By year
15
20
Bars are flaws published each year; the red part is the share attackers have used.
Latest high and critical flaws
- CVE-2020-25179 GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.Critical 9.8 · Dec 14, 2020
- CVE-2020-25175 GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.Critical 9.8 · Dec 14, 2020
- CVE-2020-6966 In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCritical 10 · Jan 24, 2020
- CVE-2020-6965 In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCritical 9.9 · Jan 24, 2020
- CVE-2020-6964 In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CHigh 8.6 · Jan 24, 2020
- CVE-2020-6963 In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE CCritical 10 · Jan 24, 2020
- CVE-2020-6962 In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Critical 10 · Jan 24, 2020
- CVE-2020-6961 In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Critical 10 · Jan 24, 2020
- CVE-2014-9736 GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) server keystore; (3) keyHigh 10 · Aug 4, 2015
- CVE-2014-7233 GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factory default System Utilities menu, (2) TH8740 for installation using TH8740_1High 10 · Aug 4, 2015
- CVE-2014-7232 GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user,High 10 · Aug 4, 2015
- CVE-2013-7442 GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of (1) CANal1 for the Administrator user and (2) iis for the IIS user, which has unspecifHigh 10 · Aug 4, 2015
- CVE-2013-7405 The Ad Hoc Reporting feature in GE Healthcare Centricity DMS 4.2 has a password of Never!Mind for the Administrator user, which has unspecified impact and attacHigh 10 · Aug 4, 2015
- CVE-2013-7404 GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and attack vectors.High 10 · Aug 4, 2015
- CVE-2012-6695 GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1 has a password of ddpadmin for the ddpadmin user, which has unspecified impact and attack vectors.High 10 · Aug 4, 2015
- CVE-2012-6694 GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1, and Server 4.0, has a password of 2charGE for the geservice account, which has unspecified impact and aHigh 10 · Aug 4, 2015
- CVE-2012-6693 GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read/Write) user, which High 10 · Aug 4, 2015
- CVE-2012-6660 GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrHigh 10 · Aug 4, 2015
- CVE-2011-5324 The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared useHigh 10 · Aug 4, 2015
- CVE-2011-5323 GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impHigh 10 · Aug 4, 2015
- CVE-2011-5322 GE Healthcare Centricity Analytics Server 1.1 has a default password of (1) V0yag3r for the SQL Server sa user, (2) G3car3s for the analyst user, (3) G3car3s foHigh 10 · Aug 4, 2015
- CVE-2010-5310 The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors.High 10 · Aug 4, 2015
- CVE-2010-5309 GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.High 10 · Aug 4, 2015
- CVE-2010-5308 GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via aHigh 10 · Aug 4, 2015
- CVE-2010-5307 The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) aHigh 10 · Aug 4, 2015
Part of our vulnerability database: the whole National Vulnerability Database plus CISA’s exploited list, refreshed twice a day. This is general guidance, not a review of your systems.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.