Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
62 results · page 2 of 2
Jul 22, 2017When ImageMagick 7.0.6-1 processes a crafted file in convert, it can lead to a heap-based buffer over-read in the WriteUILImage() function in coders/uil.c.CVE-2017-11533 · Other software · Imagemagick · reported by MITREMedium 6.5
When ImageMagick 7.0.6-1 processes a crafted file in convert, it can lead to a heap-based buffer over-read in the WriteUILImage() function in coders/uil.c.
- Product
- Imagemagick
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordgithub.comusn.ubuntu.com
Dec 15, 2015The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of sCVE-2015-8561 · Other software · Schneider-electric · reported by MITREMedium 6.8
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comzerodayinitiative.com
Dec 15, 2015Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitraryCVE-2015-7918 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.8
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comzerodayinitiative.com
Jun 28, 2015Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows rCVE-2015-4174 · Other software · Siemens · reported by MITREMedium 4.3
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
- Product
- Climatix Bacnet/ip
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comsecurityfocus.com
Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-9188 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govHigh 10
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
- Product
- ProClima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comcisa.gov
Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-8514 · Other software · Schneider Electric · reported by MITREHigh 7.5
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Dec 27, 2014Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiCVE-2014-8513 · Other software · Schneider Electric · reported by MITREHigh 7.5
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comics-cert.us-cert.gov
Dec 27, 2014Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiedCVE-2014-8512 · Other software · Schneider Electric · reported by MITREHigh 7.5
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comics-cert.us-cert.gov
Dec 27, 2014Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecifiedCVE-2014-8511 · Other software · Schneider-electric · reported by MITREHigh 10
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comics-cert.us-cert.gov
Oct 20, 2009Multiple integer overflows in tiffread.c in CamlImages 2.2 might allow remote attackers to execute arbitrary code via TIFF images containing large width and heiCVE-2009-3296 · Other software · Gallium.inria · reported by MITREHigh 7.5
Multiple integer overflows in tiffread.c in CamlImages 2.2 might allow remote attackers to execute arbitrary code via TIFF images containing large width and height values that trigger heap-based buffer overflows.
- Product
- Camimages
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecunia.comsecurity.debian.org
Aug 4, 2009Multiple integer overflows in CamlImages 2.2 might allow context-dependent attackers to execute arbitrary code via images containing large width and height valuCVE-2009-2660 · Other software · JUN Furuse · reported by MITREMedium 6.8
Multiple integer overflows in CamlImages 2.2 might allow context-dependent attackers to execute arbitrary code via images containing large width and height values that trigger a heap-based buffer overflow, related to (1) crafted GIF files (gifread.c) and (2) crafted JPEG files (jpegread.c), a different vulnerability than CVE-2009-2295.
- Product
- Camlimages
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordftp.debian.orgftp.debian.org
Jul 5, 2009Multiple integer overflows in CamlImages 2.2 and earlier might allow context-dependent attackers to execute arbitrary code via a crafted PNG image with large wiCVE-2009-2295 · Other software · JUN Furuse · reported by MITREHigh 7.5
Multiple integer overflows in CamlImages 2.2 and earlier might allow context-dependent attackers to execute arbitrary code via a crafted PNG image with large width and height values that trigger a heap-based buffer overflow in the (1) read_png_file or (2) read_png_file_as_rgb24 function.
- Product
- Camlimages
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.