Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
66 results · page 2 of 2
May 5, 2022RTI Connext DDS Professional and Connext DDS Secure Versions 4.2x to 6.1.0 vulnerable to a stack-based buffer overflow, which may allow a local attacker to execCVE-2021-38433 · Other software · RTI · reported by ics-cert@hq.dhs.govMedium 6.6
RTI Connext DDS Professional and Connext DDS Secure Versions 4.2x to 6.1.0 vulnerable to a stack-based buffer overflow, which may allow a local attacker to execute arbitrary code.
- Product
- Connext DDS Professional
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.rti.comcisa.gov
May 5, 2022RTI Connext DDS Professional and Connext DDS Secure Versions 4.2.x to 6.1.0 are vulnerable to a stack-based buffer overflow, which may allow a local attacker toCVE-2021-38427 · Other software · RTI · reported by ics-cert@hq.dhs.govMedium 6.6
RTI Connext DDS Professional and Connext DDS Secure Versions 4.2.x to 6.1.0 are vulnerable to a stack-based buffer overflow, which may allow a local attacker to execute arbitrary code.
- Product
- Connext DDS Professional
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsupport.rti.comcisa.gov
Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmwarCVE-2021-30066 · Other software · Belden · reported by MITREMedium 6.8
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packeCVE-2021-30065 · Other software · Belden · reported by MITREHigh 7.5
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can sucCVE-2021-30064 · Other software · Belden · reported by MITRECritical 9.8
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Apr 3, 2022On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer CVE-2021-30063 · Other software · Belden · reported by MITREHigh 7.5
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Apr 3, 2022On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforceCVE-2021-30062 · Other software · Belden · reported by MITREHigh 7.5
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximateCVE-2021-30061 · Other software · Belden · reported by MITREMedium 6.8
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.
- Product
- Tofino Xenon Security Appliance Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.combelden.com
Feb 11, 2022A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially craCVE-2021-22801 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8
A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)
- Product
- Connexium Network Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comdownload.schneider-electric.com
Jun 11, 2021The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device managemCVE-2021-27410 · Other software · Hillrom · reported by ics-cert@hq.dhs.govCritical 9.8
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
- Product
- Connex Central Station
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.cisa.govus-cert.cisa.gov
Jun 11, 2021The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-boCVE-2021-27408 · Other software · Hillrom · reported by ics-cert@hq.dhs.govHigh 7.5
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
- Product
- Connex Central Station
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordus-cert.cisa.govus-cert.cisa.gov
Jul 31, 2017MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access.CVE-2017-11743 · Other software · Medhost · reported by MITRECritical 9.8
MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts.
- Product
- Connex
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordseclists.orgsecurityfocus.com
Jul 25, 2017MEDHOST Connex contains hard-coded credentials that are used for customer database access.CVE-2017-11614 · Other software · Medhost · reported by MITRECritical 9.8
MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account.
- Product
- Connex
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordseclists.orgseclists.org
Feb 13, 2017An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFECCVE-2016-8352 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 10
An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.
- Product
- Connexium Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Mar 19, 2009PHP remote file inclusion vulnerability in connexion.php in PHPGKit 0.9 allows remote attackers to execute arbitrary PHP code via a URL in the DOCUMENT_ROOT parCVE-2008-6491 · Other software · Denis Moinel · reported by MITREHigh 7.5
PHP remote file inclusion vulnerability in connexion.php in PHPGKit 0.9 allows remote attackers to execute arbitrary PHP code via a URL in the DOCUMENT_ROOT parameter. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
- Product
- Phpgkit
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecurityfocus.com
Mar 2, 2007SQL injection vulnerability in connexion.php in Ban 0.1 allows remote attackers to execute arbitrary SQL commands via the id parameter.CVE-2006-7089 · Other software · BAN · reported by MITREHigh 7.5
SQL injection vulnerability in connexion.php in Ban 0.1 allows remote attackers to execute arbitrary SQL commands via the id parameter.
- Product
- BAN
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordmarc.infoexchange.xforce.ibmcloud.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.