Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 36 min ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
35added in the last 30 days
575new WordPress flaws this week
391,358entries in the database

1,389 results · page 27 of 28

  • Dec 15, 2015Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitraryCVE-2015-7918 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.8

    Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.

    Product
    Proclima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 14, 2015Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary codeCVE-2015-3977 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.7

    Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.

    Product
    Imt25 Magnetic Flow DTM
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 5, 2015The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via aCVE-2015-3938 · Other software · Mitsubishi Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter.

    Product
    Melsec Fx3g
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 25, 2015Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code or cause a denial of service (unhandled runtime exception anCVE-2015-7375 · Other software · Indusoft · reported by MITREHigh 7.5

    Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code or cause a denial of service (unhandled runtime exception and application crash) via a crafted Indusoft Project file.

    Product
    Web Studio
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 25, 2015The Remote Agent component in Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code via unspecified vectors, aka ZCVE-2015-7374 · Other software · Indusoft · reported by MITREHigh 7.5

    The Remote Agent component in Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code via unspecified vectors, aka ZDI-CAN-2649.

    Product
    Web Studio
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 18, 2015Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discCVE-2015-3962 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 5

    Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.

    Product
    Struxureware Building Expert Multi-purpose Management
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 3, 2015Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan CVE-2015-3940 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.9

    Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.

    Product
    Wonderware System Platform 2014
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 31, 2015Schneider Electric InduSoft Web Studio before 7.1.3.5 Patch 5 and Wonderware InTouch Machine Edition through 7.1 SP3 Patch 4 use cleartext for project-window paCVE-2015-1009 · Other software · Indusoft · reported by ics-cert@hq.dhs.govLow 1.7

    Schneider Electric InduSoft Web Studio before 7.1.3.5 Patch 5 and Wonderware InTouch Machine Edition through 7.1 SP3 Patch 4 use cleartext for project-window password storage, which allows local users to obtain sensitive information by reading a file.

    Product
    Web Studio
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 5, 2015Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before CVE-2014-9201 · Other software · Beckwithelectric · reported by ics-cert@hq.dhs.govMedium 6.4

    Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank Control with firmware before D-0346V03.00.02, M-6280A Digital Capacitor Bank Control with firmware before D-0254V03.05.05, and M-6280 Digital Capacitor Bank Control do not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.

    Product
    M-2001d Digital Tapchanger Control
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2015Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFCVE-2014-8390 · Other software · Schneider-electric · reported by MITREMedium 4.4

    Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.

    Product
    Vampset
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 29, 2015Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentiaCVE-2015-0999 · Other software · Aveva · reported by ics-cert@hq.dhs.govLow 2.1

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.

    Product
    Aveva Edge
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 29, 2015Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, whCVE-2015-0998 · Other software · Aveva · reported by ics-cert@hq.dhs.govLow 3.3

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.

    Product
    Aveva Edge
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 29, 2015Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface thatCVE-2015-0997 · Other software · Aveva · reported by ics-cert@hq.dhs.govMedium 5

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.

    Product
    Aveva Edge
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 29, 2015Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext passCVE-2015-0996 · Other software · Aveva · reported by ics-cert@hq.dhs.govLow 2.1

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.

    Product
    Aveva Edge
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 13, 2015Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectorsCVE-2015-0982 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.5

    Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.

    Product
    Pelco Ds-nv
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 13, 2015Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 alloCVE-2014-9206 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.9

    Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.

    Product
    Device Type Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 1, 2015Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus CommunicCVE-2014-9200 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 7.5

    Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.

    Product
    Unity Pro
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2015The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for rCVE-2014-9198 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10

    The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.

    Product
    ETG3000 FactoryCast HMI Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2015The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, whichCVE-2014-9197 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10

    The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

    Product
    ETG3000 FactoryCast HMI Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 9, 2015Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via CVE-2014-9190 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10

    Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.

    Product
    InTouch Access Anywhere Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-9188 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.

    Product
    ProClima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-8514 · Other software · Schneider Electric · reported by MITREHigh 7.5

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.

    Product
    Proclima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-8513 · Other software · Schneider Electric · reported by MITREHigh 7.5

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.

    Product
    Proclima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 27, 2014Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiedCVE-2014-8512 · Other software · Schneider Electric · reported by MITREHigh 7.5

    Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.

    Product
    Proclima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 27, 2014Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiedCVE-2014-8511 · Other software · Schneider-electric · reported by MITREHigh 10

    Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.

    Product
    Proclima
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 6, 2014XML external entity (XXE) vulnerability in the WebHMI server in Yokogawa Electric Corporation FAST/TOOLS before R9.05-SP2 allows local users to cause a denial oCVE-2014-7251 · Other software · Yokogawa · reported by vultures@jpcert.or.jpLow 3.2

    XML external entity (XXE) vulnerability in the WebHMI server in Yokogawa Electric Corporation FAST/TOOLS before R9.05-SP2 allows local users to cause a denial of service (CPU or network traffic consumption) or read arbitrary files via unspecified vectors.

    Product
    Fast/tools
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 24, 2014Electric Cloud ElectricCommander before 4.2.6 and 5.x before 5.0.3 uses world-writable permissions for (1) eccert.pl and (2) ecconfigure.pl, which allows local CVE-2014-7180 · Other software · Electric Cloud · reported by MITREMedium 4.6

    Electric Cloud ElectricCommander before 4.2.6 and 5.x before 5.0.3 uses world-writable permissions for (1) eccert.pl and (2) ecconfigure.pl, which allows local users to execute arbitrary Perl code by modifying these files.

    Product
    Electriccommander
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 19, 2014The HEA Mobile (aka com.homerelectric.smartapps) application 1.153.0034 for Android does not verify X.509 certificates from SSL servers, which allows man-in-theCVE-2014-7422 · Other software · Homerelectric · reported by cret@cert.orgMedium 5.4

    The HEA Mobile (aka com.homerelectric.smartapps) application 1.153.0034 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    HEA Mobile
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 3, 2014Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NCVE-2014-0754 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10

    Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request.

    Product
    Ethernet modules for M340, Quantum and Premium PLC ranges
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 30, 2014The SED Account (aka com.starkville.smartapps) application 1.153.0034 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-mCVE-2014-6850 · Other software · Starkvilleelectric · reported by cret@cert.orgMedium 5.4

    The SED Account (aka com.starkville.smartapps) application 1.153.0034 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    SED Account
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 23, 2014The Open Electrical Webser (aka com.wOpenElectricalWeb) application 0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-theCVE-2014-6683 · Other software · Openelectrical · reported by cret@cert.orgMedium 5.4

    The Open Electrical Webser (aka com.wOpenElectricalWeb) application 0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    Open Electrical Webser
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 18, 2014Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remotCVE-2014-5413 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.4

    Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.

    Product
    ClearSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 18, 2014Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the gueCVE-2014-5412 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.4

    Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.

    Product
    ClearSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 18, 2014Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticateCVE-2014-5411 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 4.9

    Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.

    Product
    ClearSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 15, 2014Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a CVE-2014-5407 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 4.1

    Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.

    Product
    VAMPSET
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 9, 2014The Dubstep Hero (aka com.electricpunch.dubstephero) application 1.9 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-miCVE-2014-5848 · Other software · Iqnect · reported by cret@cert.orgMedium 5.4

    The Dubstep Hero (aka com.electricpunch.dubstephero) application 1.9 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    Dubstep Hero
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2014SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQCVE-2014-5399 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 7.5

    SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

    Product
    Wonderware Information Server Portal
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2014Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to read arbitrary files or cause a denial of service vCVE-2014-5398 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govLow 2.1

    Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to read arbitrary files or cause a denial of service via an XML external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.

    Product
    Wonderware Information Server Portal
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2014Cross-site scripting (XSS) vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to inject CVE-2014-5397 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 7.5

    Cross-site scripting (XSS) vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

    Product
    Wonderware Information Server Portal
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2014Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive informationCVE-2014-2381 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govLow 2.1

    Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file.

    Product
    Wonderware Information Server Portal
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 27, 2014Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive informCVE-2014-2380 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file.

    Product
    Wonderware Information Server Portal
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 4, 2014Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TCVE-2014-0789 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 5

    Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a denial of service via long arguments to unspecified functions.

    Product
    OPC Factory Server (OFS)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2014Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary cCVE-2013-0662 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 9.3

    Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.

    Product
    Concept
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 14, 2014The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 RCVE-2014-0779 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.8

    The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file).

    Product
    ClearSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 28, 2014Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.3CVE-2014-0774 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.8

    Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.

    Product
    TLXCDSUOFS33
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 28, 2014Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a TrojanCVE-2014-0759 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 5.9

    Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character.

    Product
    Floating License Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 26, 2014Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA ExpCVE-2013-2824 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.8

    Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.

    Product
    Citectscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 23, 2014An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs viaCVE-2013-2817 · Other software · Mitsubishielectric · reported by ics-cert@hq.dhs.govHigh 9.3

    An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click.

    Product
    Mc-worx Suite
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 31, 2014The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (tempoCVE-2013-6143 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 5

    The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.

    Product
    Telvent Sage 3030 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 15, 2014DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remoteCVE-2013-6142 · Other software · Aveva · reported by ics-cert@hq.dhs.govMedium 4.3

    DNP3Driver.exe in the DNP3 driver in Schneider Electric ClearSCADA 2010 R2 through 2010 R3.1 and SCADA Expert ClearSCADA 2013 R1 through 2013 R1.2 allows remote attackers to cause a denial of service (resource consumption) via IP packets containing errors that trigger event-journal messages.

    Product
    Clearscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.