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 10, 2025Vulnerability in the OPC UA .NET Standard Stack before 1.5.374.158 allows an unauthorized attacker to bypass application authentication when using HTTPS endpoinCVE-2024-42513 · Other software · Siemens · reported by MITREMedium 5.3

    Vulnerability in the OPC UA .NET Standard Stack before 1.5.374.158 allows an unauthorized attacker to bypass application authentication when using HTTPS endpoints.

    Product
    Industrial Edge for Machine Tools (formerly known as "SINUMERIK Edge")
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 10, 2025Vulnerability in the OPC UA .NET Standard Stack before 1.5.374.158 allows an unauthorized attacker to bypass application authentication when the deprecated BasiCVE-2024-42512 · Other software · Siemens · reported by MITREHigh 8.6

    Vulnerability in the OPC UA .NET Standard Stack before 1.5.374.158 allows an unauthorized attacker to bypass application authentication when the deprecated Basic128Rsa15 security policy is enabled.

    Product
    SIMATIC Energy Manager PRO V7.2
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2025A prototype pollution in the function fieldsToJson of node-opcua-alarm-condition v2.134.0 allows attackers to cause a Denial of Service (DoS) via supplying a crCVE-2024-57086 · Other software · reported by MITREHigh 7.5

    A prototype pollution in the function fieldsToJson of node-opcua-alarm-condition v2.134.0 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload.

    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 2, 2025An XSS issue was discovered in Backdrop CMS 1.28.x before 1.28.5 and 1.29.x before 1.29.3.CVE-2025-25063 · Other software · backdropcms · reported by MITREMedium 4.4

    An XSS issue was discovered in Backdrop CMS 1.28.x before 1.28.5 and 1.29.x before 1.29.3. It does not sufficiently validate uploaded SVG images to ensure they do not contain potentially dangerous SVG tags. SVG images can contain clickable links and executable scripting, and using a crafted SVG, it is possible to execute scripting in the browser when an SVG image is viewed. This issue is mitigated by the attacker needing to be able to upload SVG images, and that Backdrop embeds all uploaded SVG images within <img> tags, which prevents scripting from executing. The SVG must be viewed directly by its URL in order to run any embedded scripting.

    Product
    backdrop
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 2, 2025An XSS issue was discovered in Backdrop CMS 1.28.x before 1.28.5 and 1.29.x before 1.29.3.CVE-2025-25062 · Other software · backdropcms · reported by MITREMedium 4.4

    An XSS issue was discovered in Backdrop CMS 1.28.x before 1.28.5 and 1.29.x before 1.29.3. It doesn't sufficiently isolate long text content when the CKEditor 5 rich text editor is used. This allows a potential attacker to craft specialized HTML and JavaScript that may be executed when an administrator attempts to edit a piece of content. This vulnerability is mitigated by the fact that an attacker must have the ability to create long text content (such as through the node or comment forms) and an administrator must edit (not view) the content that contains the malicious content. This problem only exists when using the CKEditor 5 module.

    Product
    backdrop
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 6, 2025Information disclosure while invoking callback function of sound model driver from ADSP for every valid opcode received from sound model driver.CVE-2024-33067 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comMedium 6.1

    Information disclosure while invoking callback function of sound model driver from ADSP for every valid opcode received from sound model driver.

    Product
    Snapdragon
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 16, 2024A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter QuCVE-2024-49775 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 2, 2024An “Authentication Bypass Using an Alternate Path or Channel” vulnerability in the OPC UA Server configuration required for B&R mapp Cockpit before 6.0, B&R mapCVE-2024-10490 · Other software · B&R Industrial Automation GmbH · reported by cybersecurity@ch.abb.comHigh 8.4

    An “Authentication Bypass Using an Alternate Path or Channel” vulnerability in the OPC UA Server configuration required for B&R mapp Cockpit before 6.0, B&R mapp View before 6.0, B&R mapp Services before 6.0, B&R mapp Motion before 6.0 and B&R mapp Vision before 6.0 may be used by an unauthenticated network-based attacker to cause information disclosure, unintended change of data, or denial of service conditions. B&R mapp Services is only affected, when mpUserX or mpCodeBox are used in the Automation Studio project.

    Product
    B&R mapp Cockpit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 28, 2024Backdrop CMS before 1.28.4 and 1.29.x before 1.29.2 allows XSS via an SVG document, if the SVG tag is allowed for a text format.CVE-2024-54123 · Other software · Backdropcms · reported by MITREMedium 6.1

    Backdrop CMS before 1.28.4 and 1.29.x before 1.29.2 allows XSS via an SVG document, if the SVG tag is allowed for a text format.

    Product
    Backdrop CMS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 12, 2024The NVMe driver function nvme_opc_get_log_page is vulnerable to a buffer over-read from a guest-controlled value.CVE-2024-51562 · Other software · FreeBSD · reported by secteam@freebsd.orgMedium 6.5

    The NVMe driver function nvme_opc_get_log_page is vulnerable to a buffer over-read from a guest-controlled value.

    Product
    FreeBSD
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 22, 2024An issue was discovered in OPC Foundation OPCFoundation/UA-.NETStandard through 1.5.374.78.CVE-2024-45526 · Other software · opcfoundation · reported by MITREMedium 5.3

    An issue was discovered in OPC Foundation OPCFoundation/UA-.NETStandard through 1.5.374.78. A remote attacker can send requests with invalid credentials and cause the server performance to degrade gradually.

    Product
    ua-.netstandard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 10, 2024A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATCVE-2024-33698 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3

    A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.

    Product
    Opcenter Quality
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2024The ctl_report_supported_opcodes function did not sufficiently validate a field provided by userspace, allowing an arbitrary write to a limited amount of kernelCVE-2024-42416 · Other software · FreeBSD · reported by secteam@freebsd.orgHigh 8.8

    The ctl_report_supported_opcodes function did not sufficiently validate a field provided by userspace, allowing an arbitrary write to a limited amount of kernel help memory. Malicious software running in a guest VM that exposes virtio_scsi can exploit the vulnerabilities to achieve code execution on the host in the bhyve userspace process, which typically runs as root. Note that bhyve runs in a Capsicum sandbox, so malicious code is constrained by the capabilities available to the bhyve process. A malicious iSCSI initiator could achieve remote code execution on the iSCSI target host.

    Product
    FreeBSD
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 22, 2024Backdrop CMS before 1.27.3 and 1.28.x before 1.28.2 does not sufficiently sanitize field labels before they are displayed in certain places.CVE-2024-41709 · Other software · Backdropcms · reported by MITREMedium 4.8

    Backdrop CMS before 1.27.3 and 1.28.x before 1.28.2 does not sufficiently sanitize field labels before they are displayed in certain places. This vulnerability is mitigated by the fact that an attacker must have a role with the "administer fields" permission.

    Product
    Backdrop
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 9, 2024Nopcommerce 4.70.1 is vulnerable to Cross Site Scripting (XSS) via the combined "AddProductReview.Title" and "AddProductReview.ReviewText" parameter(s) (ReviewsCVE-2024-38963 · Websites & servers · nopcommerce · reported by MITREMedium 6.1

    Nopcommerce 4.70.1 is vulnerable to Cross Site Scripting (XSS) via the combined "AddProductReview.Title" and "AddProductReview.ReviewText" parameter(s) (Reviews) when creating a new review.

    Product
    nopcommerce
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 5, 2024A buffer-management vulnerability in OPC Foundation OPCFoundation.NetStandard.Opc.Ua.Core before 1.05.374.54 could allow remote attackers to exhaust memory resoCVE-2024-33862 · Other software · opcfoundation · reported by MITREHigh 7.5

    A buffer-management vulnerability in OPC Foundation OPCFoundation.NetStandard.Opc.Ua.Core before 1.05.374.54 could allow remote attackers to exhaust memory resources. It is triggered when the system receives an excessive number of messages from a remote source. This could potentially lead to a denial of service (DoS) condition, disrupting the normal operation of the system.

    Product
    ua-.netstandard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 4, 2024An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorreCVE-2024-5000 · Other software · CODESYS · reported by info@cert.vde.comHigh 7.5

    An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.

    Product
    CODESYS Control for BeagleBone SL
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 7, 2024OPC Foundation UA .NET Standard ConditionRefresh Resource Exhaustion Denial-of-Service Vulnerability.CVE-2023-27321 · Other software · OPC Foundation · reported by zdi-disclosures@trendmicro.comHigh 7.5

    OPC Foundation UA .NET Standard ConditionRefresh Resource Exhaustion Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of OPC Foundation UA .NET Standard. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OPC UA ConditionRefresh requests. By sending a large number of requests, an attacker can consume all available resources on the server. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20505.

    Product
    UA .NET Standard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Softing Secure Integration Server FileDirectory OPC UA Object Arbitrary File Creation Vulnerability.CVE-2023-39480 · Other software · Softing · reported by zdi-disclosures@trendmicro.comMedium 6.5

    Softing Secure Integration Server FileDirectory OPC UA Object Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of FileDirectory OPC UA Objects. The issue results from allowing unauthorized access to the filesystem. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20549.

    Product
    Secure Integration Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Softing Secure Integration Server OPC UA Gateway Directory Creation Vulnerability.CVE-2023-39479 · Other software · Softing · reported by zdi-disclosures@trendmicro.comHigh 8.8

    Softing Secure Integration Server OPC UA Gateway Directory Creation Vulnerability. This vulnerability allows remote attackers to create directories on affected installations of Softing Secure Integration Server. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the handling of FileDirectory OPC UA Objects. The issue results from allowing unauthorized access to the filesystem. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of root. Was ZDI-CAN-20548.

    Product
    Secure Integration Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability.CVE-2023-38124 · Other software · Inductive Automation · reported by zdi-disclosures@trendmicro.comHigh 8.8

    Inductive Automation Ignition OPC UA Quick Client Task Scheduling Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is required to exploit this vulnerability. The specific flaw exists within the Ignition Gateway server. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20541.

    Product
    Ignition
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability.CVE-2023-38123 · Other software · Inductive Automation · reported by zdi-disclosures@trendmicro.comHigh 8.8

    Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540.

    Product
    Ignition
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability.CVE-2023-38122 · Other software · Inductive Automation · reported by zdi-disclosures@trendmicro.comHigh 7.2

    Inductive Automation Ignition OPC UA Quick Client Permissive Cross-domain Policy Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the configuration of the web server. The issue results from the lack of appropriate Content Security Policy headers. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of SYSTEM. Was ZDI-CAN-20539.

    Product
    Ignition
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability.CVE-2023-38121 · Other software · Inductive Automation · reported by zdi-disclosures@trendmicro.comCritical 9

    Inductive Automation Ignition OPC UA Quick Client Cross-Site Scripting Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of the id parameter provided to the Inductive Automation Ignition web interface. The issue results from the lack of proper validation of user-supplied data, which can lead to the injection of an arbitrary script. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-20355.

    Product
    Ignition
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Unified Automation UaGateway NodeManagerOpcUa Use-After-Free Remote Code Execution Vulnerability.CVE-2023-32174 · Other software · Unified Automation · reported by zdi-disclosures@trendmicro.comCritical 9.1

    Unified Automation UaGateway NodeManagerOpcUa Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Unified Automation UaGateway. Authentication is required to exploit this vulnerability when the product is in its default configuration. The specific flaw exists within the handling of NodeManagerOpcUa objects. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. . Was ZDI-CAN-20577.

    Product
    UaGateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Unified Automation UaGateway OPC UA Server Use-After-Free Denial-of-Service Vulnerability.CVE-2023-32172 · Other software · Unified Automation · reported by zdi-disclosures@trendmicro.comMedium 6.5

    Unified Automation UaGateway OPC UA Server Use-After-Free Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation UaGateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the implementation of the ImportXML function. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20497.

    Product
    UaGateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Unified Automation UaGateway OPC UA Server Null Pointer Dereference Denial-of-Service Vulnerability.CVE-2023-32171 · Other software · Unified Automation · reported by zdi-disclosures@trendmicro.comMedium 6.5

    Unified Automation UaGateway OPC UA Server Null Pointer Dereference Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation UaGateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the ImportCsv method. A crafted XML payload can cause a null pointer dereference. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20495.

    Product
    UaGateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Unified Automation UaGateway OPC UA Server Improper Input Validation Denial-of-Service Vulnerability.CVE-2023-32170 · Other software · Unified Automation · reported by zdi-disclosures@trendmicro.comMedium 6.5

    Unified Automation UaGateway OPC UA Server Improper Input Validation Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation UaGateway. User interaction is required to exploit this vulnerability in that the target must choose to accept a client certificate. The specific flaw exists within the processing of client certificates. The issue results from the lack of proper validation of certificate data. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20494.

    Product
    UaGateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2024Softing edgeConnector Siemens OPC UA Server Null Pointer Dereference Denial-of-Service Vulnerability.CVE-2023-27336 · Other software · Softing · reported by zdi-disclosures@trendmicro.comHigh 7.5

    Softing edgeConnector Siemens OPC UA Server Null Pointer Dereference Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Softing edgeConnector Siemens. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of OPC client certificates. The issue results from dereferencing a NULL pointer. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-20508.

    Product
    edgeConnector Siemens
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 17, 2024In the Linux kernel, the following vulnerability has been resolved: platform/x86: think-lmi: Fix password opcode ordering for workstations The Lenovo workstatCVE-2024-26836 · Computers, phones & browsers · Linux · reported by 416baaa9-dc9f-4396-8d5f-8c081fb06d67High 7.8

    In the Linux kernel, the following vulnerability has been resolved: platform/x86: think-lmi: Fix password opcode ordering for workstations The Lenovo workstations require the password opcode to be run before the attribute value is changed (if Admin password is enabled). Tested on some Thinkpads to confirm they are OK with this order too.

    Product
    Linux
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 2, 2024In the Linux kernel, the following vulnerability has been resolved: scsi: pm80xx: Avoid leaking tags when processing OPC_INB_SET_CONTROLLER_CONFIG command TagCVE-2023-52500 · Computers, phones & browsers · Linux · reported by 416baaa9-dc9f-4396-8d5f-8c081fb06d67Medium 5.5

    In the Linux kernel, the following vulnerability has been resolved: scsi: pm80xx: Avoid leaking tags when processing OPC_INB_SET_CONTROLLER_CONFIG command Tags allocated for OPC_INB_SET_CONTROLLER_CONFIG command need to be freed when we receive the response.

    Product
    Linux
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 16, 2024 OPCUAServerToolkit will write a log message once an OPC UA client has successfully connected containing the client's self-defined description field.CVE-2023-7234 · Other software · Integration Objects · reported by ics-cert@hq.dhs.govMedium 5.3

    OPCUAServerToolkit will write a log message once an OPC UA client has successfully connected containing the client's self-defined description field.

    Product
    OPC UA Server Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 2, 2024The Priva TopControl Suite contains predictable credentials for the SSH service, based on the Serial number.CVE-2022-3010 · Other software · Priva · reported by csirt@divd.nlHigh 7.5

    The Priva TopControl Suite contains predictable credentials for the SSH service, based on the Serial number. Which makes it possible for an attacker to calculate the login credentials for the Priva TopControll suite.

    Product
    TopControl Suite - Bacnet
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 14, 2023An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wanCVE-2023-41151 · Other software · Softing · reported by MITREHigh 7.5

    An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wants to send an error packet, while socket is blocked on writing.

    Product
    OPC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023The OPC UA .NET Standard Reference Server before 1.4.371.86.CVE-2023-31048 · Other software · Opcfoundation · reported by MITREMedium 5.3

    The OPC UA .NET Standard Reference Server before 1.4.371.86. places sensitive information into an error message that may be seen remotely.

    Product
    Ua-.netstandard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versiCVE-2023-46285 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versiCVE-2023-46284 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versiCVE-2023-46283 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versiCVE-2023-46282 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 12, 2023A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versiCVE-2023-46281 · Other software · Siemens · reported by productcert@siemens.comHigh 7.1

    A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). When accessing the UMC Web-UI from affected products, UMC uses an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior.

    Product
    Opcenter Execution Foundation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 5, 2023Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery sCVE-2023-37572 · Other software · Softing · reported by MITREHigh 7.5

    Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery service. The service executable could be changed or the service could be deleted.

    Product
    OPC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 4, 2023Memory corruption in BT controller while parsing debug commands with specific sub-opcodes at HCI interface level.CVE-2023-28587 · Computers, phones & browsers · Qualcomm, Inc. · reported by product-security@qualcomm.comHigh 7.8

    Memory corruption in BT controller while parsing debug commands with specific sub-opcodes at HCI interface level.

    Product
    Snapdragon
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 14, 2023A vulnerability has been identified in Siemens OPC UA Modelling Editor (SiOME) (All versions < V2.8).CVE-2023-46590 · Other software · Siemens · reported by productcert@siemens.comHigh 7.5

    A vulnerability has been identified in Siemens OPC UA Modelling Editor (SiOME) (All versions < V2.8). Affected products suffer from a XML external entity (XXE) injection vulnerability. This vulnerability could allow an attacker to interfere with an application's processing of XML data and read arbitrary files in the system.

    Product
    Siemens OPC UA Modelling Editor (SiOME)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 3, 2023Versions of the package asyncua before 0.9.96 are vulnerable to Denial of Service (DoS) such that an attacker can send a malformed packet and as a result, the sCVE-2023-26151 · Other software · Freeopcua · reported by report@snyk.ioMedium 5.3

    Versions of the package asyncua before 0.9.96 are vulnerable to Denial of Service (DoS) such that an attacker can send a malformed packet and as a result, the server will enter into an infinite loop and consume excessive memory.

    Product
    Opcua-asyncio
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 3, 2023Versions of the package asyncua before 0.9.96 are vulnerable to Improper Authentication such that it is possible to access Address Space without encryption and CVE-2023-26150 · Other software · Freeopcua · reported by report@snyk.ioMedium 6.5

    Versions of the package asyncua before 0.9.96 are vulnerable to Improper Authentication such that it is possible to access Address Space without encryption and authentication. **Note:** This issue is a result of missing checks for services that require an active session.

    Product
    Opcua-asyncio
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 12, 2023The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinCVE-2023-28831 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7

    The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.

    Product
    SIMATIC BRAUMAT
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 22, 2023GNU Binutils before 2.34 has an uninitialized-heap vulnerability in function tic4x_print_cond (file opcodes/tic4x-dis.c) which could allow attackers to make an CVE-2020-35342 · Other software · GNU · reported by MITREHigh 7.5

    GNU Binutils before 2.34 has an uninitialized-heap vulnerability in function tic4x_print_cond (file opcodes/tic4x-dis.c) which could allow attackers to make an information leak.

    Product
    Binutils
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 28, 2023A vulnerability was found in AO-OPC server versions mentioned above.CVE-2023-2685 · Other software · ABB · reported by cybersecurity@ch.abb.comHigh 7.2

    A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges. It is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders. An update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1 

    Product
    AO-OPC
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 12, 2023 A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file onCVE-2023-37200 · Other software · Schneider Electric · reported by cybersecurity@se.comMedium 5.5

    A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.

    Product
    EcoStruxure OPC UA Server Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.