Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
36added in the last 30 days
584new WordPress flaws this week
391,288entries in the database

1,389 results · page 13 of 28

  • Apr 14, 2022Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP SmallCVE-2022-26034 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpCritical 9.1

    Improper authentication vulnerability in the communication protocol provided by AD (Automation Design) server of CENTUM VP R6.01.10 to R6.09.00, CENTUM VP Small R6.01.10 to R6.09.00, CENTUM VP Basic R6.01.10 to R6.09.00, and B/M9000 VP R8.01.01 to R8.03.01 allows an attacker to use the functions provided by AD server. This may lead to leakage or tampering of data managed by AD server.

    Product
    CENTUM VP series with VP6E5000(AD Suite Engineering ServerFunction) installed and B/M9000 VP
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2022A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solutCVE-2022-0221 · Other software · Schneider Electric · reported by cybersecurity@se.comMedium 5.5

    A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a remote system controlled by an attacker. Affected Product: SCADAPack Workbench (6.6.8a and prior)

    Product
    SCADAPack Workbench
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2022A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed inCVE-2021-22797 · Other software · Schneider Electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)

    Product
    EcoStruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2022A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution CVE-2021-22795 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

    Product
    StruxureWare Data Center Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2022A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution.CVE-2021-22794 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

    Product
    StruxureWare Data Center Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2022A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM priCVE-2019-6834 · Other software · Schneider Electric · reported by cybersecurity@se.comHigh 7.3

    A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0)

    Product
    Software Update (SESU) – SUT Service component
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022The affected product is vulnerable to an out-of-bounds read, which may result in code executionCVE-2022-24383 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    The affected product is vulnerable to an out-of-bounds read, which may result in code execution

    Product
    Alpha5
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.CVE-2022-21228 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.

    Product
    Alpha5
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.CVE-2022-21214 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution.

    Product
    Alpha5
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.CVE-2022-21202 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govLow 3.3

    The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information.

    Product
    Alpha5
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.CVE-2022-21168 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govLow 3.3

    The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure.

    Product
    Alpha5
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging.CVE-2022-0878 · Other software · Combined Charging System · reported by vulnerability@ncsc.chMedium 4.6

    Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging. To exchange important messages such as the State of Charge (SoC) with the Electric Vehicle Supply Equipment (EVSE) CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY (HPGP) power-line communication (PLC) technology. The attack interrupts necessary control communication between the vehicle and charger, causing charging sessions to abort. The attack can be conducted wirelessly from a distance using electromagnetic interference, allowing individual vehicles or entire fleets to be disrupted simultaneously. In addition, the attack can be mounted with off-the-shelf radio hardware and minimal technical knowledge. With a power budget of 1 W, the attack is successful from around 47 m distance. The exploited behavior is a required part of the HomePlug Green PHY, DIN 70121 & ISO 15118 standards and all known implementations exhibit it. In addition to electric cars, Brokenwire affects electric ships, airplanes and heavy duty vehicles utilising these standards.

    Product
    Combined Charging System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmwarCVE-2021-30066 · Other software · Belden · reported by MITREMedium 6.8

    On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verification (for a USB stick) can be bypassed. NOTE: this issue exists because of an incomplete fix of CVE-2017-11400.

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packeCVE-2021-30065 · Other software · Belden · reported by MITREHigh 7.5

    On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer. NOTE: this issue exists because of an incomplete fix of CVE-2017-11401.

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can sucCVE-2021-30064 · Other software · Belden · reported by MITRECritical 9.8

    On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state).

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer CVE-2021-30063 · Other software · Belden · reported by MITREHigh 7.5

    On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforceCVE-2021-30062 · Other software · Belden · reported by MITREHigh 7.5

    On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforcer.

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 3, 2022On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximateCVE-2021-30061 · Other software · Belden · reported by MITREMedium 6.8

    On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, physically proximate attackers can execute code via a crafted file on a USB stick.

    Product
    Tofino Xenon Security Appliance Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F serCVE-2022-25160 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpMedium 5.9

    Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previously eaves

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F seriesCVE-2022-25159 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 8.1

    Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions and Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions allows a remote unauthenticated attacker to login to the product by replay attack.

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F serCVE-2022-25158 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpCritical 9.1

    Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ7

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi ElectriCVE-2022-25157 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpCritical 9.1

    Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R16/32/64MTCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GF11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GP21(S)-SX all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELS

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versionsCVE-2022-25156 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 8.1

    Use of Weak Hash vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELSEC Q series QJ71C24N(-R2/R4) all versions, Mitsubishi Electric MELSEC Q series QJ71E71-100 all versions, Mitsubishi Electric MELSEC Q series QJ72BR15 all versions, Mitsubishi

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2022Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi ElectriCVE-2022-25155 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 8.1

    Use of Password Hash Instead of Password for Authentication vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric MELSEC iQ-R series R04/08/16/32/120(EN)CPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120SFCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PCPU all versions, Mitsubishi Electric MELSEC iQ-R series R08/16/32/120PSFCPU all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-T2 all versions, Mitsubishi Electric MELSEC iQ-R series RJ71GN11-EIP all versions, Mitsubishi Electric MELSEC iQ-R series RJ71C24(-R2/R4) all versions, Mitsubishi Electric MELSEC iQ-R series RJ71EN71 all versions, Mitsubishi Electric MELSEC iQ-R series RJ72GF15-T2 all versions, Mitsubishi Electric MELSEC Q series Q03UDECPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/10/13/20/26/50/100UDEHCPU all versions, Mitsubishi Electric MELSEC Q series Q03/04/06/13/26UDVCPU all versions, Mitsubishi Electric MELSEC Q series Q04/06/13/26UDPVCPU all versions, Mitsubishi Electric MELS

    Product
    Fx5uc Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.CVE-2022-23402 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpCritical 9.8

    The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00

    Product
    CENTUM VP
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022The following Yokogawa Electric products contain insecure DLL loading issues.CVE-2022-23401 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8

    The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets.CVE-2022-22729 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.8

    CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 toCVE-2022-22151 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1

    CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration.CVE-2022-22148 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8

    'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption.CVE-2022-22145 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1

    CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration.CVE-2022-22141 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8

    'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09CVE-2022-21808 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.8

    Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5CVE-2022-21194 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpCritical 9.8

    The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM VP
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2022There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 CVE-2022-21177 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1

    There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.

    Product
    CENTUM CS 3000
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controllCVE-2022-24323 · Other software · Schneider Electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)

    Product
    EcoStruxure Process Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between tCVE-2022-24322 · Other software · Schneider Electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

    Product
    EcoStruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door.CVE-2021-22783 · Other software · Schneider Electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door (All versions)

    Product
    Ritto Wiser Door
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection isCVE-2022-22806 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

    Product
    SmartConnect
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperlyCVE-2022-22805 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

    Product
    SmartConnect
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 9, 2022A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and usedCVE-2022-0715 · Other software · Schneider Electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series (SMT Series ID=18: UPS 09.8 and prior / SMT Series ID=1040: UPS 01.2 and prior / SMT Series ID=1031: UPS 03.1 and prior), SMC Series (SMC Series ID=1005: UPS 14.1 and prior / SMC Series ID=1007: UPS 11.0 and prior / SMC Series ID=1041: UPS 01.1 and prior), SCL Series (SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior), SMX Series (SMX Series ID=20: UPS 10.2 and prior / SMX Series ID=23: UPS 07.0 and prior), SRT Series (SRT Series ID=1010/1019/1025: UPS 08.3 and prior / SRT Series ID=1024: UPS 01.0 and prior / SRT Series ID=1020: UPS 10.4 and prior / SRT Series ID=1021: UPS 12.2 and prior / SRT Series ID=1001/1013: UPS 05.1 and prior / SRT Series ID=1002/1014: UPSa05.2 and prior), APC SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior /

    Product
    APC Smart-UPS
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 25, 2022Exploitation of this vulnerability may result in local privilege escalation and code execution.CVE-2022-23921 · Other software · General Electric · reported by ics-cert@hq.dhs.govHigh 7.5

    Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.

    Product
    Proficy CIMPLICITY
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 25, 2022The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in tCVE-2022-21798 · Other software · General Electric · reported by ics-cert@hq.dhs.govHigh 7.5

    The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.

    Product
    Proficy CIMPLICITY
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied CVE-2021-22824 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSCVE-2021-22823 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a maliciouCVE-2021-22806 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSCVE-2021-22805 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.1

    A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the contCVE-2021-22804 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attaCVE-2021-22803 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user suppliCVE-2021-22802 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)

    Product
    Interactive Graphical Scada System Data Collector
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially craCVE-2021-22801 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)

    Product
    Connexium Network Manager
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.