Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 51 min ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
36added in the last 30 days
584new WordPress flaws this week
391,288entries in the database

850 results · page 13 of 17

  • Nov 9, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-39307 · Other software · grafana · reported by GitHubMedium 6.7

    Grafana is an open-source platform for monitoring and observability. When using the forget password on the login page, a POST request is made to the `/api/user/password/sent-reset-email` URL. When the username or email does not exist, a JSON response contains a “user not found” message. This leaks information to unauthenticated users and introduces a security risk. This issue has been patched in 9.2.4 and backported to 8.5.15. There are no known workarounds.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 9, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-39306 · Other software · grafana · reported by GitHubMedium 6.4

    Grafana is an open-source platform for monitoring and observability. Versions prior to 9.2.4, or 8.5.15 on the 8.X branch, are subject to Improper Input Validation. Grafana admins can invite other members to the organization they are an admin for. When admins add members to the organization, non existing users get an email invite, existing members are added directly to the organization. When an invite link is sent, it allows users to sign up with whatever username/email address the user chooses and become a member of the organization. This introduces a vulnerability which can be used with malicious intent. This issue is patched in version 9.2.4, and has been backported to 8.5.15. There are no known workarounds.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 8, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-39328 · Other software · grafana · reported by GitHubCritical 9.8

    Grafana is an open-source platform for monitoring and observability. Versions starting with 9.2.0 and less than 9.2.4 contain a race condition in the authentication middlewares logic which may allow an unauthenticated user to query an administration endpoint under heavy load. This issue is patched in 9.2.4. There are no known workarounds.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 20, 2022Shinken Solutions Shinken Monitoring Version 2.4.3 affected is vulnerable to Incorrect Access Control.CVE-2022-37298 · Other software · Shinken-monitoring · reported by MITRECritical 9.8

    Shinken Solutions Shinken Monitoring Version 2.4.3 affected is vulnerable to Incorrect Access Control. The SafeUnpickler class found in shinken/safepickle.py implements a weak authentication scheme when unserializing objects passed from monitoring nodes to the Shinken monitoring server.

    Product
    Shinken Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 the Sentilo Proxy is prone to reflected XSS which only affects the SentiloCVE-2022-28816 · Other software · Carlo Gavazzi · reported by info@cert.vde.comMedium 6.1

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 the Sentilo Proxy is prone to reflected XSS which only affects the Sentilo service.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 the Sentilo Proxy server was discovered to contain a SQL injection vulneraCVE-2022-28815 · Other software · Carlo Gavazzi · reported by info@cert.vde.comLow 2.7

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 the Sentilo Proxy server was discovered to contain a SQL injection vulnerability allowing an attacker to query other tables of the Sentilo service.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 was discovered to be vulnerable to a relative path traversal vulnerability whCVE-2022-28814 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.8

    Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 was discovered to be vulnerable to a relative path traversal vulnerability which enables remote attackers to read arbitrary files and gain full control of the device.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of an SQL-injection to gCVE-2022-28813 · Other software · Carlo Gavazzi · reported by info@cert.vde.comHigh 7.5

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of an SQL-injection to gain access to a volatile temporary database with the current states of the device.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentialCVE-2022-28812 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.8

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could utilize an improper input validatCVE-2022-28811 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.8

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could utilize an improper input validation on an API-submitted parameter to execute arbitrary OS commands.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a missing authentication allows for full access via API.CVE-2022-22526 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.8

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a missing authentication allows for full access via API.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 an remote attacker with admin rights could execute arbitrary commands due CVE-2022-22525 · Other software · Carlo Gavazzi · reported by info@cert.vde.comHigh 7.2

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 an remote attacker with admin rights could execute arbitrary commands due to missing input sanitization in the backup restore function

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 an unauthenticated remote attacker could utilize a SQL-Injection vulnerabiCVE-2022-22524 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.4

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 an unauthenticated remote attacker could utilize a SQL-Injection vulnerability to gain full database access, modify users and stop services .

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022An improper authentication vulnerability exists in the Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 Web-App which allows aCVE-2022-22523 · Other software · Carlo Gavazzi · reported by info@cert.vde.comHigh 7.5

    An improper authentication vulnerability exists in the Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 Web-App which allows an authentication bypass to the context of an unauthorised user if free-access is disabled.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 28, 2022In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentialCVE-2022-22522 · Other software · Carlo Gavazzi · reported by info@cert.vde.comCritical 9.8

    In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain full access to the device.

    Product
    UWP 3.0 Monitoring Gateway and Controller
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 22, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-36062 · Other software · grafana · reported by GitHubHigh 7.6

    Grafana is an open-source platform for monitoring and observability. In versions prior to 8.5.13, 9.0.9, and 9.1.6, Grafana is subject to Improper Preservation of Permissions resulting in privilege escalation on some folders where Admin is the only used permission. The vulnerability impacts Grafana instances where RBAC was disabled and enabled afterwards, as the migrations which are translating legacy folder permissions to RBAC permissions do not account for the scenario where the only user permission in the folder is Admin, as a result RBAC adds permissions for Editors and Viewers which allow them to edit and view folders accordingly. This issue has been patched in versions 8.5.13, 9.0.9, and 9.1.6. A workaround when the impacted folder/dashboard is known is to remove the additional permissions manually.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 20, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-35957 · Other software · grafana · reported by GitHubMedium 6.6

    Grafana is an open-source platform for monitoring and observability. Versions prior to 9.1.6 and 8.5.13 are vulnerable to an escalation from admin to server admin when auth proxy is used, allowing an admin to take over the server admin account and gain full control of the grafana instance. All installations should be upgraded as soon as possible. As a workaround deactivate auth proxy following the instructions at: https://grafana.com/docs/grafana/latest/setup-grafana/configure-security/configure-authentication/auth-proxy/

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 29, 2022Hitachi Kokusai Electric Newtork products for monitoring system (Camera, Decoder and Encoder) and below allows attckers to perform a directory traversal via a cCVE-2022-37681 · Other software · Hitachi · reported by hirt@hitachi.co.jpHigh 7.5

    Hitachi Kokusai Electric Newtork products for monitoring system (Camera, Decoder and Encoder) and below allows attckers to perform a directory traversal via a crafted GET request to the endpoint /ptippage.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue.

    Product
    Hc-ip9100hd Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 29, 2022An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellCVE-2022-37680 · Other software · Hitachi · reported by hirt@hitachi.co.jpHigh 7.5

    An improper authentication for critical function issue in Hitachi Kokusai Electric Network products for monitoring system (Camera, Decoder and Encoder) and bellow allows attckers to remotely reboot the device via a crafted POST request to the endpoint /ptipupgrade.cgi. Security information ID hitachi-sec-2022-001 contains fixes for the issue.

    Product
    Hc-ip9100hd Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 16, 2022In Splunk Enterprise and Universal Forwarder versions in the following table, indexing a specially crafted ZIP file using the file monitoring input can result iCVE-2022-37439 · Other software · Splunk · reported by prodsec@splunk.comMedium 5.5

    In Splunk Enterprise and Universal Forwarder versions in the following table, indexing a specially crafted ZIP file using the file monitoring input can result in a crash of the application. Attempts to restart the application would result in a crash and would require manually removing the malformed file.

    Product
    Splunk Enterprise
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 26, 2022The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded creCVE-2022-29953 · Other software · Bakerhughes · reported by MITRECritical 9.8

    The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.

    Product
    Bently Nevada 3701/40 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 26, 2022Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication.CVE-2022-29952 · Other software · Bakerhughes · reported by MITRECritical 9.1

    Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

    Product
    Bently Nevada 3701/40 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2022The export function in SoftGuard Web (SGW) before 5.1.5 allows directory traversal to read an arbitrary local file via export or man.tcl.CVE-2022-31202 · Other software · Monitoringsoft · reported by MITREMedium 6.5

    The export function in SoftGuard Web (SGW) before 5.1.5 allows directory traversal to read an arbitrary local file via export or man.tcl.

    Product
    Softguard Web
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 17, 2022SoftGuard Web (SGW) before 5.1.5 allows HTML injection.CVE-2022-31201 · Other software · Monitoringsoft · reported by MITREMedium 5.4

    SoftGuard Web (SGW) before 5.1.5 allows HTML injection.

    Product
    Softguard Web
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-31107 · Other software · grafana · reported by GitHubHigh 7.1

    Grafana is an open-source platform for monitoring and observability. In versions 5.3 until 9.0.3, 8.5.9, 8.4.10, and 8.3.10, it is possible for a malicious user who has authorization to log into a Grafana instance via a configured OAuth IdP which provides a login name to take over the account of another user in that Grafana instance. This can occur when the malicious user is authorized to log in to Grafana via OAuth, the malicious user's external user id is not already associated with an account in Grafana, the malicious user's email address is not already associated with an account in Grafana, and the malicious user knows the Grafana username of the target user. If these conditions are met, the malicious user can set their username in the OAuth provider to that of the target user, then go through the OAuth flow to log in to Grafana. Due to the way that external and internal user accounts are linked together during login, if the conditions above are all met then the malicious user will be able to log in to the target user's Grafana account. Versions 9.0.3, 8.5.9, 8.4.10, and 8.3.10 contain a patch for this issue. As a workaround, concerned users can disable OAuth login to their Gra

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-31097 · Other software · grafana · reported by GitHubHigh 7.3

    Grafana is an open-source platform for monitoring and observability. Versions on the 8.x and 9.x branch prior to 9.0.3, 8.5.9, 8.4.10, and 8.3.10 are vulnerable to stored cross-site scripting via the Unified Alerting feature of Grafana. An attacker can exploit this vulnerability to escalate privilege from editor to admin by tricking an authenticated admin to click on a link. Versions 9.0.3, 8.5.9, 8.4.10, and 8.3.10 contain a patch. As a workaround, it is possible to disable alerting or use legacy alerting.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 30, 2022IBM CloudPak for Multicloud Monitoring 2.0 and 2.3 has a few containers running in privileged mode which is vulnerable to host information leakage or destructioCVE-2021-38941 · Other software · IBM · reported by psirt@us.ibm.comHigh 8.1

    IBM CloudPak for Multicloud Monitoring 2.0 and 2.3 has a few containers running in privileged mode which is vulnerable to host information leakage or destruction if unauthorized access to these containers could execute arbitrary commands. IBM X-Force ID: 211048.

    Product
    Cloud Pak for Multicloud Management Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 20, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-29170 · Other software · grafana · reported by GitHubMedium 6.6

    Grafana is an open-source platform for monitoring and observability. In Grafana Enterprise, the Request security feature allows list allows to configure Grafana in a way so that the instance doesn’t call or only calls specific hosts. The vulnerability present starting with version 7.4.0-beta1 and prior to versions 7.5.16 and 8.5.3 allows someone to bypass these security configurations if a malicious datasource (running on an allowed host) returns an HTTP redirect to a forbidden host. The vulnerability only impacts Grafana Enterprise when the Request security allow list is used and there is a possibility to add a custom datasource to Grafana which returns HTTP redirects. In this scenario, Grafana would blindly follow the redirects and potentially give secure information to the clients. Grafana Cloud is not impacted by this vulnerability. Versions 7.5.16 and 8.5.3 contain a patch for this issue. There are currently no known workarounds.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 18, 2022Screen Creator Advance2, HMI GC-A2 series, and Real time remote monitoring and control tool Screen Creator Advance2 versions prior to Ver.0.1.1.3 Build01, HMI GCVE-2022-29518 · Other software · KOYO ELECTRONICS INDUSTRIES CO., LTD. · reported by vultures@jpcert.or.jpHigh 7

    Screen Creator Advance2, HMI GC-A2 series, and Real time remote monitoring and control tool Screen Creator Advance2 versions prior to Ver.0.1.1.3 Build01, HMI GC-A2 series(GC-A22W-CW, GC-A24W-C(W), GC-A26W-C(W), GC-A24, GC-A24-M, GC-A25, GC-A26, and GC-A26-J2), and Real time remote monitoring and control tool(Remote GC) allows a local attacker to bypass authentication due to the improper check for the Remote control setting's account names. This may allow attacker who can access the HMI from Real time remote monitoring and control tool may perform arbitrary operations on the HMI. As a result, the information stored in the HMI may be disclosed, deleted or altered, and/or the equipment may be illegally operated via the HMI.

    Product
    Screen Creator Advance2, HMI GC-A2 series, and Real time remote monitoring and control tool
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 16, 2022ULeak Security & Monitoring: Does not have authorisation and CSRF checksCVE-2022-1557 · WordPress plugins & themes · reported by WPScanMedium 5.4

    The ULeak Security & Monitoring WordPress plugin through 1.2.3 does not have authorisation and CSRF checks when updating its settings, and is also lacking sanitisation as well as escaping in some of them, which could allow any authenticated users such as subscriber to perform Stored Cross-Site Scripting attacks against admins viewing the settings

    Product
    ULeak Security & Monitoring
    Affected
    up to 1.2.3
    What to do
    Affects up to 1.2.3. Update ULeak Security & Monitoring to the newest version and check its changelog mentions this fix; if there isn’t one yet, deactivate it until there is.
  • May 11, 2022An attacker with access to a malicious hypervisor may be able to infer data values used in a SEV guest on AMD CPUs by monitoring ciphertext values over time.CVE-2021-46744 · Other software · AMD · reported by psirt@amd.comMedium 6.5

    An attacker with access to a malicious hypervisor may be able to infer data values used in a SEV guest on AMD CPUs by monitoring ciphertext values over time.

    Product
    AMD Processors
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 6, 2022The Monitoring Console app configured in Distributed mode allows for a Reflected XSS in a query parameter in Splunk Enterprise versions before 8.1.4.CVE-2022-27183 · Other software · Splunk · reported by prodsec@splunk.comHigh 8.8

    The Monitoring Console app configured in Distributed mode allows for a Reflected XSS in a query parameter in Splunk Enterprise versions before 8.1.4. The Monitoring Console app is a bundled app included in Splunk Enterprise, not for download on SplunkBase, and not installed on Splunk Cloud Platform instances. Note that the Cloud Monitoring Console is not impacted.

    Product
    Splunk Enterprise
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 21, 2022A vulnerability in Kibana could expose sensitive information related to Elastic Stack monitoring in the Kibana page source.CVE-2022-23711 · Other software · Elastic · reported by security@elastic.coMedium 5.3

    A vulnerability in Kibana could expose sensitive information related to Elastic Stack monitoring in the Kibana page source. Elastic Stack monitoring features provide a way to keep a pulse on the health and performance of your Elasticsearch cluster. Authentication with a vulnerable Kibana instance is not required to view the exposed information. The Elastic Stack monitoring exposure only impacts users that have set any of the optional monitoring.ui.elasticsearch.* settings in order to configure Kibana as a remote UI for Elastic Stack Monitoring. The same vulnerability in Kibana could expose other non-sensitive application-internal information in the page source.

    Product
    kibana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 12, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-24812 · Other software · grafana · reported by GitHubHigh 8

    Grafana is an open-source platform for monitoring and observability. When fine-grained access control is enabled and a client uses Grafana API Key to make requests, the permissions for that API Key are cached for 30 seconds for the given organization. Because of the way the cache ID is constructed, the consequent requests with any API Key evaluate to the same permissions as the previous requests. This can lead to an escalation of privileges, when for example a first request is made with Admin permissions, and the second request with different API Key is made with Viewer permissions, the second request will get the cached permissions from the previous Admin, essentially accessing higher privilege than it should. The vulnerability is only impacting Grafana Enterprise when the fine-grained access control beta feature is enabled and there are more than one API Keys in one organization with different roles assigned. All installations after Grafana Enterprise v8.1.0-beta1 should be upgraded as soon as possible. As an alternative, disable fine-grained access control will mitigate the vulnerability.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 6, 2022Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring.CVE-2020-27374 · Other software · Drtrustusa · reported by MITREHigh 7.5

    Dr Trust USA iCheck Connect BP Monitor BP Testing 118 1.2.1 is vulnerable to a Replay Attack to BP Monitoring.

    Product
    Icheck Connect BP Monitor BP Testing 118 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 10, 2022The SAP Focused Run (Real User Monitoring) - versions 200, 300, REST service does not sufficiently sanitize the input name of the file using multipart/form-dataCVE-2022-24399 · Network & remote access · SAP SE · reported by cna@sap.comMedium 6.1

    The SAP Focused Run (Real User Monitoring) - versions 200, 300, REST service does not sufficiently sanitize the input name of the file using multipart/form-data, resulting in Cross-Site Scripting (XSS) vulnerability.

    Product
    SAP Focused Run (Real User Monitoring)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 8, 2022Icinga Web 2 is an open source monitoring web interface, framework and command-line interface.CVE-2022-24716 · Other software · Icinga · reported by GitHubHigh 7.5

    Icinga Web 2 is an open source monitoring web interface, framework and command-line interface. Unauthenticated users can leak the contents of files of the local system accessible to the web-server user, including `icingaweb2` configuration files with database credentials. This issue has been resolved in versions 2.9.6 and 2.10 of Icinga Web 2. Database credentials should be rotated.

    Product
    icingaweb2
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 8, 2022Icinga Web 2 is an open source monitoring web interface, framework and command-line interface.CVE-2022-24715 · Other software · Icinga · reported by GitHubHigh 8.5

    Icinga Web 2 is an open source monitoring web interface, framework and command-line interface. Authenticated users, with access to the configuration, can create SSH resource files in unintended directories, leading to the execution of arbitrary code. This issue has been resolved in versions 2.8.6, 2.9.6 and 2.10 of Icinga Web 2. Users unable to upgrade should limit access to the Icinga Web 2 configuration.

    Product
    icingaweb2
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 8, 2022Icinga Web 2 is an open source monitoring web interface, framework and command-line interface.CVE-2022-24714 · Other software · Icinga · reported by GitHubMedium 5.3

    Icinga Web 2 is an open source monitoring web interface, framework and command-line interface. Installations of Icinga 2 with the IDO writer enabled are affected. If you use service custom variables in role restrictions, and you regularly decommission service objects, users with said roles may still have access to a collection of content. Note that this only applies if a role has implicitly permitted access to hosts, due to permitted access to at least one of their services. If access to a host is permitted by other means, no sensible information has been disclosed to unauthorized users. This issue has been resolved in versions 2.8.6, 2.9.6 and 2.10 of Icinga Web 2.

    Product
    icingaweb2
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 24, 2022The backend infrastructure shared by multiple mobile device monitoring services does not adequately authenticate or authorize API requests, creating an IDOR (InCVE-2022-0732 · Other software · 1Byte · reported by cret@cert.orgHigh 7.5

    The backend infrastructure shared by multiple mobile device monitoring services does not adequately authenticate or authorize API requests, creating an IDOR (Insecure Direct Object Reference) vulnerability.

    Product
    Copy9
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 14, 2022Affected versions of Atlassian Jira Server and Data Center allow unauthenticated remote attackers to toggle the Thread Contention and CPU monitoring settings viCVE-2021-43953 · Websites & servers · Atlassian · reported by security@atlassian.comMedium 4.3

    Affected versions of Atlassian Jira Server and Data Center allow unauthenticated remote attackers to toggle the Thread Contention and CPU monitoring settings via a Cross-Site Request Forgery (CSRF) vulnerability in the /secure/admin/ViewInstrumentation.jspa endpoint. The affected versions are before version 8.13.16, and from version 8.14.0 before 8.20.5.

    Product
    Jira Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 11, 2022A stored cross site scripting have been identified at the comments in the report creation due to an obsolote version of tinymce editor.CVE-2021-4035 · Other software · A3Sec · reported by cve-coordination@incibe.esLow 3.5

    A stored cross site scripting have been identified at the comments in the report creation due to an obsolote version of tinymce editor. In order to exploit this vulnerability, the attackers needs an account with enough privileges to view and edit reports.

    Product
    Wocu Monitoring
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 8, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-21713 · Other software · grafana · reported by GitHubMedium 4.3

    Grafana is an open-source platform for monitoring and observability. Affected versions of Grafana expose multiple API endpoints which do not properly handle user authorization. `/teams/:teamId` will allow an authenticated attacker to view unintended data by querying for the specific team ID, `/teams/:search` will allow an authenticated attacker to search for teams and see the total number of available teams, including for those teams that the user does not have access to, and `/teams/:teamId/members` when editors_can_admin flag is enabled, an authenticated attacker can see unintended data by querying for the specific team ID. Users are advised to upgrade as soon as possible. There are no known workarounds for this issue.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 8, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-21703 · Other software · grafana · reported by GitHubMedium 6.3

    Grafana is an open-source platform for monitoring and observability. Affected versions are subject to a cross site request forgery vulnerability which allows attackers to elevate their privileges by mounting cross-origin attacks against authenticated high-privilege Grafana users (for example, Editors or Admins). An attacker can exploit this vulnerability for privilege escalation by tricking an authenticated user into inviting the attacker as a new user with high privileges. Users are advised to upgrade as soon as possible. There are no known workarounds for this issue.

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 8, 2022Grafana is an open-source platform for monitoring and observability.CVE-2022-21702 · Other software · grafana · reported by GitHubMedium 6.5

    Grafana is an open-source platform for monitoring and observability. In affected versions an attacker could serve HTML content thru the Grafana datasource or plugin proxy and trick a user to visit this HTML page using a specially crafted link and execute a Cross-site Scripting (XSS) attack. The attacker could either compromise an existing datasource for a specific Grafana instance or either set up its own public service and instruct anyone to set it up in their Grafana instance. To be impacted, all of the following must be applicable. For the data source proxy: A Grafana HTTP-based datasource configured with Server as Access Mode and a URL set, the attacker has to be in control of the HTTP server serving the URL of above datasource, and a specially crafted link pointing at the attacker controlled data source must be clicked on by an authenticated user. For the plugin proxy: A Grafana HTTP-based app plugin configured and enabled with a URL set, the attacker has to be in control of the HTTP server serving the URL of above app, and a specially crafted link pointing at the attacker controlled plugin must be clocked on by an authenticated user. For the backend plugin resource: An attack

    Product
    grafana
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 4, 2022A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker tCVE-2022-22804 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.4

    A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)

    Product
    Ecostruxure Power Monitoring Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 4, 2022A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the CVE-2022-22727 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user�s local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)

    Product
    Ecostruxure Power Monitoring Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 4, 2022A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operCVE-2022-22726 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.5

    A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)

    Product
    Ecostruxure Power Monitoring Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 28, 2022A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload.CVE-2021-22827 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions

    Product
    Ecostruxure Power Monitoring Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 28, 2022A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload.CVE-2021-22826 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions

    Product
    Ecostruxure Power Monitoring Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.