Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 6 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
36added in the last 30 days
584new WordPress flaws this week
391,288entries in the database

1,743 results · page 28 of 35

  • Oct 23, 2018A potential Remote Arbitrary Code Execution vulnerability has been identified in Micro Focus' Real User Monitoring software, versions 9.26IP, 9.30, 9.40 and 9.5CVE-2018-18589 · Other software · Micro Focus · reported by security@opentext.comMedium 6.3

    A potential Remote Arbitrary Code Execution vulnerability has been identified in Micro Focus' Real User Monitoring software, versions 9.26IP, 9.30, 9.40 and 9.50. The vulnerability could be exploited to execute arbitrary code.

    Product
    Microfocus Real User Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 21, 2018ServersCheck Monitoring Software before 14.3.4 allows SQL Injection by an authenticated user.CVE-2018-18550 · Other software · Serverscheck · reported by MITREHigh 8.8

    ServersCheck Monitoring Software before 14.3.4 allows SQL Injection by an authenticated user.

    Product
    Serverscheck
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 16, 2018Vulnerability in the PeopleSoft Enterprise PeopleTools component of Oracle PeopleSoft Products (subcomponent: Performance Monitor).CVE-2018-3202 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 5.3

    Vulnerability in the PeopleSoft Enterprise PeopleTools component of Oracle PeopleSoft Products (subcomponent: Performance Monitor). Supported versions that are affected are 8.55 and 8.56. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise PeopleSoft Enterprise PeopleTools. Successful attacks of this vulnerability can result in unauthorized read access to a subset of PeopleSoft Enterprise PeopleTools accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

    Product
    PeopleSoft Enterprise PT PeopleTools
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 16, 2018Vulnerability in the Application Management Pack for Oracle E-Business Suite component of Oracle E-Business Suite (subcomponent: User Monitoring).CVE-2018-3167 · Other software · Oracle Corporation · reported by secalert_us@oracle.comMedium 5.3

    Vulnerability in the Application Management Pack for Oracle E-Business Suite component of Oracle E-Business Suite (subcomponent: User Monitoring). Supported versions that are affected are 12.1.3, 12.2.3, 12.2.4, 12.2.5, 12.2.6 and 12.2.7. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Application Management Pack for Oracle E-Business Suite. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Application Management Pack for Oracle E-Business Suite accessible data. CVSS 3.0 Base Score 5.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

    Product
    Application Management Pack for Oracle E-Business Suite
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 16, 2018Vulnerability in the Oracle GoldenGate component of Oracle GoldenGate (subcomponent: Monitoring Manager).CVE-2018-2913 · Other software · Oracle Corporation · reported by secalert_us@oracle.comCritical 10

    Vulnerability in the Oracle GoldenGate component of Oracle GoldenGate (subcomponent: Monitoring Manager). Supported versions that are affected are 12.1.2.1.0, 12.2.0.2.0 and 12.3.0.1.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via TCP to compromise Oracle GoldenGate. While the vulnerability is in Oracle GoldenGate, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Oracle GoldenGate. Note: For Linux and Windows platforms, the CVSS score is 9.0 with Access Complexity as High. For all other platforms, the cvss score is 10.0. CVSS 3.0 Base Score 10.0 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

    Product
    GoldenGate
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 5, 2018A vulnerability in Cisco IOS ROM Monitor (ROMMON) Software for Cisco Catalyst 6800 Series Switches could allow an unauthenticated, local attacker to bypass CiscCVE-2018-15370 · Network & remote access · Cisco · reported by psirt@cisco.comMedium 6.8

    A vulnerability in Cisco IOS ROM Monitor (ROMMON) Software for Cisco Catalyst 6800 Series Switches could allow an unauthenticated, local attacker to bypass Cisco Secure Boot validation checks and load a compromised software image on an affected device. The vulnerability is due to the presence of a hidden command in the affected software. An attacker could exploit this vulnerability by connecting to an affected device via the console, forcing the device into ROMMON mode, and writing a malicious pattern to a specific memory address on the device. A successful exploit could allow the attacker to bypass signature validation checks by Cisco Secure Boot technology and load a compromised software image on the affected device. A compromised software image is any software image that has not been digitally signed by Cisco.

    Product
    Cisco Catalyst 6800 Series Switches
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 26, 2018IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL CVE-2018-16713 · Other software · Iobit · reported by MITREMedium 6.5

    IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.

    Product
    Advanced Systemcare
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 26, 2018IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send a specialCVE-2018-16712 · Other software · Iobit · reported by MITREMedium 6.5

    IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send a specially crafted IOCTL 0x9C406104 to read physical memory.

    Product
    Advanced Systemcare
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 26, 2018IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL CVE-2018-16711 · Other software · Iobit · reported by MITREHigh 8.8

    IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402088) with a buffer containing user defined content. The driver's subroutine will execute a wrmsr instruction with the user's buffer for input.

    Product
    Advanced Systemcare
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 19, 2018Elasticsearch Alerting and Monitoring in versions before 6.4.1 or 5.6.12 have an information disclosure issue when secrets are configured via the API.CVE-2018-3831 · Other software · Elastic · reported by security@elastic.coHigh 8.8

    Elasticsearch Alerting and Monitoring in versions before 6.4.1 or 5.6.12 have an information disclosure issue when secrets are configured via the API. The Elasticsearch _cluster/settings API, when queried, could leak sensitive configuration information such as passwords, tokens, or usernames. This could allow an authenticated Elasticsearch user to improperly view these details.

    Product
    Elasticsearch
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 19, 2018IBM Tivoli Monitoring 6.2.3 through 6.2.3.5 and 6.3.0 through 6.3.0.7 are vulnerable to both TEPS user privilege escalation and possible denial of service due tCVE-2017-1794 · Other software · IBM · reported by psirt@us.ibm.comHigh 7.5

    IBM Tivoli Monitoring 6.2.3 through 6.2.3.5 and 6.3.0 through 6.3.0.7 are vulnerable to both TEPS user privilege escalation and possible denial of service due to unconstrained memory growth. IBM X-Force ID: 137039.

    Product
    Tivoli Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 10, 2018Monit before version 5.20.0 is vulnerable to a cross site request forgery attack.CVE-2016-7067 · Other software · Tildeslash Ltd. · reported by Red HatMedium 6.5

    Monit before version 5.20.0 is vulnerable to a cross site request forgery attack. Successful exploitation will enable an attacker to disable/enable all monitoring for a particular host or disable/enable monitoring for a specific service.

    Product
    monit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2018The diagnosticsb2ksy parameter of the /rest endpoint in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to Cross-Site Scripting.CVE-2018-16148 · Other software · Opsview · reported by MITREMedium 6.1

    The diagnosticsb2ksy parameter of the /rest endpoint in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to Cross-Site Scripting.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2018The data parameter of the /settings/api/router endpoint in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to Cross-Site Scripting.CVE-2018-16147 · Other software · Opsview · reported by MITREMedium 6.1

    The data parameter of the /settings/api/router endpoint in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to Cross-Site Scripting.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2018The web management console of Opsview Monitor 5.4.x before 5.4.2 provides functionality accessible by an authenticated administrator to test notifications that CVE-2018-16146 · Other software · Opsview · reported by MITREHigh 7.2

    The web management console of Opsview Monitor 5.4.x before 5.4.2 provides functionality accessible by an authenticated administrator to test notifications that are triggered under certain configurable events. The value parameter is not properly sanitized, leading to arbitrary command injection with the privileges of the nagios user account.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2018The /etc/init.d/opsview-reporting-module script that runs at boot time in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 invokes a file that can be edited CVE-2018-16145 · Other software · Opsview · reported by MITREHigh 8.1

    The /etc/init.d/opsview-reporting-module script that runs at boot time in Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 invokes a file that can be edited by the nagios user, and would allow attackers to elevate their privileges to root after a system restart, hence obtaining full control of the appliance.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 5, 2018The test connection functionality in the NetAudit section of Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to command injection due to improCVE-2018-16144 · Other software · Opsview · reported by MITRECritical 9.8

    The test connection functionality in the NetAudit section of Opsview Monitor before 5.3.1 and 5.4.x before 5.4.2 is vulnerable to command injection due to improper sanitization of the rancid_password parameter.

    Product
    Opsview
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 28, 2018A command injection vulnerability in maintenance.cgi in Mutiny "Monitoring Appliance" before 6.1.0-5263 allows authenticated users, with access to the admin intCVE-2018-15529 · Other software · Mutiny · reported by MITREHigh 8.8

    A command injection vulnerability in maintenance.cgi in Mutiny "Monitoring Appliance" before 6.1.0-5263 allows authenticated users, with access to the admin interface, to inject arbitrary commands within the filename of a system upgrade upload.

    Product
    Mutiny
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2018An issue was discovered in post2file.php in Up.Time Monitoring Station 7.5.0 (build 16) and 7.4.0 (build 13).CVE-2015-9263 · Other software · Idera · reported by MITRECritical 9.8

    An issue was discovered in post2file.php in Up.Time Monitoring Station 7.5.0 (build 16) and 7.4.0 (build 13). It allows an attacker to upload an arbitrary file, such as a .php file that can execute arbitrary OS commands.

    Product
    Uptime Infrastructure Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 26, 2018Plainview Activity Monitor plugin before 20180826: OS command injectionCVE-2018-15877 · WordPress plugins & themes · reported by MITREHigh 8.8

    The Plainview Activity Monitor plugin before 20180826 for WordPress is vulnerable to OS command injection via shell metacharacters in the ip parameter of a wp-admin/admin.php?page=plainview_activity_monitor&tab=activity_tools request.

    Product
    Plainview Activity Monitor plugin before 20180826
    Fixed in
    20180826
    What to do
    Update Plainview Activity Monitor plugin before 20180826 to 20180826 or newer.
  • Aug 24, 2018The D-Link EyeOn Baby Monitor (DCS-825L) 1.08.1 has multiple command injection vulnerabilities in the web service framework.CVE-2017-11564 · Other software · Dlink · reported by MITREHigh 8.8

    The D-Link EyeOn Baby Monitor (DCS-825L) 1.08.1 has multiple command injection vulnerabilities in the web service framework. An attacker can forge malicious HTTP requests to execute commands; authentication is required before executing the attack.

    Product
    Eyeon Baby Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 24, 2018D-Link EyeOn Baby Monitor (DCS-825L) 1.08.1 has a remote code execution vulnerability.CVE-2017-11563 · Other software · Dlink · reported by MITRECritical 9.8

    D-Link EyeOn Baby Monitor (DCS-825L) 1.08.1 has a remote code execution vulnerability. A UDP "Discover" service, which provides multiple functions such as changing the passwords and getting basic information, was installed on the device. A remote attacker can send a crafted UDP request to finderd to perform stack overflow and execute arbitrary code with root privilege on the device.

    Product
    Eyeon Baby Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 10, 2018Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded.CVE-2018-10626 · Other software · Medtronic · reported by ics-cert@hq.dhs.govMedium 4.4

    Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.

    Product
    24950 MyCareLink Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 10, 2018Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format.CVE-2018-10622 · Other software · Medtronic · reported by security@medtronic.comMedium 5.2

    Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.

    Product
    24950 MyCareLink Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 2, 2018Monitorix before 3.10.1 allows XSS via CGI variables.CVE-2018-7649 · Other software · Fibranet · reported by MITREMedium 6.1

    Monitorix before 3.10.1 allows XSS via CGI variables.

    Product
    Monitorix
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 25, 2018F5 BIG-IP 13.0.0-13.0.1, 12.1.0-12.1.3.6, or 11.2.1-11.6.3.2 HTTPS health monitors do not validate the identity of the monitored server.CVE-2018-5542 · Network & remote access · F5 Networks, Inc. · reported by f5sirt@f5.comHigh 8.1

    F5 BIG-IP 13.0.0-13.0.1, 12.1.0-12.1.3.6, or 11.2.1-11.6.3.2 HTTPS health monitors do not validate the identity of the monitored server.

    Product
    BIG-IP (LTM, AAM, AFM, Analytics, APM, ASM, DNS, Edge Gateway, FPS, GTM, Link Controller, PEM, WebAccelerator)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 18, 2018A vulnerability in the configuration and monitoring service of the Cisco SD-WAN Solution could allow an authenticated, local attacker to execute arbitrary code CVE-2018-0342 · Network & remote access · Cisco · reported by psirt@cisco.comMedium 6.7

    A vulnerability in the configuration and monitoring service of the Cisco SD-WAN Solution could allow an authenticated, local attacker to execute arbitrary code with root privileges or cause a denial of service (DoS) condition on an affected device. The vulnerability is due to incomplete bounds checks for data that is provided by the configuration and monitoring service of the affected solution. An attacker could exploit this vulnerability by sending malicious data to the vDaemon listening service on an affected device. A successful exploit could allow the attacker to cause a buffer overflow condition on the affected device, which could allow the attacker to execute arbitrary code with root privileges on the device or cause the vDaemon listening service to reload and result in a DoS condition on the device. This vulnerability affects the following Cisco products if they are running a release of the Cisco SD-WAN Solution prior to Release 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software, vSmart Controller Software. Cisco Bug ID

    Product
    Vbond Orchestrator
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 18, 2018Vulnerability in the JD Edwards EnterpriseOne Tools component of Oracle JD Edwards Products (subcomponent: Monitoring and Diagnostics).CVE-2018-2944 · Other software · Oracle Corporation · reported by secalert_us@oracle.comHigh 7.5

    Vulnerability in the JD Edwards EnterpriseOne Tools component of Oracle JD Edwards Products (subcomponent: Monitoring and Diagnostics). The supported version that is affected is 9.2. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise JD Edwards EnterpriseOne Tools. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all JD Edwards EnterpriseOne Tools accessible data. CVSS 3.0 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

    Product
    JD Edwards EnterpriseOne Tools
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 11, 2018While experiencing a broadcast storm, placing the fxp0 interface into promiscuous mode via the 'monitor traffic interface fxp0' can cause the system to crash anCVE-2018-0029 · Network & remote access · Juniper Networks · reported by sirt@juniper.netMedium 5.7

    While experiencing a broadcast storm, placing the fxp0 interface into promiscuous mode via the 'monitor traffic interface fxp0' can cause the system to crash and restart (vmcore). This issue only affects Junos OS 15.1 and later releases, and affects both single core and multi-core REs. Releases prior to Junos OS 15.1 are unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS: 15.1 versions prior to 15.1F6-S11, 15.1R4-S9, 15.1R6-S6, 15.1R7; 15.1X49 versions prior to 15.1X49-D140; 15.1X53 versions prior to 15.1X53-D59 on EX2300/EX3400; 15.1X53 versions prior to 15.1X53-D67 on QFX10K; 15.1X53 versions prior to 15.1X53-D233 on QFX5200/QFX5110; 15.1X53 versions prior to 15.1X53-D471, 15.1X53-D490 on NFX; 16.1 versions prior to 16.1R3-S8, 16.1R5-S4, 16.1R6-S1, 16.1R7; 16.2 versions prior to 16.2R1-S6, 16.2R2-S5, 16.2R3; 17.1 versions prior to 17.1R1-S7, 17.1R2-S7, 17.1R3; 17.2 versions prior to 17.2R1-S6, 17.2R2-S4, 17.2R3; 17.2X75 versions prior to 17.2X75-D90, 17.2X75-D110; 17.3 versions prior to 17.3R1-S4, 17.3R2; 17.4 versions prior to 17.4R1-S3, 17.4R2.

    Product
    Junos OS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 2, 2018Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password.CVE-2018-8870 · Other software · Medtronic · reported by ics-cert@hq.dhs.govMedium 6.4

    Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.

    Product
    24950 MyCareLink Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 2, 2018Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, iCVE-2018-8868 · Other software · Medtronic · reported by ics-cert@hq.dhs.govMedium 6.2

    Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.

    Product
    24950 MyCareLink Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 2, 2018Paessler PRTG Network Monitor OS Command Injection VulnerabilityCVE-2018-9276 · Other software · Paessler · reported by MITREExploitedHigh 7.2

    Paessler PRTG Network Monitor contains an OS command injection vulnerability that allows an attacker with administrative privileges to execute commands via the PRTG System Administrator web console.

    Product
    PRTG Network Monitor
    On CISA’s list since
    Feb 4, 2025 (federal fix deadline Feb 25, 2025)
    What to do
    Attackers are using this now. Install Paessler’s update today. If there is no update for your version, take the product off the internet or stop using it until there is.
  • Jun 18, 2018An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2.CVE-2018-12525 · Other software · Perfsonar · reported by MITREMedium 5.3

    An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2. A direct request to /images/ provides a directory listing.

    Product
    Monitoring And Debugging Dashboard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 18, 2018An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2.CVE-2018-12524 · Other software · Perfsonar · reported by MITREMedium 5.3

    An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2. A direct request to /lib/ provides a directory listing.

    Product
    Monitoring And Debugging Dashboard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 18, 2018An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2.CVE-2018-12523 · Other software · Perfsonar · reported by MITREMedium 5.3

    An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2. A direct request to /etc/ provides a directory listing.

    Product
    Monitoring And Debugging Dashboard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 18, 2018An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2.CVE-2018-12522 · Other software · Perfsonar · reported by MITREMedium 5.3

    An issue was discovered in perfSONAR Monitoring and Debugging Dashboard (MaDDash) 2.0.2. A direct request to /style/ provides a directory listing.

    Product
    Monitoring And Debugging Dashboard
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 14, 2018JavaMelody through 1.60.0 has XSS via the counter parameter in a clear_counter action to the /monitoring URI.CVE-2018-12432 · Other software · Javamelody Project · reported by MITREMedium 6.1

    JavaMelody through 1.60.0 has XSS via the counter parameter in a clear_counter action to the /monitoring URI.

    Product
    Javamelody
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 7, 2018A vulnerability in traffic-monitoring functions in Cisco Web Security Appliance (WSA) could allow an unauthenticated, remote attacker to circumvent Layer 4 TrafCVE-2018-0353 · Network & remote access · Cisco · reported by psirt@cisco.comHigh 7.5

    A vulnerability in traffic-monitoring functions in Cisco Web Security Appliance (WSA) could allow an unauthenticated, remote attacker to circumvent Layer 4 Traffic Monitor (L4TM) functionality and bypass security protections. The vulnerability is due to a change in the underlying operating system software that is responsible for monitoring affected traffic. An attacker could exploit this vulnerability by sending crafted IP packets to an affected device. A successful exploit could allow the attacker to pass traffic through the device, which the WSA was configured to deny. This vulnerability affects both IPv4 and IPv6 traffic. This vulnerability affects Cisco AsyncOS versions for WSA on both virtual and hardware appliances running any release of the 10.5.1, 10.5.2, or 11.0.0 WSA Software. The WSA is vulnerable if it is configured for L4TM. Cisco Bug IDs: CSCvg78875.

    Product
    Web Security Appliance
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 5, 2018IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100CVE-2018-10601 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 8.2

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.

    Product
    IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 5, 2018IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100CVE-2018-10599 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govMedium 5.3

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.

    Product
    IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 5, 2018IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100CVE-2018-10597 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 8.3

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.

    Product
    IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 4, 2018healthcenter - IBM Monitoring and Diagnostic Tools health Center agent healthcenter downloads binary resources over HTTP, which leaves it vulnerable to MITM attCVE-2016-10684 · Other software · HackerOne · reported by support@hackerone.comHigh 8.1

    healthcenter - IBM Monitoring and Diagnostic Tools health Center agent healthcenter downloads binary resources over HTTP, which leaves it vulnerable to MITM attacks. It may be possible to cause remote code execution (RCE) by swapping out the requested resources with an attacker controlled copy if the attacker is on the network or positioned in between the user and the remote server.

    Product
    healthcenter node module
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 29, 2018product-monitor is a HTML/JavaScript template for monitoring a product by encouraging product developers to gather all the information about the status of a proCVE-2016-10567 · Other software · HackerOne · reported by support@hackerone.comHigh 8.1

    product-monitor is a HTML/JavaScript template for monitoring a product by encouraging product developers to gather all the information about the status of a product, including live monitoring, statistics, endpoints, and test results into one place. product-monitor versions below 2.2.5 download JavaScript resources over HTTP, which leaves the module vulnerable to MITM attacks. It may be possible to cause remote code execution (RCE) by swapping out the requested JavaScript file with an attacker controlled JavaScript file if the attacker is on the network or positioned in between the user and the remote server.

    Product
    product-monitor node module
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 15, 2018In Jenkins before versions 2.44, 2.32.2 low privilege users were able to act on administrative monitors due to them not being consistently protected by permissiCVE-2017-2604 · Other software · [UNKNOWN] · reported by Red HatMedium 4.3

    In Jenkins before versions 2.44, 2.32.2 low privilege users were able to act on administrative monitors due to them not being consistently protected by permission checks (SECURITY-371).

    Product
    jenkins
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 15, 2018In jenkins before versions 2.44, 2.32.2 node monitor data could be viewed by low privilege users via the remote API.CVE-2017-2600 · Other software · [UNKNOWN] · reported by Red HatMedium 4.3

    In jenkins before versions 2.44, 2.32.2 node monitor data could be viewed by low privilege users via the remote API. These included system configuration and runtime information of these nodes (SECURITY-343).

    Product
    jenkins
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2018IBM Security Guardium 10.0, 10.0.1, and 10.1 through 10.1.4 Database Activity Monitor does not require that users should have strong passwords by default, whichCVE-2017-1601 · Other software · IBM · reported by psirt@us.ibm.comCritical 9.8

    IBM Security Guardium 10.0, 10.0.1, and 10.1 through 10.1.4 Database Activity Monitor does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 132624.

    Product
    Security Guardium Database Activity Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 30, 2018Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can neceCVE-2017-9658 · Other software · Philips · reported by ics-cert@hq.dhs.govMedium 6.5

    Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

    Product
    IntelliVue MX40 Patient Worn Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 30, 2018Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring stationCVE-2017-9657 · Other software · Philips · reported by ics-cert@hq.dhs.govMedium 6.5

    Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.

    Product
    IntelliVue MX40 Patient Worn Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 20, 2018Paessler PRTG Network Monitor before 18.1.39.1648 mishandles stack memory during unspecified API calls.CVE-2018-10253 · Other software · Paessler · reported by MITREHigh 7.5

    Paessler PRTG Network Monitor before 18.1.39.1648 mishandles stack memory during unspecified API calls.

    Product
    Prtg Network Monitor
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 20, 2018An issue was discovered in NcMonitorServer.exe in NC Monitor Server in NComputing vSpace Pro 10 and 11.CVE-2018-10201 · Other software · Ncomputing · reported by MITREHigh 7.5

    An issue was discovered in NcMonitorServer.exe in NC Monitor Server in NComputing vSpace Pro 10 and 11. It is possible to read arbitrary files outside the root directory of the web server. This vulnerability could be exploited remotely by a crafted URL without credentials, with .../ or ...\ or ..../ or ....\ as a directory-traversal pattern to TCP port 8667.

    Product
    Vspace Pro
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.