Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 2 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
35added in the last 30 days
575new WordPress flaws this week
391,358entries in the database

1,389 results · page 24 of 28

  • Aug 29, 2018An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0).CVE-2018-7790 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.

    Product
    Modicon M221, all references, all versions prior to firmware V1.6.2.0
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 29, 2018A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product.CVE-2018-7795 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 5.4

    A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.

    Product
    PowerLogic - PM5560 prior to FW version 2.5.4
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 29, 2018An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior toCVE-2018-7789 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.5

    An Improper Check for Unusual or Exceptional Conditions vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to remotely reboot Modicon M221 using crafted programing protocol frames.

    Product
    Modicon M221, all references, all versions prior to firmware V1.6.2.0
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTPCVE-2018-7787 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 5.3

    In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request.

    Product
    U.motion Builder
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicCVE-2018-7786 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 6.1

    In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.

    Product
    U.motion Builder
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.CVE-2018-7785 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    In Schneider Electric U.motion Builder software versions prior to v1.3.4, a remote command injection allows authentication bypass.

    Product
    U.motion Builder
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a commaCVE-2018-7784 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    In Schneider Electric U.motion Builder software versions prior to v1.3.4, this exploit occurs when the submitted data of an input string is evaluated as a command by the application. In this way, the attacker could execute code, read the stack, or cause a segmentation fault in the running application.

    Product
    U.motion Builder
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resultinCVE-2018-7783 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.5

    Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file.

    Product
    SoMachine Basic
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear tCVE-2018-7782 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, authenticated users can view passwords in clear text.

    Product
    Pelco Sarix Professional V1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authentCVE-2018-7781 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.

    Product
    Pelco Sarix Professional V1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi progCVE-2018-7780 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".

    Product
    Pelco Sarix Professional V1
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an CVE-2018-7779 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.5

    In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access.

    Product
    Wiser for KNX
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administraCVE-2018-7778 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

    Product
    Evlink Charging Station
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versionsCVE-2018-7777 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7776 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 4.3

    The vulnerability exists within error.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. System information is returned to the attacker that contains sensitive data.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7774 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of localize.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the username input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7773 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of nfcserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the sessionid input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.CVE-2018-7772 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of applets which are exposed on the web service in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query to determine whether a user is logged in is subject to SQL injection on the loginSeed parameter, which can be embedded in the HTTP cookie of the request.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7771 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8

    The vulnerability exists within processing of editscript.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A directory traversal vulnerability allows a caller with standard user privileges to write arbitrary php files anywhere in the web service directory tree.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7770 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 6.5

    The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7769 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of xmlserver.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7768 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of loadtemplate.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the tpl input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7767 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7766 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of track_getdata.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the id input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7765 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7764 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 4.3

    The vulnerability exists within runscript.php applet in Schneider Electric U.motion Builder software versions prior to v1.3.4. There is a directory traversal vulnerability in the processing of the 's' parameter of the applet.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 3, 2018The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4.CVE-2018-7763 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 4.3

    The vulnerability exists within css.inc.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The 'css' parameter contains a directory traversal vulnerability.

    Product
    U.Motion
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2018Northern Electric & Power (NEP) inverter devices allow remote attackers to obtain potentially sensitive information via a direct request for the nep/status/indeCVE-2018-12927 · Other software · Northernnep · reported by MITREHigh 7.5

    Northern Electric & Power (NEP) inverter devices allow remote attackers to obtain potentially sensitive information via a direct request for the nep/status/index/1 URI.

    Product
    Northern Electric & Power Inverter Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 25, 2018SAJ Solar Inverter allows remote attackers to obtain potentially sensitive information via a direct request for the inverter_info.htm or english_main.htm URI.CVE-2018-12735 · Other software · Saj-electric · reported by MITREHigh 7.5

    SAJ Solar Inverter allows remote attackers to obtain potentially sensitive information via a direct request for the inverter_info.htm or english_main.htm URI.

    Product
    SAJ Solar Inverter
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2018Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases.CVE-2017-9637 · Other software · Schneider Electric SE · reported by ics-cert@hq.dhs.govMedium 4.1

    Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

    Product
    Ampla MES
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2018Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges.CVE-2017-9635 · Other software · Schneider Electric SE · reported by ics-cert@hq.dhs.govLow 3.9

    Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

    Product
    Ampla MES
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 14, 2018In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 7CVE-2017-6021 · Other software · Schneider Electric SE · reported by ics-cert@hq.dhs.govHigh 7.5

    In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

    Product
    ClearSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 4, 2018In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program areCVE-2018-8872 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 8.1

    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.

    Product
    Triconex Tricon
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 4, 2018In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location.CVE-2018-7522 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.7

    In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.

    Product
    Triconex Tricon
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versiCVE-2018-8840 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govCritical 9.8

    A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.

    Product
    Schneider Electric InduSoft Web Studio and InTouch Machine Edition
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 whichCVE-2018-7762 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.5

    A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.

    Product
    Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitCVE-2018-7761 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.

    Product
    Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0202
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.CVE-2018-7760 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.

    Product
    Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0201
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.CVE-2018-7759 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.5

    A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.

    Product
    Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0200
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy EtheCVE-2018-7758 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 6.5

    A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number.

    Product
    MiCOM P540D Range with Legacy Ethernet Board
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPSCVE-2018-7246 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartext

    Product
    66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS.CVE-2018-7245 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.1

    An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization.

    Product
    66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS.CVE-2018-7244 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 5.3

    An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.

    Product
    66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS.CVE-2018-7243 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.

    Product
    66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the commCVE-2018-7242 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.

    Product
    Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communicatioCVE-2018-7241 · Other software · Schneider Electric SE · reported by cybersecurity@se.comCritical 9.8

    Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.

    Product
    Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR0200
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 18, 2018A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution.CVE-2018-7240 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8

    A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.

    Product
    Modicon Quantum
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 17, 2018Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack.CVE-2017-9638 · Other software · Mitsubishi Electric Europe B.V. · reported by ics-cert@hq.dhs.govCritical 9.8

    Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

    Product
    E-Designer
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 17, 2018Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap.CVE-2017-9636 · Other software · Mitsubishi Electric Europe B.V. · reported by ics-cert@hq.dhs.govCritical 9.8

    Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

    Product
    E-Designer
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 17, 2018Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations.CVE-2017-9634 · Other software · Mitsubishi Electric Europe B.V. · reported by ics-cert@hq.dhs.govCritical 9.8

    Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.

    Product
    E-Designer
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.